NuWaves NuPower Xtender 12B04A-27 Скачать руководство пользователя страница 9

NuPower

 

Xtender™

 

12B04A

D27

 

User

 

Manual

 

 

 

 

Rev

 

1.0

 

8

 

 

4.2

 

DC POWER 

The

 

nominal

 

supply

 

voltage

 

for

 

the

 

NuPower

 

Xtender

 

is

 

+28

 

VDC.

 

The

 

amplifier

 

module

 

is

 

able

 

to

 

support

 

operation

 

over

 

a

 

supply

 

voltage

 

range

 

of

 

+11

 

to

 

+32

 

VDC

 

with

 

minimal

 

performance

 

degradation.

 

4.3

 

GROUND 

The

 

signal

 

and

 

power

 

grounds

 

are

 

tied

 

together

 

in

 

the

 

amplifier

 

module.

 

4.4

 

RS

485 SERIAL COMMUNICATIONS 

These

 

signals

 

are

 

for

 

the

 

RS

485

 

serial

 

communications

 

with

 

the

 

NuPower

 

Xtender.

 

This

 

interface

 

is

 

described

 

in

 

Section

 

5.

 

4.5

 

TRANSMIT/RECEIVE (T/R) SOURCE OR SINK 

The

 

T/R

 

Source

 

or

 

Sink

 

line

 

is

 

configurable

 

as

 

either

 

an

 

output

 

(source)

 

or

 

an

 

input

 

(sink).

 

When

 

the

 

T/R

 

line

 

is

 

configured

 

in

 

source

 

mode,

 

the

 

Xtender

 

transmit

 

and

 

receive

 

switching

 

occurs

 

automatically,

 

based

 

on

 

the

 

T/R

 

level

 

setting

 

and

 

the

 

transceiver’s

 

transmit

 

state.

 

The

 

Xtender

 

sources

 

a

 

logic

 

signal

 

to

 

indicate

 

the

 

mode

 

(transmit

 

or

 

receive)

 

of

 

the

 

BDA.

 

A

 

logic

 

high

 

indicates

 

the

 

Xtender

 

is

 

in

 

transmit

 

mode,

 

while

 

a

 

logic

 

low

 

indicates

 

the

 

Xtender

 

is

 

in

 

receive

 

mode.

 

When

 

the

 

T/R

 

line

 

is

 

configured

 

in

 

sink

 

mode,

 

the

 

transmit

 

and

 

receive

 

switching

 

is

 

under

 

manual

 

control.

 

Applying

 

a

 

logic

 

high

 

to

 

the

 

T/R

 

line

 

places

 

the

 

Xtender

 

in

 

transmit

 

mode.

 

Likewise,

 

applying

 

a

 

logic

 

low

 

to

 

the

 

T/R

 

line

 

places

 

the

 

Xtender

 

in

 

receive

 

mode.

  

T/R

 

line

 

levels

 

can

 

be

 

configured

 

to

 

+3.3

 

VDC

 

or

 

+5

 

VDC

 

logic

 

levels.

  

This

 

I/O

 

line

 

is

 

described

 

in

 

Section

 

5.

 

 

 

Содержание NuPower Xtender 12B04A-27

Страница 1: ...WER XTENDER 12B04A D27 BIDIRECTIONAL L S BAND AMPLIFIER PART NUMBER NW BA 12B04A D27 NuWaves Engineering 132 Edison Drive Middletown Ohio 45044 PH 513 360 0800 FAX 513 539 8782 www nuwaves com product sales nuwaves com ...

Страница 2: ...rporated into the chassis Completely Characterized The NuPower Xtender family of solid state bidirectional amplifiers has been completely characterized over temperature voltage and frequency These high performance modules offer significant value for the OEM user or the Systems Integrator User Friendly Reverse voltage and over voltage protection and regulator thermal shutdown provide defenses again...

Страница 3: ... in transmit mode The integrated low noise amplifier provides a minimum of 13 dB of gain in receive mode Based on the latest Gallium Nitride GaN technology NuPower s high efficiency and 6 9 in 3 form factor make it ideal for SWaP constrained applications In addition NuPower s broadband frequency coverage supports operational flexibility NuPower Xtender bidirectional amplifiers are designed with ru...

Страница 4: ...ransmit RF Gain 15 dB typ Nominal Input Drive Level 27 dBm Maximum Input Drive Level 30 dBm Receive RF Gain 13 dB min Receive Noise Figure 3 5 dB typ T R Mode Automatic Sensing or Manual T R Line T R Switch Time 1 5 µS max Supply Voltage 11 to 32 VDC Transmit Current Consumption 2 5 A 28 VDC typ 3 2 A 28 VDC max Receive Current Consumption 100 mA 28 VDC typ Table 2 NuPower Xtender 12B04A D27 Envir...

Страница 5: ...IONS Figure 2 NuPower Xtender 12B04A D27 Mechanical Outline Table 3 NuPower Xtender 12B04A D27 Mechanical Specifications Parameter Specification RF Connectors SMA female Control Power Interface Connector 9 Pin Micro D socket Dimensions L x W x H 3 00 x 2 00 x 1 16 Weight 5 8 oz ...

Страница 6: ...eratures may require additional heat sinking to maintain a baseplate temperature below 60 C at 100 transmit duty cycle Figure 3 The NuPower PA Kit offers out of the box operation for the user The fan cooled heatsink with an AC DC adapter is shown with an example PA NuPower Xtender not shown Caution The use of external heat sinking is required especially for those applications requiring high duty c...

Страница 7: ...irectly connecting to an antenna specified for the frequency range 1 0 to 2 5 GHz Connecting to an inappropriate antenna may result in damage to the amplifier module Connecting to a proper antenna through a 50 Ω transmission line or coaxial cable Avoid using damaged cables or corroded connectors while attaching the unit to an antenna Terminating the antenna terminal into a 50 Ω power attenuator wi...

Страница 8: ... into 50 Ω otherwise the amplifier could be damaged 4 1 INTERFACE CONNECTOR The NuPower Xtender features a 9 pin Micro D interface connector for control power and ground connections Table 4 NuPower Xtender Interface Pin Out Definitions Socket No Name I 0 Description 1 2 9 V Supply I Primary Power 11 to 32 VDC 3 4 5 GND I Signal and Power Ground 6 Data TX O RS 485 Data Transmit 7 Data RX I RS 485 D...

Страница 9: ...er an output source or an input sink When the T R line is configured in source mode the Xtender transmit and receive switching occurs automatically based on the T R level setting and the transceiver s transmit state The Xtender sources a logic signal to indicate the mode transmit or receive of the BDA A logic high indicates the Xtender is in transmit mode while a logic low indicates the Xtender is...

Страница 10: ... always ignored After receiving and processing a command the NuPower Xtender sends a Carriage Return terminated string as a notification that the command was completed 5 1 SERIAL COMMANDS Serial commands are outlined in the table below Table 5 NuPower Xtender Serial Commands 5 1 1 Configuration Storage The CONSTO command is used to store current Xtender settings to the EEPROM If a value is changed...

Страница 11: ... recommended to set a lower transmit threshold control value The STAT command can be used to display the current Transmit Threshold Control value The TRLVLxxxx command is used to change the setting of the Transmit Threshold Control value The Transmit Threshold Control settings are defined as 0000 lowest Transmit Threshold Control value lowest transmit detection sensitivity 4095 highest Transmit Th...

Страница 12: ...is controlled by applying a logic high or logic low to this line Applying a logic high signal to this line enables transmit mode while applying a logic low enables receive mode Note Factory default setting is 0 Source Mode The TRVOLTx command is used to configure the input and output logic levels where x is either 0 or 1 The T R Logic Level settings are defined as 0 3 3 VDC Logic 1 5 VDC Logic Not...

Страница 13: ... disposing of a NuWaves product Do not remove the cover or any hardware Do not remove components from the circuit card assembly Do not incinerate Do not crush or shred Do not dispose of as unsorted municipal waste Do not export e waste outside of the original destination country for recycling Utilize an e Steward or ISO14001 certified e waste recycler Consider export controls during recycler selec...

Страница 14: ...and Sales Phone 513 360 0800 Email product sales nuwaves com NuWaves Home Page https www nuwaves com Product Warranty https products nuwaves com wp content uploads NuWaves_Warranty_Repair pdf 7 1 GENERAL INFORMATION Copyright 2006 2020 NuWaves Ltd All rights reserved The information contained in this user manual is copyright protected NuWaves reserves the right to make periodic modifications and p...

Отзывы: