9

 

 

5

 

SERIAL INTERFACE 

The

 

NuPower

 

Xtender

 

includes

 

an

 

RS

485

 

serial

 

interface

 

for

 

adjusting

 

linearization

 

parameters

 

via

 

a

 

serial

 

terminal

 

program,

 

such

 

as

 

Termite

.

 

The

 

serial

 

port

 

must

 

be

 

configured

 

with

 

the

 

following

 

attributes:

 

 

Baud

 

rate:

 

9600

 

bps

 

 

Data

 

bits:

 

8

 

 

Stop

 

bits:

 

1

 

 

Parity:

 

None

 

This

 

section

 

provides

 

the

 

user

 

with

 

the

 

command

 

syntax

 

necessary

 

to

 

properly

 

configure

 

the

 

bidirectional

 

amplifier

 

module

 

for

 

use.

 

All

 

commands

 

have

 

the

 

following

 

attributes:

  

 

A

 

command

 

consists

 

of

 

a

 

string

 

of

 

characters,

 

followed

 

by

 

a

 

terminating

 

Carriage

 

Return

 

character,

 

 

(hex

 

0D).

 

 

Command

 

processing

 

is

 

not

 

case

 

sensitive.

 

 

Spaces

 

are

 

always

 

allowed

 

and

 

always

 

ignored.

 

 

After

 

receiving

 

and

 

processing

 

a

 

command,

 

the

 

NuPower

 

Xtender

 

sends

 

a

 

Carriage

 

Return

 

terminated

 

string

 

as

 

a

 

notification

 

that

 

the

 

command

 

was

 

completed.

 

5.1

 

SERIAL COMMANDS 

Serial

 

commands

 

are

 

outlined

 

in

 

the

 

table

 

below.

 

Table 5: NuPower Xtender Serial Commands 

5.1.1

 

Configuration Storage 

The

 

“CONSTO”

 

command

 

is

 

used

 

to

 

store

 

current

 

Xtender

 

settings

 

to

 

the

 

EEPROM.

 

If

 

a

 

value

 

is

 

changed

 

and

 

the

 

CONSTO

 

command

 

is

 

not

 

entered,

 

the

 

Xtender

 

will

 

return

 

to

 

the

 

last

 

stored

 

setting

 

upon

 

unit

 

power

 

cycling,

 

and

 

the

 

changes

 

will

 

be

 

lost.

 

The

 

“CONDEF”

 

command

 

is

 

used

 

to

 

return

 

the

 

Xtender

 

to

 

the

 

factory

 

default

 

settings.

 

 

 

Command Function 

ICD 

Section 

CONSTO

 

Store

 

settings

 

to

 

EEPROM

 

5.1.1

 

CONDEF

 

Return

 

unit

 

to

 

factory

 

default

 

values

 

5.1.1

 

TRLVL

xxxx

 

Set

 

Transmit

 

Threshold

 

Control

 

value

 

5.1.2

 

TRMODE

x

 

Set

 

T/R

 

Mode

 

5.1.3

 

TRVOLT

x

 

Set

 

T/R

 

Voltage

 

5.1.3

 

STAT?

 

Display

 

Status

 

5.1.4

 

Содержание NuPower Xtender 12B04A-27

Страница 1: ...WER XTENDER 12B04A D27 BIDIRECTIONAL L S BAND AMPLIFIER PART NUMBER NW BA 12B04A D27 NuWaves Engineering 132 Edison Drive Middletown Ohio 45044 PH 513 360 0800 FAX 513 539 8782 www nuwaves com product sales nuwaves com ...

Страница 2: ...rporated into the chassis Completely Characterized The NuPower Xtender family of solid state bidirectional amplifiers has been completely characterized over temperature voltage and frequency These high performance modules offer significant value for the OEM user or the Systems Integrator User Friendly Reverse voltage and over voltage protection and regulator thermal shutdown provide defenses again...

Страница 3: ... in transmit mode The integrated low noise amplifier provides a minimum of 13 dB of gain in receive mode Based on the latest Gallium Nitride GaN technology NuPower s high efficiency and 6 9 in 3 form factor make it ideal for SWaP constrained applications In addition NuPower s broadband frequency coverage supports operational flexibility NuPower Xtender bidirectional amplifiers are designed with ru...

Страница 4: ...ransmit RF Gain 15 dB typ Nominal Input Drive Level 27 dBm Maximum Input Drive Level 30 dBm Receive RF Gain 13 dB min Receive Noise Figure 3 5 dB typ T R Mode Automatic Sensing or Manual T R Line T R Switch Time 1 5 µS max Supply Voltage 11 to 32 VDC Transmit Current Consumption 2 5 A 28 VDC typ 3 2 A 28 VDC max Receive Current Consumption 100 mA 28 VDC typ Table 2 NuPower Xtender 12B04A D27 Envir...

Страница 5: ...IONS Figure 2 NuPower Xtender 12B04A D27 Mechanical Outline Table 3 NuPower Xtender 12B04A D27 Mechanical Specifications Parameter Specification RF Connectors SMA female Control Power Interface Connector 9 Pin Micro D socket Dimensions L x W x H 3 00 x 2 00 x 1 16 Weight 5 8 oz ...

Страница 6: ...eratures may require additional heat sinking to maintain a baseplate temperature below 60 C at 100 transmit duty cycle Figure 3 The NuPower PA Kit offers out of the box operation for the user The fan cooled heatsink with an AC DC adapter is shown with an example PA NuPower Xtender not shown Caution The use of external heat sinking is required especially for those applications requiring high duty c...

Страница 7: ...irectly connecting to an antenna specified for the frequency range 1 0 to 2 5 GHz Connecting to an inappropriate antenna may result in damage to the amplifier module Connecting to a proper antenna through a 50 Ω transmission line or coaxial cable Avoid using damaged cables or corroded connectors while attaching the unit to an antenna Terminating the antenna terminal into a 50 Ω power attenuator wi...

Страница 8: ... into 50 Ω otherwise the amplifier could be damaged 4 1 INTERFACE CONNECTOR The NuPower Xtender features a 9 pin Micro D interface connector for control power and ground connections Table 4 NuPower Xtender Interface Pin Out Definitions Socket No Name I 0 Description 1 2 9 V Supply I Primary Power 11 to 32 VDC 3 4 5 GND I Signal and Power Ground 6 Data TX O RS 485 Data Transmit 7 Data RX I RS 485 D...

Страница 9: ...er an output source or an input sink When the T R line is configured in source mode the Xtender transmit and receive switching occurs automatically based on the T R level setting and the transceiver s transmit state The Xtender sources a logic signal to indicate the mode transmit or receive of the BDA A logic high indicates the Xtender is in transmit mode while a logic low indicates the Xtender is...

Страница 10: ... always ignored After receiving and processing a command the NuPower Xtender sends a Carriage Return terminated string as a notification that the command was completed 5 1 SERIAL COMMANDS Serial commands are outlined in the table below Table 5 NuPower Xtender Serial Commands 5 1 1 Configuration Storage The CONSTO command is used to store current Xtender settings to the EEPROM If a value is changed...

Страница 11: ... recommended to set a lower transmit threshold control value The STAT command can be used to display the current Transmit Threshold Control value The TRLVLxxxx command is used to change the setting of the Transmit Threshold Control value The Transmit Threshold Control settings are defined as 0000 lowest Transmit Threshold Control value lowest transmit detection sensitivity 4095 highest Transmit Th...

Страница 12: ...is controlled by applying a logic high or logic low to this line Applying a logic high signal to this line enables transmit mode while applying a logic low enables receive mode Note Factory default setting is 0 Source Mode The TRVOLTx command is used to configure the input and output logic levels where x is either 0 or 1 The T R Logic Level settings are defined as 0 3 3 VDC Logic 1 5 VDC Logic Not...

Страница 13: ... disposing of a NuWaves product Do not remove the cover or any hardware Do not remove components from the circuit card assembly Do not incinerate Do not crush or shred Do not dispose of as unsorted municipal waste Do not export e waste outside of the original destination country for recycling Utilize an e Steward or ISO14001 certified e waste recycler Consider export controls during recycler selec...

Страница 14: ...and Sales Phone 513 360 0800 Email product sales nuwaves com NuWaves Home Page https www nuwaves com Product Warranty https products nuwaves com wp content uploads NuWaves_Warranty_Repair pdf 7 1 GENERAL INFORMATION Copyright 2006 2020 NuWaves Ltd All rights reserved The information contained in this user manual is copyright protected NuWaves reserves the right to make periodic modifications and p...

Отзывы: