4.2

 

DC POWER 

The nominal supply voltage for the NuPower ULS-25-C01-S01 is +28 VDC; however, the amplifier module 

is able to support operation over a supply voltage range of +11 to +32 VDC. 

4.3

 

GROUND 

The signal and power grounds are tied together in the PA module.  

4.4

 

RF ENABLE 

This signal is the logic control input that designates whether the unit is in transmit or standby mode. The 

RF Enable line is pulled high internally placing the PA module in 

standby

 mode. If the pin is left floating 

(i.e. not connected), the unit will default to 

standby

 mode. 

Grounding the pin (i.e. a voltage below +0.2 VDC) places the unit in 

transmit

 mode. The user can either 

connect the RF Enable line to pins 1 & 2 on the CTRL/PWR interface connector, or an open drain logic line 

capable of sinking 500 

µ

A to place the unit in 

transmit

 mode. 

4.5

 

TEMP FLAG 

This signal is a logic level output to indicate an over-temperature condition in the NuPower ULS-25-C01-

S01. A logic high (+5 VDC)  indicates  normal operation, while a logic low (0 VDC)  indicates an over-

temperature condition. The NuPower ULS-25-C01-S01 incorporates internal logic circuitry that turns off 

the DC bias to the RF transistors.  

 

Caution:  The  amplifier  should be shut down and allowed to cool off when the over-

temperature flag is set high to avoid damage to the module. 
 
 
 

 

 

Содержание NUPOWER ULS-25-C01-S01

Страница 1: ...WERTM ULS 25 C01 S01 MINI MULTI OCTAVE POWER AMPLIFIER PART NUMBER NW PA ULS 25 C01 S01 NuWaves Engineering 132 Edison Drive Middletown Ohio 45044 PH 513 360 0800 FAX 1 800 376 2026 www nuwaves com sa...

Страница 2: ...assis Completely Characterized The NuPower family of solid state power amplifiers has been completely characterized over temperature voltage and frequency These high performance modules offer signific...

Страница 3: ...n systems The NuPower ULS 25 C01 S01 s rugged chassis allows the system integrator to easily incorporate the unit into a platform operating in harsh environments with limited space such as small Unman...

Страница 4: ...ication Operating Temperature Ambient 40 to 60 o C Operating Temperature Baseplate 40 to 85 o C Storage Temperature 55 to 85 o C Table 3 NuPower ULS 25 C01 S01 Mean Time Between Failure MTBF Condition...

Страница 5: ...L SPECIFICATIONS Figure 2 NuPower ULS 25 C01 S01 Mechanical Outline Table 4 NuPower ULS 25 C01 S01 Mechanical Specifications Parameter Specification RF Connectors SMA female Control Power Interface Co...

Страница 6: ...AC DC adapter is shown with an example PA NuPower ULS 25 C01 S01 not shown Caution The use of external heat sinking is required especially for those applications requiring high duty cycle operation e...

Страница 7: ...rroded connectors while attaching the unit to an antenna Terminating the antenna terminal into a 50 power attenuator with minimum 20 dB attenuation Connecting to a load capable of dissipating the RF p...

Страница 8: ...ch operation Table 5 depicts the pin configurations to achieve low medium and high back off settings where N C is an indication to leave the pin floating i e not connected since the pin is tied high i...

Страница 9: ...ion should always be loaded into 50 otherwise the PA could be damaged 4 1 INTERFACE CABLE HARNESS The cable harness that connects the host controller to the 9 pin Micro D connector of the NuPower ULS...

Страница 10: ...ault to standby mode Grounding the pin i e a voltage below 0 2 VDC places the unit in transmit mode The user can either connect the RF Enable line to pins 1 2 on the CTRL PWR interface connector or an...

Страница 11: ...isposing of a NuWaves product Do not remove the cover or any hardware Do not remove components from the circuit card assembly Do not incinerate Do not crush or shred Do not dispose of as unsorted muni...

Страница 12: ...ng and Sales Phone 513 360 0800 Email sales nuwaves com NuWaves Home Page http www nuwaves com Product Warranty https products nuwaves com wp content uploads NuWaves_Warranty_Repair pdf 6 1 GENERAL IN...

Отзывы: