NuPower

TM

 

12B01A

02

 

User

 

Manual

    

 

 

 

Rev

 

1.0

 

8

 

 

4.2

 

DC POWER 

The

 

nominal

 

supply

 

voltage

 

for

 

the

 

NuPower

 

12B01A

02

 

is

 

+28

 

VDC;

 

however,

 

the

 

amplifier

 

module

 

is

 

able

 

to

 

support

 

operation

 

over

 

a

 

supply

 

voltage

 

range

 

of

 

+11

 

to

 

+32

 

VDC.

 

 

4.3

 

GROUND 

The

 

signal

 

and

 

power

 

grounds

 

are

 

tied

 

together

 

in

 

the

 

PA

 

module.

  

 

4.4

 

RF ENABLE 

This

 

signal

 

is

 

the

 

logic

 

control

 

input

 

that

 

designates

 

whether

 

the

 

unit

 

is

 

in

 

transmit

 

or

 

standby

 

mode.

 

The

 

RF

 

Enable

 

line

 

is

 

pulled

 

high

 

internally

 

placing

 

the

 

PA

 

module

 

in

 

standby

 

mode.

 

If

 

the

 

pin

 

is

 

left

 

floating

 

(i.e.

 

not

 

connected),

 

the

 

unit

 

will

 

default

 

to

 

standby

 

mode.

 

Grounding

 

the

 

pin

 

(i.e.

 

a

 

voltage

 

below

 

+0.2

 

VDC)

 

places

 

the

 

unit

 

in

 

transmit

 

mode.

 

The

 

user

 

can

 

either

 

connect

 

the

 

RF

 

Enable

 

line

 

to

 

pins

 

3

 

&

 

4

 

on

 

the

 

CTRL/PWR

 

interface

 

connector,

 

or

 

an

 

open

 

drain

 

logic

 

line

 

capable

 

of

 

sinking

 

500

 

µ

A

 

to

 

place

 

the

 

unit

 

in

 

transmit

 

mode.

 

 

4.5

 

TEMP FLAG 

This

 

signal

 

is

 

a

 

logic

 

level

 

output

 

to

 

indicate

 

an

 

over

temperature

 

condition

 

in

 

the

 

NuPower

 

12B01A

02.

 

A

 

logic

 

high

 

(+5

 

VDC)

 

indicates

 

normal

 

operation,

 

while

 

a

 

logic

 

low

 

(0

 

VDC)

 

indicates

 

an

 

over

temperature

 

condition.

 

The

 

NuPower

 

12B01A

02

 

incorporates

 

internal

 

logic

 

circuitry

 

that

 

turns

 

off

 

the

 

DC

 

bias

 

to

 

the

 

RF

 

transistors.

  

 

Caution:

 

The

 

amplifier

 

should

 

be

 

shut

 

down

 

and

 

allowed

 

to

 

cool

 

off

 

when

 

the

 

over

temperature

 

flag

 

is

 

set

 

high

 

to

 

avoid

 

damage

 

to

 

the

 

module.

 

 
 

 

 

Содержание NUPOWER 12B01A-02

Страница 1: ...USER MANUAL NUPOWERTM 12B01A 02 L BAND POWER AMPLIFIER PART NUMBER NW PA 12B01A 02 NuWaves Engineering 132 Edison Drive Middletown Ohio 45044 PH 513 360 0800 www nuwaves com product sales nuwaves com ...

Страница 2: ...is Completely Characterized The NuPower family of solid state power amplifiers has been completely characterized over temperature voltage and frequency These high performance modules offer significant value for the OEM user or the Systems Integrator User Friendly Reverse Voltage Over Voltage protection and regulator thermal shutdown provide defenses against user interface issues High Reliability N...

Страница 3: ...MHz NuPower PAs feature over voltage and reverse voltage protection in addition to a simple control line interface allowing the user to easily place the module into transmit or standby mode of operation A kit is available for purchase which includes a fan cooled heatsink with AC DC power adapter and upgraded interface cable with labeled banana plugs Figure 1 NuPower 12B01A 02 Functional Diagram 2 ...

Страница 4: ...ns Operating Conditions Specification Operating Temperature for Continuous Operation 5 minutes 30 to 55 o C ambient 30 to 60 o C baseplate Operating Temperature for 20 Duty Cycle 30 to 60 o C ambient 30 to 65 o C baseplate Storage Temperature 40 to 85 o C Table 3 NuPower 12B01A 02 Mean Time Between Failure MTBF Conditions Hours Ground Benign GB 126 690 Airborne Inhabited Cargo AIC 14 800 Airborne ...

Страница 5: ...AL SPECIFICATIONS Figure 2 NuPower 12B01A 02 Mechanical Outline Table 4 NuPower 12B01A 02 Mechanical Specifications Parameter Specification RF Connectors SMA female Control Power Interface Connector 9 Pin Micro D socket Dimensions L x W x H 3 00 x 2 00 x 0 65 Weight 3 7 oz ...

Страница 6: ...AC DC adapter is shown with an example PA NuPower 12B01A 02 not shown Caution The use of external heat sinking is required especially for those applications requiring high duty cycle operation e g continuous wave or for extended on time testing Operation without a proper heat sink under these conditions will cause permanent damage to the product and will void the product warranty The external heat...

Страница 7: ...Connecting to a proper antenna through a 50 Ω transmission line or coaxial cable Avoid using damaged cables or corroded connectors while attaching the unit to an antenna Terminating the antenna terminal into a 50 Ω power attenuator with minimum 20 dB attenuation Connecting to a load capable of dissipating the RF power from the PA module Loads capable of handling 20 Watts min are recommended 3 3 PO...

Страница 8: ...r is the antenna connection This connection should always be loaded into 50 Ω otherwise the PA could be damaged 4 1 INTERFACE CABLE HARNESS The cable harness that connects the host controller to the 9 pin Micro D connector of the NuPower 12B01A 02 is made up of 9 wires Table 5 NuPower 12B01A 02 Interface Pin Out Definitions Pin No Pin Name I 0 Description 1 2 V Supply I Primary Power 11 to 32 VDC ...

Страница 9: ...fault to standby mode Grounding the pin i e a voltage below 0 2 VDC places the unit in transmit mode The user can either connect the RF Enable line to pins 3 4 on the CTRL PWR interface connector or an open drain logic line capable of sinking 500 µA to place the unit in transmit mode 4 5 TEMP FLAG This signal is a logic level output to indicate an over temperature condition in the NuPower 12B01A 0...

Страница 10: ...posing of a NuWaves product Do not remove the cover or any hardware Do not remove components from the circuit card assembly Do not incinerate Do not crush or shred Do not dispose of as unsorted municipal waste Do not export e waste outside of the original destination country for recycling Utilize an e Steward or ISO14001 certified e waste recycler Consider export controls during recycler selection...

Страница 11: ... and Sales Email product sales nuwaves com Phone 513 360 0800 NuWaves Home Page https www nuwaves com Product Warranty https nuwaves com wp content uploads NuWaves_Warranty_Repair pdf 6 1 GENERAL INFORMATION Copyright 2006 2020 NuWaves Ltd All rights reserved The information contained in this user manual is copyright protected NuWaves reserves the right to make periodic modifications and product i...

Отзывы: