NuPower
TM
12B01A
‐
02
User
Manual
Rev
1.0
3
Parameter
Specification
Supply
Voltage
+11
to
+32
VDC
Current
Consumption
2.0
A
@
+28
VDC
(typ)
Power
Amplifier
Enable
GND
On
Nominal
Input
Drive
Level
0
dBm
Maximum
Input
Drive
Level
(No
damage)
+10
dBm
Impedance
50
Ω
Table 2: NuPower 12B01A
‐
02 Environmental Specifications
Operating Conditions
Specification
Operating
Temperature
for
Continuous
Operation
(>5
minutes)
‐
30
to
+55
o
C
(ambient)
‐
30
to
+60
o
C
(baseplate)
Operating
Temperature
for
20%
Duty
Cycle
‐
30
to
+60
o
C
(ambient)
‐
30
to
+65
o
C
(baseplate)
Storage
Temperature
‐
40
to
+85
o
C
Table 3: NuPower 12B01A
‐
02 Mean Time Between Failure (MTBF)
Conditions
Hours
Ground
Benign
(GB)
126,690
Airborne
Inhabited
Cargo
(AIC)
14,800
Airborne
Inhabited
Fighter
(AIF)
10,650
Airborne
Uninhabited
Cargo
(AUC)
8,400
Airborne
Uninhabited
Fighter
(AUF)
5,800