Mini57
Apr. 06, 2017
Page 417 of 475
Rev.1.00
MINI5
7
S
E
RI
E
S
TECH
NIC
A
L R
E
F
E
RE
N
CE
MA
N
UA
L
[1]
STARIEN
Start Condition Received Interrupt Enable Bit
This bit enables the generation of a protocol interrupt if a start condition is detected.
0 = The start condition interrupt Disabled.
1 = The start condition interrupt Enabled.
[0]
TOIEN
Time-out Interrupt Enable Bit
In I
2
C protocol, this bit enables the interrupt generation in case of a time-out event.
0 = The time-out interrupt Disabled.
1 = The time-out interrupt Enabled.