INSTALLATION 

STEP 1:

 Determine the placement of the amplifier. Consider the following:

•  The need to place the amplifier in a rack or on a shelf.
•  The number of subwoofers being connected to the amplifier.
•  The minimum amount of space required around the amplifier to allow for adequate cooling and ventilation. 
•  The need to access the adjustment controls to fine-tune your amplifier.

STEP 2:

  Confirm the voltage setting for your application. The indented end of the voltage selector switch should be under the screw above the appropriately 

labeled voltage level. If you need to change the voltage setting:

a.  Loosen the screws securing the voltage selector switch cover.
b.  Slide the cover up and move the switch so that the indented end of the switch is under the screw above the correct voltage level label.
c.  Slide the cover down and re-tighten the screws.

STEP 3:

  Connect the receiver to the amplifier using option a, option b, option c, or option d (depending on your receiver): 

NOTE: 

 Use the highest quality cables and connectors possible for low impedance.  

Use of a minimum of 16-gauge, stranded speaker cable is recommended.

IMPORTANT: 

 Before proceeding with these instructions, make sure the power is off to the amplifier.  

Do NOT connect the power cord until all connections are complete.

a. 

Use a line-level RCA cable connection (applicable to all models) See Fig. 4 

 

– Run the cable from the right channel of the RCA output port on the receiver to the right channel, 

low-level input port on the amplifier.

 

– Run the cable from the left channel of the RCA output port on the receiver to the left channel 

input port on the amplifier. 

~or~

b.  Use the LFE connection (applicable to all models) See Fig. 5:

  

Run the cable from the SUB RCA output port on the receiver to the LFE input port on the amplifier.

~or~

c.  Use a high-level in connection (for NV-SUBAMP100-xx models) See Fig. 6

:

 

1.  Strip approximately 1/4 n. (6.4 mm) of insulation from the inner conductor wire.

2.  Terminate the speaker wire into the modular plug.

3.  Insert the plug into the appropriate zone output on the back panel.

IMPORTANT: 

 Be careful not to let the exposed speaker wires touch. This will short the connection and could damage  

the amplifier

~or~

d.  Use a 12 V trigger connection (for NV-SUBAMP200-xx and NV-SUBAMP500 models) See Fig. 7

:

 

 

– Run the 12 V trigger connection from the output of the device to the 12 V trigger input of  

the amplifier.

 

– If using a 12 V power supply plugged into an outlet on the receiver, connect the wires to  

the trigger terminals.

 

– When using a Nuvo wireless subwoofer connection kit,  

you can modify the USB power cable for the receiver by  

following the cable pin out chart.

Pin

Name

Wire Color

Description

1

V

BUS

Red

+5 V

2

D-

White

Data-

3

D+

Green

Data+

4

ID

No Wire

On-The-Go

 ID distinguishes cable ends:

•  "A" plug (host): connected to GND

•  "B" plug (device): not connected

5

GND

Black

Signal ground

SUB

L

R

LS

CEN

RS

+12V Out

Switched Outlet

Fig. 4 

SUB

L

R

LS

CEN

RS

+12V Out

Switched Outlet

Fig. 5 

+12V Out

Switched Outlet

Fig. 6 

SUB

L

R

LS

CEN

+12V Out

RS

Switched Outlet

Fig. 7 

1  2  3  4  5

Содержание NV-SUBAMP100 Series

Страница 1: ...AMP200 xx 19 5 12 11 10 20 7 16 17 8 6 21 4 15 Fig 2 NV SUBAMP500 xx NOTE Power mode Volume control Phase control and Crossover control are accessed on the LCD display menu using the control knob 19 2...

Страница 2: ...g Subwoofer Amplifiers These amplifiers offer a substantial amount of dynamic power to increase the quality of your audio system UNDERSTANDING THE LCD PANEL FEATURES FOR NV SUBAMP500 XX MODELS Power U...

Страница 3: ...the following options Switch The amplifier is always on This is the default setting 12 V Trigger The amplifier turns on automatically upon receiving a 12 V input signal When the 12 V signal is remove...

Страница 4: ...on the receiver to the right channel low level input port on the amplifier Run the cable from the left channel of the RCA output port on the receiver to the left channel input port on the amplifier o...

Страница 5: ...ion repeat steps 1 5 for the SUB 2 side of the SUB screw terminals NOTE Expanding beyond the connection of one subwoofer will affect impedance Make sure that the total impedance of SUB 1 SUB 2 is a mi...

Страница 6: ...LFE If using line level RCA cable connections reference your subwoofer specifications and set the amplifier to the low end frequency limit of the subwoofer A 60 Hz 80 Hz range is the typical setting...

Страница 7: ...6 67 in 170 mm 2 0 in 50 5 mm 8 0 in 204 mm 16 9 in 428 mm 16 9 in 428 mm 7 5 in 191 mm 7 1 in 181 mm 8 1 in 206 mm 8 1 in 206 mm 4 5 in 114 mm 1 75 in 44 5 mm 1 75 in 44 5 mm NV SUBAMP100 xx NV SUBAM...

Страница 8: ...B Line Input Impedance 15 kOhm 15 kOhm 15 kOhm Regulatory Approvals Safety cTUVus CE LVD UL62368 CB IEC62368 SAA Aus NZ RCM Aus NZ cTUVus CE LVD UL62368 CB IEC62368 SAA Aus NZ RCM Aus NZ cTUVus CE LVD...

Страница 9: ...t nuvotechnologies com Clavardage www legrand us on q Cliquez sur l ic ne pour ouvrir une bo te de dialogue 2 Dieses Dokument enth lt wichtige Produktinformationen in Bezug auf die Sicherheit und die...

Страница 10: ...ision Interference This audio equipment generates uses and can radiate radio frequency energy If it is not installed and used properly that is in strict accordance with Nuvo s instructions it may caus...

Страница 11: ...il ne doit pas produire de brouillage et 2 l utilisateur de l appareil doit accepter tout brouillage radio lectrique subi m me si le brouillage est susceptible d en compromettre le fonctionnement Les...

Страница 12: ...tion of Conformity is available at www legrand us aboutus sustainability high performance buildings eco iconography aspx This equipment can be used in the following countries AT BG BE CY CZ DK EE FI F...

Страница 13: ...e earthing connection 10 Informations importantes de s curit Fran ais 1 Lire ces instructions 2 Conserver ces instructions 3 Respecter ces avertissements 4 Suivre toutes les instructions 5 Ne pas util...

Страница 14: ...utzbar sein 14 Eine Vorrichtung in CLASS I Fertigung sollte an einen Netzstecker mit Schutzleiteranschluss angeschlossen werden 12 lnformazioni importanti sulla sicurezza Italiano 1 Leggere queste ist...

Страница 15: ...deve ser ligado sa da da tomada de REDE com uma liga o de prote o terra 14 Informatci n lmportante de Seguridad Espanol 1 Leer estas instrucciones 2 Guardar estas instrucciones 3 Prestar atenci n a to...

Страница 16: ...point designated by local authorities Some collection points accept products for free The separate collection and recycling of your product at the time of disposal will help conserve natural resource...

Отзывы: