Nuvo Cocerto NV-I8GXS Скачать руководство пользователя страница 2

ENGLISH

Danger
Exposure to extremely high noise levels may cause a permanent 
hearing loss. Individuals vary considerably to noise induced hearing 
loss but nearly everyone will lose some hearing if exposed to sufficiently 
intense noise for a sufficient time. The U.S. Government's 
Occupational Safety and Health Administration (OSHA) has specified 
the following permissible noise level exposures: 

According to OSHA, any exposure in the above permissible limits could 
result in some hearing loss. Ear plugs or protectors in the ear canal or over 
the ears must be worn when operating this amplification system in order to 
prevent a permanent hearing loss. If exposure in excess of the limits as 
put forth above, to insure against potentially harmful exposure to high 
sound pressure levels, it is recommended that all persons exposed to 
equipment capable of inducing high sound pressure levels, such as this 
amplification system, be protected by hearing protectors while this unit is in 
operation.

DURATION PER DAY (HOURS)    8    6    4    3    2     1

SOUND LEVEL (dB)                       90  93   95  97 100  103

THIS SYMBOL IS INTENDED TO ALERT THE USER TO THE PRESENCE 
OF NON-INSULATED  "DANGEROUS VOLTAGE" WITHIN THE 
PRODUCT'S ENCLOSURE THAT MAY BE OF SUFFICIENT MAGNITUDE 
TO CONSTITUTE  A RISK OF ELECTRIC SHOCK TO PERSONS.

THIS SYMBOL IS INTENDED TO ALERT THE USER TO THE PRESENCE 
OF IMPORTANT OPERATING AND MAINTENANCE (SERVICING) 
INSTRUCTIONS IN THE LITERATURE ACCOMPANYING THE UNIT.

1.  Read all safety and operating instructions before using this 

product.

2.  All safety and operating instructions should be kept for future 

reference.

3.

Read and understand all warnings listed on the operating 

instructions.

4 . Follow all operating instructions to operate this product.

5.  This product should not be used near water, i.e. bathtub, sink, 

swimming pool, wet basement, etc.

6.  Only use dry cloth to clean this product.

7.  Do not block any ventilation openings, It should not be placed flat 

against a wall or placed in a built-in enclosure that will impede the 
flow of cooling air.

8.

 Do not install this product near any heat sources ; such as, 

radiators, heat registers, stove or other apparatus (including heat 
producing amplifiers) that produce heat.

9.  Do not defeat the safety purpose of the polarized or grounding-

type plug. A polarized plug has two blades with one wider than the 
other. A grounding-type plug has two blades and a third grounding 
prong. The wide blade or the third prong are provided for your 
safety. If the provided plug does not fit into your outlet, consult an 
electrician for replacement of the obsolete outlet.

10. Protect the power cord being walked on or pinched, particularly at 

plugs, convenience receptacles and the point where they exit 
from the apparatus. Do not break the ground pin of the power 
supply cord.

11 . Only use attachments specified by the manufacturer.

12. Use only with the cart, stand, tripod, bracket, or table specified by 

the manufacturer or sold with the apparatus. When a cart is used, 
use caution when moving cart/apparatus combination to avoid 
injury from tip-over.

13. Unplug this apparatus during lightning storms or when unused for 

long periods of time.

14. Care should be taken so that objects do not fall and liquids are 

not spilled into the unit through the ventilation ports or any other 
openings.

15. Refer all servicing to qualified service personnel. Servicing is 

required when the apparatus has been damaged in any way; 
such as, power-supply cord or plug is damaged, liquid has been 
spilled or objects have fallen into the apparatus, the apparatus 
has been exposed to rain or moisture, does not operate normally 
or has been dropped.

16. WARNING: To reduce the risk of fire or electric shock, do not 

expose this apparatus to rain or moisture.

IMPORTANT SAFETY INSTRUCTIONS

RISK OF ELECTRIC SHOCK

DO NOT OPEN

CAUTION:

 TO REDUCE THE RISK OF ELECTRIC SHOCK, DO 

NOT REMOVE CHASSIS. NO USER-SERVICEABLE 
PARTS INSIDE. REFER SERVICING TO QUALIFIED 
SERVICE PERSONNEL.

AVIS:   RISQUE DE CHOC ELECTRIQUE-NE PAS OUVRIR.

CAUTION

APPARATUS SHALL NOT BE EXPOSED TO DRIPPING OR SPLASHING 
AND THAT NO OBJECTS FILLED WITH LIQUIDS, SUCH AS VASES, 
SHALL BE PLACED ON THE APPARATUS.

Содержание Cocerto NV-I8GXS

Страница 1: ......

Страница 2: ...closure that will impede the flow of cooling air 8 Do not install this product near any heat sources such as radiators heat registers stove or other apparatus including heat producing amplifiers that...

Страница 3: ...r s d eau comme par exemple baignoires viers piscine sous sol humides Etc 6 Utiliser exclusivement un chiffon sec pour nettoyer ce produit 7 Ne bloqu r aucune ouverture de ventilation Ne pas placer le...

Страница 4: ...nding Grand Concerto to 16 Zones Page 11 IX Using the Grand Concerto Configurator Software Page 11 1 Main Startup Page 11 2 IR Libraries Page 12 3 Defining Sources Page 15 4 Macros Page 16 5 Zones Pag...

Страница 5: ...The new OLED organic light emitting diode display allows up to eight lines of text for easily scrolling through music titles and menu selections Capacitive touch controls provide immediate access to t...

Страница 6: ...stereo RCA cables 4 Speaker Output Six of the Grand Concerto s eight zones are amplified These outputs accept 16 gage two conductor speaker wire and provide 40 watts per channel of power 5 Source Lin...

Страница 7: ...setting parameters 7 Power This button turns the local zone on and off and turns all zones off simultaneously 8 Play Pause This IR programmable button toggles between the play and pause functions of t...

Страница 8: ...he first twelve are directly accessible using the RC1 Favorites buttons 6 DISP This button allows access to the Display dim menu available at each Control Pad 7 Function LED This LED Light Emitting Di...

Страница 9: ...wires into the correct color scheme as shown in Fig 1 3 Flatten the wires in their correct order and trim them evenly across the top Most crimp tools have a wire trimmer built in It is best to trim th...

Страница 10: ...in and the power button on the front panel should be engaged before proceeding with the rest of the installation This activates the internal protective circuitry of the Grand Concerto System IV Insta...

Страница 11: ...corresponding audio output on the source equipment and to the desired source input on the back of the Grand Concerto amplifier The numbered input for each source is important in the configuration of t...

Страница 12: ...mands to a variety of components NuVo T2G Tuner Direct Numeric Access Fig 7 The NuVo T2G Tuners have the ability for direct IR access to numeric station tuning This can be done through the T2G remote...

Страница 13: ...OHM X2 20W 6OHM X2 SYS ON EXT MUTE L R L R L R VARIABLE OUTPUT FIXED OUTPUT SUM1 3033118 C US CONFORMS TO UL STD 6500 CERTIFIED TO CAN CSA STD E60065 NuVo Technologies Cincinnati Ohio USA FUSE T5 A 12...

Страница 14: ...see a dialog box asking if you wish to overwrite the existing file If this file is not stored in your computer this box will not appear Fig 10 Fig 12 2 1 IR Libraries Fig 11 The IR Library is a list...

Страница 15: ...above Double click on the desired component from the IR Library page This will open the IR Library Editor This window lists the complete set of functions for that type of device To initiate the IR rec...

Страница 16: ...iate the On command when a zone is turned on and in turn initiate the Off command when the zone All Off function holding the Power button for three seconds is initiated from any of the Control Pads Fi...

Страница 17: ...ource will open the Select Source window This window assigns the appropriate source number input The Display Name is the text that will be read on the Control Pad when that source is selected in any z...

Страница 18: ...ssigned Even though the components are assigned you must still set the NuVoNet source inputs on each of the components see Setting Up the T2G Tuners M3 Audio Server and NuVoDock for iPod pg 9 Fig 19 F...

Страница 19: ...o string on the right Up to 255 codes can be added to a single macro and the codes will fire in the order in which they are added to the string Once the desired macro string is complete click done and...

Страница 20: ...0 entries for zone Control Pads The system can accommodate a total of 20Control Pads by using the slave function in the Edit Zone Properties window A slave Control Pad is homerun to the EZ Port but au...

Страница 21: ...e refer to the ability to turn all zones on simultaneously In some zones you may not want this function Bass and Treble Both bass and treble can be adjusted individually on a zone by zone basis The EQ...

Страница 22: ...ds This is a useful feature for large rooms where more than one Control Pad is desired If slave Control Pads are used we suggest that you disable the IR pass through on those to prevent cross communic...

Страница 23: ...zone mute when the Control Pad power button is tapped When it is held a second menu will appear with the options to turn the zone off or turn all the zones off Tap Zone Off Hold for Group All Off Menu...

Страница 24: ...e finished configuration is now ready to be downloaded to the Grand Concerto amplifier While downloading a progress box will show download progress Once complete the configuration is permanently store...

Страница 25: ...n Within the main menu of each zone go to Setup Within the Setup options scroll to Advanced Settings and to Zone Number All the used addresses will be grayed out Any available addresses will be access...

Страница 26: ...cally reset when an All Off command is issued from a Control Pad Fig 37 Lock Zone Off Adv Zone Control Party Mode Do Not Disturb Lock Zone Sleep 90 Minutes 120 Minutes Sleep Off 15 Minutes 60 Minutes...

Страница 27: ...al favorites can be defined for easy access from within the Main Menu or from the twelve numeric favorites from the Grand Concerto remote control Any favorites which include M3 and iPod play lists tun...

Страница 28: ...ols this level Maximum Volume is an overall zone volume limit and is set in the same manner as Initial Volume Page Volume controls the level at which a page is amplified in each zone and Party Volume...

Страница 29: ...er or specific zone address This is done by scrolling to the desired zone and selecting it All used zone addresses will be grayed out If you have defined zones in the Configurator Software the actual...

Страница 30: ...six seconds before the advanced functions are accessible Fig 50 External Mute Page The EXT MUTE input on the back panel of the Grand Concerto has a dual function In normal mode it is designed for the...

Страница 31: ...uded in the Learning Station Package This will supply the necessary AC power for IR learning and testing 2 CONNECT TO PC Using one of the supplied RS232 cables connect from the RS232 port on your comp...

Страница 32: ...S232 cable to the back of the Interface box into the CONNECT TO PC input At this point it is not necessary to have the Interface box connected to the Grand Concerto amplifier When setting up a new sou...

Страница 33: ...Technologies Cincinnati Ohio USA FUSE T5 A 120V 60Hz 500W MODEL NV I8DM SIX SOURCE EIGHT ZONE AUDIO DISTRIBUTION SYSTEM www nuvotechnologies com OUTPUT POWER OUTPUT POWER OUTPUT POWER 20W 6OHM X2 20W...

Страница 34: ...N CSA STD E60065 NuVo Technologies Cincinnati Ohio USA FUSE T5 A 120V 60Hz 500W MODEL NV I8DM SIX SOURCE EIGHT ZONE AUDIO DISTRIBUTION SYSTEM www nuvotechnologies com OUTPUT POWER OUTPUT POWER OUTPUT...

Страница 35: ...ers When the zone is turned off the internal amplifier of the LSA40 is automatically engaged LSA40 Back LSA40 Front 50 Watt AC power adapter supplied with the LSA40S AC Power Source Any stereo line le...

Страница 36: ...X2 20W 6OHM X2 SYS ON EXT MUTE L L R VARIABLE OUTPUT FIXED OUTPUT SUM1 3033118 C US CONFORMS TO UL STD 6500 CERTIFIED TO CAN CSA STD E60065 NuVo Technologies Cincinnati Ohio USA FUSE T5 A 120V 60Hz 5...

Страница 37: ...eo to RCA patch cable There are two methods for triggering the P2100 from the Grand Concerto outputs One is to set the POWER MODE switch on the P2100 to AUDIO extreme left position and allow an incomi...

Страница 38: ...amplifier Outputs Power Requirements Variable output 0 600mV Power Supply 120VAC 240VAC 50 60Hz Fixed output 600mV Power Consumption all channels 600VA 480W Impedance 600 Ohms driven to full rated pow...

Страница 39: ...will display when that cable is connected to the system A damaged MCU must be replaced by NuVo With the Control Pads plugged in the POWER LED on the front of the amplifier will not turn on One or more...

Страница 40: ...gh or in the Advanced Zone Setup menu see pg 27 Remote Controls at any Control Pad you have the ability by zone to Disable the IR receiver This will prevent direct sunlight or possibly plasma and fluo...

Страница 41: ...www nuvotechnologies com NuVo Technologies LLC Hebron Kentucky USA I8G 0742...

Отзывы: