background image

WARRANTY - TERMS AND CONDITIONS

The manufacturer, distributor and all the parties involved in the sale do not assume 

any liability for losses and economic damage from any malfunction of the product. In 

accordance with current regulations the manufacturer, distributor and all the parties 

involved in the sale are not responding in any case for damages, including direct, 

indirect ones, loss of net income, loss of savings and additional damage and other 

details consequences going beyond the damage caused by the breach of warranty, 

contract, strict liability, wrongdoing or due to other causes, resulting from the use or 

inability to use the product and/or paper and electronic documents, including the lack 

of service.
For further information on the help service visit the website www.nuvitababy.com

This product benefits of a warranty of 24 months on material and manufacturing 

defects, starting from the date of purchase (see sales slip).
The warranty of 24 months does not include damages caused by the usual use of 

parties identified as “consumable” (e.g., batteries, brush heads or parts subject to usury).
The legal guarantee of 24 months is void if:

1. 

2.
3.

The product has undergone aesthetic damage due to improper use not in 

accordance with instructions in the manual.
This product has been modified and/or tampered with.
The cause of the failure was due to poor maintenance of the individual 

components and/or accessories and/or supplies (e.g. oxidation and/or scaling due 

to the retention of water or other liquids, sediment blocking the sensor, leak of 

corrosive liquid from batteries).

The following is excluded from the legal guarantee of 24 months:

1. 

2. 

 

3. 

4. 

5.

Costs related to replacements and/or repair of parts subject to wear or costs for 

ordinary maintenance of the product.
The costs and risks involved in transporting the product to and from the store 

where you purchased or otherwise authorized collection centre to receive the 

products under warranty.
Damage caused by or resulting from improper installation or improper use not in 

accordance with the directions in the instruction manual.
Damage due to natural disasters, accidental events or adverse conditions not 

compatible with the product.
Defects that have a negligible effect on product performance.

Содержание 5076

Страница 1: ...EN Portable nebuliser with MESH technology 5076...

Страница 2: ...Manufacturer Low battery indicate Power indicate light Keep away from sunlight Type BF Applied Part Read instructions carefully Keep in a cool dry place Operating instructions Symbol for the marking o...

Страница 3: ...molecular density such as drugs based on hyaluronic acid To preserve the pores of the nebulizing plate and to avoid clogging it is advisable to avoid the use of physiological hypertonic solution due t...

Страница 4: ...9 10 11 12 13 14 a b 15 Adult Mask Child Mask Adapter Optional Power Plug Adapter Connector Storage bag PREPARATION BEFORE USE Use the Battery Open the battery cover in the bottom of the main unit al...

Страница 5: ...ning and disinfecting To avoid cross infection all users of a same device should each be provided with a set of nebulizer and accessories The nebulizers and accessories for different users should be s...

Страница 6: ...left hand and close the nebuliser cover with your right hand press the lock downwards with the thumb to the point when you hear a clicking sound that indicates a good closing state 5 Reinstall the Ou...

Страница 7: ...sal cavity it is recommended to take a long breath through nasal cavity and then exhale through mouth In case of medication through throat it is recommended to take breath through mouth and then exhal...

Страница 8: ...nds depending on the liquid type When there is not much liquid left you may tilt the device towards yourself to allow liquid gathered at the nebulising head side in order to make full use of the resid...

Страница 9: ...ting the nebulising head gently clean the metal mesh and electrode in the nebulising head with a medical swab dipped with medical alcohol rinse the nebulising head with water dry the surface of nebuli...

Страница 10: ...our doctor No tap water or boiled water can be used The container for preparation of liquid must be boiling sterilised The duration limit for each use of the device should be no more than 15 minutes o...

Страница 11: ...vice does not work Incorrect installation of nebuliser Reinstall the nebuliser correctly Dirt on and in the nebuliser is serious Clean the nebuliser replace nebulising head if necessary The liquid can...

Страница 12: ...y Life 90 minutes supplied by two AA Alkaline Battery Automatic Shutdown Automatic shutdown without liquid Operating Temperature and humidity Air pressure 10 C 40 C 85 R H 700hPa to 1060hPa Storage Te...

Страница 13: ...d as consumable e g batteries brush heads or parts subject to usury The legal guarantee of 24 months is void if 1 2 3 The product has undergone aesthetic damage due to improper use not in accordance w...

Отзывы: