NUVIA HYDRO GUARD Скачать руководство пользователя страница 5

5

Use (check the sticker on the package to identify the filter 
housing model) 

 

- In case of use for the filtration of drinking water, do not use for filtration of water that 

is unsafe or of unknown quality. Systems certified for cyst reduction may be used on 
waters that contain filterable cysts.  

- Respect the working parameters shown in the label affixed to the filter housing. 
- If pressure exceeds the working conditions, protect the product with a pressure reducer. 
- Keep clear filter housings models protected from light. Use only opaque housings 

models for installation under direct light. The filter housings must be supplied with 
cold water only. 

- Protect from excessive cold or heat: do not expose to temperature below 39°F (4°C) 

or above 113°F (45°C). 

- Protect from back-flows of hot water with a non-return valve.  
- Protect from hammering with an anti-hammering device. In case of installation on 

systems powered by a pump and especially on those equipped with a pressure and 
flow controller, an additional expansion vessel must be installed upstream the filter 
to protect it from possible repeated pressure peaks. 

- Should the filter (h cartridge) be left not in use for more than 1 week replace 

cartridge/s with new one/s prior to use. 

 
 
 

 
 
 

 
 

 

Operations for the replacement  
of a filter cartridge 

See  figures and follow step-by-step  
instructions below to replace  
a filter cartridge. 

5’

 

 

The values of the maximum working temperature and the maximum 
working pressure shown in the label affixed to the filter housing are 

intended as maximum working parameters and must not be exceeded. Use 
of the filter under higher pressure conditions could cause ruptures.

D

new

new

1

4

8

9

10

5

6

7

2

3

Nuvia_3P_INSTRUCTIONS.qxp_Layout 1  10/11/21  09:22  Pagina 5

Содержание HYDRO GUARD

Страница 1: ...Nuvia_3P_INSTRUCTIONS qxp_Layout 1 10 11 21 09 22 Pagina 1...

Страница 2: ...Nuvia_3P_INSTRUCTIONS qxp_Layout 1 10 11 21 09 22 Pagina 2...

Страница 3: ...code Avoid all kind of stress by using a wall bracket Should the use of the wall bracket be impossible the installer qualified and licensed personnel shall be responsible for the most appropriate ins...

Страница 4: ...with cartridge remove the protective plastic wrap from the cartridge before the use Refer to Fig D for step by step instructions for the insertion of a new cartridge Start Up Keep the housing package...

Страница 5: ...ws of hot water with a non return valve Protect from hammering with an anti hammering device In case of installation on systems powered by a pump and especially on those equipped with a pressure and f...

Страница 6: ...d housing head Leaks in inlet outlet connections CAUSE a Housing not sufficiently tightened b O ring affected old a Not enough sealant and or connection not sufficiently tightened b Improper connectio...

Страница 7: ...lida al lado con la flecha OUT salida Figura B Conecte la tuber a usando conexiones decreciente nicamente si los filtros est n marcados como NPT y o si los filtros est n especificados como NPT en la e...

Страница 8: ...del filtro Si usa para filtraci n de agua potable no lo use para el filtrado de agua que no sea segura o de calidad desconocida Los sistemas certificados para la reducci n de quistes podr an ser usado...

Страница 9: ...de 1 semana sustituye el cartucho s por el nuevo antes del empleo Operaciones de reemplazo de Cartucho para filtros Consulte las figuras y siga las instrucciones paso a paso a continuaci n para reempl...

Страница 10: ...os 5 minutos antes de usar el agua Disposici n del filtro y del cartucho Los contenedores y los cartuchos se deben disponer de acuerdo con las reglas y las normativas vigentes Tras poner nuevamente en...

Страница 11: ...Nuvia_3P_INSTRUCTIONS qxp_Layout 1 10 11 21 09 22 Pagina 11...

Страница 12: ...Nuvia_3P_INSTRUCTIONS qxp_Layout 1 10 11 21 09 22 Pagina 12...

Отзывы: