potential.
The Cell Interface also accepts power from its Link In connector to power itself, as well as subsequent
Cell Interface modules in the Link Bus chain (i.e. connected to its Link Out connector). The amount of
current sourced into this connector is the sum of current consumed by this Cell Interface and the
subsequent Cell Interface modules in the Link Bus chain.
on the previous Cell Interface module in the Link Bus
Table 27. Link In: Molex Micro-Fit 3.0 Connector
Molex 43025-0400
Manufacturer
Molex Incorporated
Housing
43025-0400
Housing material
Nylon UL94V-0
Circuits
4
Crimp terminal
43030-0002
Wire gauge range
AWG20–24 stranded
Table 28. Link In Connector Pin Assignment
Pin
Connection
Description
Connected to Device
1
VBUS
DC power from the Stack Switchgear, with Fault Pilot
Signal
Previous Cell Interface in the Link Bus
chain or Stack Switchgear
2
COM
Power return from the Stack Switchgear
Previous Cell Interface in the Link Bus
chain or Stack Switchgear
3
IPA
Link Bus differential pair plus
Previous Cell Interface in the Link Bus
chain or Stack Switchgear
4
IMA
Link Bus differential pair minus
Previous Cell Interface in the Link Bus
chain or Stack Switchgear
8.2.4. Link Out
This interface is used to provide a data channel and power source to subsequent Cell Interface
modules in the Link Bus chain. The amount of current supplied by this connector is the sum of current
consumed by all subsequent Cell Interface modules in the Link Bus chain (up to 25 mA per CI-12 or