Table 13. Link Out: Molex Micro-Fit 3.0 Connector
Molex 43025-0400
Manufacturer
Molex Incorporated
Housing
43025-0400
Housing material
Nylon UL94V-0
Circuits
4
Crimp terminal
43030-0002
Wire gauge range
AWG20-24 stranded
Table 14. Link Out Connector Pin Assignment
Pin
Connection
Description
Connected to Device
1
VBUS
DC power from Stack Controller, with Fault
Pilot Signal
Cell Interface
2
COM
Power return from Stack Controller
Cell Interface
3
IPA
Link Bus differential pair plus
Cell Interface
4
IMA
Link Bus differential pair minus
Cell Interface
4.4.2. Link In
The Link In connector provides power and communication to this Cell Interface from the Cell Interface
modules below this Cell Interface, or from the Stack Controller if this Cell Interface is measuring the
most negative cell in the stack.
The amount of current sourced into this connector is the sum of current consumed by this Cell
Interface and all those above it (which amounts to all Cell Interface modules if this Cell Interface is
measuring Cell 1).
Connect to the Link Out connector on the Cell Interface that is measuring the previous series-
connected cell below this Cell Interface to this connector, or connect the Stack Controller to this
connector if this Cell Interface is measuring the bottom cell in the stack.
Nuvation Energy High-Voltage BMS - Installation Guide
Document ID: NE-IG-001
15
Rev 2.1, 2020-03-13