background image

www.NutrichefKitchen.com

www.NutrichefKitchen.com

PART THREE: TROUBLE SHOOTING GUIDE

1. Faucet Leakage:

Solution:

 Please screw out and remove  the faucet and     

install again, make sure the faucet matches the connection 

of spear tightly.

2. SpearCross-bar Leakage:

Solution:

 There is a nut under spear main body, tighten the 

nut to prevent leakage.

3. Too Much Foam:

Solution:

 Flow-control block would help to reduce the 

speed of beer flowing and reduce amount of foam.

If there is too much pressure, please pull on the pressure

relieving ring for a couple of seconds.

When pressure within keg reach 30PSI, the pressure 

relieving ring would release C02 automatically to keep safe.

                                                4. C02 Leakage:

                C02 capsule should be installed properly and 

tightly. 

In case there is C02 leakage, please observe the 

position of leakage and continue with the tightening 

process, but never screw out if gas remains.

PART FOUR: WARNING

1. Keep away from children under 18.

2. Never point cylinder towards someone's face.

3. Do not heat over 140°F as rupture may occur!

4. Discontinue using of this equipment if unsolvable leakage  

    or visible damage is found.

5. Capsule end become punctured when turned into  

    regulator base. Unscrewing capsule before it's empty  can  

    result in loss of high pressure gas. Please remember, never  

    unscrew the C02 capsule before gas used up, liquid C02  

   spray onto unprotected skin may cause freezing burns.

6. Exterior of capsule may become frozen when in use, this is

    normal. But don't touch with bare hands, your fingers  

    could stick to the frozen surface and cause frostbite.

7. Please ship via land or sea shipment, never bring C02  

    capsule when you travel by air.

Features

• 

Complete Stainless Steel Mini Keg System

• 

CO2 System Keeps Homebrew Fresh & Carbonated All Day

• 

Solid Stainless Steel Construction Keep Beverage Colder Longer

• 

Made of Food Grade S/S 304 Rust Proof Stainless Steel

• 

With Neoprene Sleeve

• 

CO2 Safety Pressure: 30 PSI

PKBRTP50

64 Oz Stainless Steel Complete Set Dispenser & CO2 System

Weight: 4.1 lbs.

Dimesions: 13.4 x 7.5 x 6.9 inches

PKBRTP100

128 Oz Stainless Steel Complete Set Dispenser & CO2 System

Weight: 4.80 lbs.

Dimesions: 19.5 x 7.5x 6.9 inches

                                     3. Pull on the pressure  relieving ring for a        

 

                        couple of seconds. If the keg was        

 

                        shaken in transit or warmed, it may  

 

                        contain excessive pressure which must     

 

                        be relieved before tapping. A hissing  

 

                        noise is expected.

 

 

   4. Slowly turn the regulator knob in       

 

                        clockwise direction to 5 PSI, and stop               

 

                        for 2 seconds and turn off regulator. 

    Wait for 2 mins, then pull on the pressure  relieving ring   

    for a couple of seconds. This is for adjusting pressure of  

    keg beer.

5. Put a glass or pitcher under the faucet spout,with the    

    faucet knob pulled forward (ON), slowly turn the regulator  

    knob on in clockwise direction, until beer starts to flow     

    out. Don't continue adding pressure,suggest tapping 5-8  

    PSI(max pressure 30PSI), so please stop turning the  

    regulator knob when the pressure  is enough to tap beer  

    out with perfect foam. Too much pressure  would cause  

    over foam. When the beer stopped or flow slower, try  

    turning the regulator knob on slowly, to get bigger  

    pressure.

6. When you finish  tapping, please turn regulator knob to  

    OFF position.

7. If no beer flow out,then the C02 capsule needs to be  

     replaced, unless no beer is rema ined. (Normally,16g  

    capsule can tap 4-5 liters of beer).

Caution:

 Removing a punctured capsule from regulator 

should be done slowly. Swish is expected if pressure  

remains.

8. Turn the regulator knob off 

    and install a new capsule into 

    the regulator by following 

    above steps