background image

8

9

SAFETY WARNINGS FOR 

EXTRACTING FOR SOUPS

•   WARNING!:  ONLY USE THE VENTED SOUPERBLAST PITCHER AND TWO-PIECE 

LID WHILE OPERATING THE NUTRIBULLET Rx IN SOUPERBLAST MODE. THE 
SOUPERBLAST PITCHER IS SPECIALLY VENTED TO RELEASE PRESSURE AS THE 
SOUP MIXTURE HEATS. OTHER VESSELS ARE UNVENTED AND MAY RUPTURE 
AND CAUSE PERSONAL INJURY IF MISUSED IN SOUPERBLAST MODE.

• TO PREVENT OVERHEATING: DO NOT REPEAT SOUPERBLAST MODE FOR THE SAME 

HOT SOUP. IF MORE HEAT IS REQUIRED, PLACE THE CONTENTS IN A MICROWAVE-
SAFE CONTAINER AND CONTINUE HEATING TO DESIRED TEMPERATURE. TO 
MAKE A NEW SOUP, EMPTY OLD CONTENTS, ADD NEW INGREDIENTS AND WAIT 
1 FULL MINUTE BEFORE RETURNING THE VESSEL TO THE POWER BASE TO START 
A NEW SMART TECHNOLOGY CYCLE. DO NOT REPEAT MORE THAN 2 CYCLES IN 
SOUPERBLAST MODE RESTING 1 MINUTE BETWEEN CYCLES.

• DO NOT RUN THE NUTRIBULLET IN SOUPERBLAST MODE FOR MORE THAN 2 CYCLES 

CONSECUTIVELY WITHOUT ALLOWING THE NUTRIBULLET POWER BASE AND 
SOUPERBLAST ACCESSORIES COOL OFF FOR 30-60 MIN. TO PREVENT OVERHEATING 
AND ALLOW INGREDIENTS TO SETTLE BEFORE CONTINUING TO BLEND.

•  IF POWER BASE DOES NOT SHUT OFF AFTER ONE (1) 7-MINUTE INTERVAL 

DURING SOUPERBLAST MODE, DEPRESS THE POWER BUTTON, LOCATED 90˚ TO 
THE LEFT SIDE OF THE G-BUTTON OR SIMPLY LIFT THE SOUPERBLAST PITCHER 
OFF OF THE POWER BASE.

•  ALLOW POWERBASE TO SHUT OFF COMPLETELY AFTER INITIAL INTERVAL AND 

WAIT FOR 3-4 MINUTES BETWEEN INTERVALS.

•  POWER BASE IS EQUIPPED WITH AN INTERNAL THERMAL BREAKER THAT 

SHUTS OFF THE POWER BASE WHEN THE UNIT OVERHEATS. IF THE POWERBASE 
OVERHEATS AND SHUTS OFF, UNPLUG THE POWER BASE OR PRESS THE POWER 
BUTTON, LOCATED 90˚ TO THE LEFT OF THE G-BUTTON AND LET IT COOL FOR 
AN HOUR OR MORE BEFORE ATTEMPTING TO USE IT AGAIN. POWER BASE WILL 
RESET WHEN THE UNIT IS POWERED OFF AND THE THERMAL BREAKER HAS 
COOLED DOWN SUFFICIENTLY.

HEAT CAUTION!

•  DURING SOUPERBLAST MODE, THE CONTENTS INSIDE CAN REACH UP TO  

ABOUT 70ºC / 150ºF THROUGH THE FRICTION OF THE ROTATING BLADE.

•  KEEP HANDS AND OTHER EXPOSED SKIN AWAY FROM THE LID OPENING TO 

PREVENT POSSIBLE BURNS DURING SOUPERBLAST MODE.

•  DO NOT REMOVE THE LID DURING PROCESSING OF SOUP—INGREDIENTS WILL 

BECOME HOT AND MAY SPLASH OUT AND CAUSE INJURY.

•  DO NOT TOUCH SOUPERBLAST PITCHER DIRECTLY WITH HANDS AFTER 

SOUPERBLAST MODE! THE SOUPERBLAST PITCHER SURFACE, BLADES AND 
COUPLING GEAR WILL BE HOT! 

•  ALWAYS USE APPROPRIATE HEAT RESISTANT PADS ON THE HANDLE TO HOLD THE 

SOUPERBLAST PITCHER AND TO SUPPORT THE BOTTOM OF THE CONTAINER.

•  CAREFULLY OPEN SOUPERBLAST PITCHER LID AFTER SOUPERBLAST MODE,  

AS ESCAPING STEAM AND MOISTURE MAY CAUSE SCALDING BURNS. 

•  Always attach blade to 

SouperBlast Pitcher

 and hand tighten or use the blade remover to 

tighten the blade to prevent leakage prior to adding ingredients into the pitcher.

•  

NEVER USE THE EXTRACTOR BLADE TO BLEND WITHOUT LIQUID AS DOING SO 
MAY DAMAGE THE BLADE.

•  Do not use the soup pitcher on the motor base without the black lid and clear vent top 

in place when running the 

NutriBullet Rx

•  

TO TURN THE NUTRIBULLET ON IN SOUPERBLAST

 mode using SMART

 

Technology, 

plug the power base into an electrical outlet. Press the power button, located 90˚ to 
the left side of the G-button. The power button will glow 

BLUE

, signifying the power 

is on. Next, place the cup blade-side-down onto the power base. This will activate the 

NutriBullet Rx’s

 SMART TECHNOLOGY function, causing the G-Button at the front of 

the unit to glow 

GREEN

.

•   Press  the 

GREEN

 G-Button down for 2 seconds until it glows 

RED

. This will indicate 

that 

SouperBlast

 mode has begun. The unit will run in 

SouperBlast

 mode for about 7 

minutes before automatically turning off. Once off, simply lift the 

SouperBlast Pitcher

 

off of the Power Base.  

•  The motor will run 3 cycles during the 7 minute program—it will slow down twice 

through the cycle to allow the ingredients to settle for improved processing then 
it will increase again for the next part of the cycle. This is a normal function of the 

NutriBullet Rx

.

•  The contents inside can reach up to about 70ºC / 150ºF through the friction of the rotating blade.
•  If you wish to process your soup for less than the programmed time, you may simply 

lift off the 

SouperBlast Pitcher 

or press the power button, located 90˚ to the left side of 

the G-button.

•  Always allow it to come to a complete stop prior to adding additional ingredients 

during the processing period. 

•  Always depress the power button when not in use. The 

BLUE

 light will stop glowing, 

signifying the power is off.

Содержание Rx

Страница 1: ...U S E R G U I D E N A T U R E S P R E S C R I P T I O N ...

Страница 2: ...not allow cord to touch hot surfaces including stove Periodically inspect cord and plug for damage Do not operate any appliance with a damaged cord or plug If the appliance malfunctions or is dropped or damaged in any manner discontinue use Contact Customer Service for assistance in obtaining a replacement Do not remove the rubber liner inside the power base To clean unplug first then wipe with a ...

Страница 3: ...F OR LESS SOUP WILL HEAT DURING THE EXTRACTION PROCESS TO 65ºC 150ºF DO NOT RUN THE NUTRIBULLET Rx WITH EMPTY NUTRIBULLET Rx CUPS OR SOUPBLAST PITCHER AS THIS CAN DAMAGE THE UNIT AFTER BLENDING INGREDIENTS REMOVE THE BLADE ASSEMBLY ALLOW THE VESSEL WITH IT S CONTENTS TO SETTLE AND TO RELEASE ANY PRESSURE THAT MAY HAVE BUILT UP DURING THE EXTRACTION PROCESS IF YOU WILL NOT CONSUME IT IMMEDIATELY US...

Страница 4: ...OR 10 MIN AFTER 4 5 CYCLES TO PREVENT OVERHEATING AND DAMAGING THE UNIT To prevent leakage always align and hand tighten or use blade remover to tighten the blade to the NutriBlast Rx cup prior to inverting it and placing the assembly on to the motor base TO TURN ON THE NUTRIBULLET Plug the power base into an electrical outlet Press the power button located 90 to the left side of the G button This...

Страница 5: ...NTS WILL BECOME HOT AND MAY SPLASH OUT AND CAUSE INJURY DO NOT TOUCH SOUPERBLAST PITCHER DIRECTLY WITH HANDS AFTER SOUPERBLAST MODE THE SOUPERBLAST PITCHER SURFACE BLADES AND COUPLING GEAR WILL BE HOT ALWAYS USE APPROPRIATE HEAT RESISTANT PADS ON THE HANDLE TO HOLD THE SOUPERBLAST PITCHER AND TO SUPPORT THE BOTTOM OF THE CONTAINER CAREFULLY OPEN SOUPERBLAST PITCHER LID AFTER SOUPERBLAST MODE AS ES...

Страница 6: ... Rx Cups or SouperBlast Pitcher make your cleanup a snap by filling the cup about 2 3 full with warm soapy water and screw on the Extractor Blade and if using the SouperBlast Pitcher put on lids Place the cup assembly on the NutriBullet Rx Power Base for about 20 30 seconds That will loosen the stuck ingredients and with a light scrub and rinse you ll be all done CLEANING THE NUTRIBULLET Rx POWER ...

Страница 7: ...r Lid 1 Short Cup with 1 Comfort Lip Ring 1 SouperBlast Pitcher with 2 piece Lid 1 High torque Power Base 1 User Guide 1 Recipe Book 1 Blade Cleaning Brush 1 Blade Remover WHAT YOU GET 1 Extractor Blade 1 High torque Power Base 1 Stay fresh Resealable Lid ...

Страница 8: ...E SOUPERBLAST MODE WHEN EXTRACTING OIL BASED OR STICKY FOODS REFER TO INSTRUCTIONS LISTED UNDER TAP TECHNIQUE ON PAGE 19 DO NOT TOUCH COUPLING GEAR DIRECTLY WITH HANDS AFTER NUTRIBLAST MODE THE COUPLING GEAR IN BLADE BASE AND POWER BASE WILL BE HOT TO TURN OFF THE MACHINE AT ANYTIME DURING THE NUTRIBLAST CYCLE G BUTTON WILL BE GREEN PRESS THE POWER BUTTON LOCATED 90 TO THE LEFT SIDE OF THE G BUTTO...

Страница 9: ... SouperBlast Mode for the same hot soup If more heat is required place the contents in a microwave safe container and continue heating to desired temperature To make a new soup empty old contents add new ingredients and wait 1 full minute before returning the vessel to the Power Base to start a new SMART Technology cycle Do not repeat more than 2 cycles in SouperBlast mode resting 1 minute between...

Страница 10: ...ead of being recirculated into the cutting zone simply use the Tap technique TakethecupandbladeassemblyoffthePowerBase and Tap the cup and blade assembly on the counter to force the ingredients down into the blades Place the cup and blade assembly onto the Power Base and finish processing 1 1 2 2 WHEN MAKING NUT BUTTERS OR OIL BASED FOODS DUE TO THE CONSISTENCY THE FOOD WILL PROCESS AND THEN STICK...

Страница 11: ...ss the activator buttons down while the Power Base is plugged in CLEANING SAFEGUARDS AFTER MAKING A NUTRIBLAST OR SOUPERBLAST THE BLADE MUST BE CLEANED IMMEDIATELY ALWAYS UNPLUG POWER BASE AND DEPRESS THE THE POWER BUTTON PRIOR TO CLEANING ASSEMBLING OR DISASSBMBLING NEVER SUBMERGE THE POWER BASE IN WATER OR PLACE IT IN THE DISHWASHER WIPE OFF ANY DEBRIS INSIDE THE POWER BASE IMMEDIATELY TO KEEP I...

Страница 12: ... part of your NUTRIBLAST Rx adding additional fiber and nutrition to every sip Add 1 8 to cup to any Blast MAX 22 50 leafy greens 2 cups 1 serving 50 fruit as many varieties as possible Add boost Add water to MAX line WARNING BAD SEEDS While NUTRITION EXTRACTION can be amazingly beneficial not all fruit seeds and rinds are created equal The following seeds and pits contain a chemical that releases...

Страница 13: ..._____ ________________________________________________ ________________________________________________ NOTES ________________________________________________ ________________________________________________ ________________________________________________ ________________________________________________ ________________________________________________ _____________________________________________...

Страница 14: ...________ ________________________________________________ ________________________________________________ ________________________________________________ ________________________________________________ ________________________________________________ ________________________________________________ ________________________________________________ ________________________________________________...

Страница 15: ...e in the world The power speed heating capabilities and unique design of the NUTRIBULLET Rx make it easier than ever to maximize your daily intake and absorption of vegetables fruits nuts seeds and other superfoods the very foods that have been scientifically proven to reduce mortality when consumed and absorbed in abundance Join the millions of NutriBullet users who have transformed their health ...

Отзывы: