background image

Page 3

MODEL  QTXN110SL   

1b.Mount housing anywhere between 

trusses, joists, or 

I

-joists using hanger 

bars.

Sliding hanger bars are provided to allow for accurate posi-

tioning of housing anywhere between framing. They can be

XVHGRQDOOW\SHVRIIUDPLQJ

I

-joist, standard joist, and truss

FRQVWUXFWLRQDQGVSDQXSWR´

$WWDFKWKH02817,1*&+$11(/6WRWKHKRXVLQJXVLQJWKH

SCREWS

VXSSOLHG0DNHVXUH7$%6IDFH³XS´DVVKRZQ

8VHWKHVHWRIFKDQQHOPRXQWLQJKROHVPDUNHG³67'´WR
PRXQWWKHKRXVLQJÀXVKZLWKWKHERWWRPRIWKHGU\ZDOO8VH
WKH RWKHU VHW RI KROHV QRW PDUNHG WR PRXQW WKH KRXVLQJ
ÀXVKZLWKWKHWRSRIWKHGU\ZDOO

HANGER

%$5

6&5(:6

Extend HANGER BARS to the width of the framing.

 Hold ventilator in place with the hanger bar tabs wrapping

around the

%27720('*(2)7+()5$0,1*

.

1$,/YHQWLODWRUWRIUDPLQJRUIDVWHQZLWKVFUHZVQRWSURYLGHG

through

+2/(6

near nails.

*

To ensure a noise-free mount: Secure hanger bars together

with SCREWS or use a pliers to crimp mounting channels

tightly around hanger bars.

*

6&5(:

+2/()25237,21$/

6&5(:02817,1*

02817,1*

&+$11(/

1$,/

%27720('*(

2))5$0,1*

4. Connect electrical wiring.

5XQ9$&KRXVHZLULQJWRLQVWDOODWLRQORFDWLRQ8VH
SURSHU8/DSSURYHGFRQQHFWRUWRVHFXUHKRXVHZLULQJWR

wiring plate. Connect wires as shown in wiring diagrams.

CONNECT WIRING

MODEL 66V/66W, P66V/P66W

3-FUNCTION CONTROL (PURCHASE SEPARATELY)

LIGHT

(ON/OFF)

COM

NIGHT LIGHT

(ON/OFF)

FAN

(AUTO/OFF)

120

VAC

LINE

IN

SWITCH BOX

WHT

GRD

BLK

BLU

RED

WHT

UNIT

ORG

BLK

WHT
GRD

BLK

RED

LIGHT

NIGHT LIGHT

WHT

WHT

BLK

WHT

BRN

HUMIDITY

CONTROL

FAN

2. Attach damper/

duct connector.

Snap damper / duct con-

QHFWRURQWRKRXVLQJ0DNH
VXUHFRQQHFWRULVÀXVK

with top of housing and

GDPSHUÀDSIDOOVFORVHG

3. Install

6-inch round duc-

twork.

Connect 6-inch round

ductwork to damper / duct

connector. Run ductwork

to a roof cap or wall cap.

Tape all ductwork con-

nections to make them

secure and air tight.

MODEL 77DV, 77DW, P77DV, P77DW

4-FUNCTION CONTROL (PURCHASE SEPARATELY)

FAN

(ON/OFF/AUTO)

120

VAC

LINE

IN

SWITCH BOX

GRD

RED

RED

BLU

UNIT

RED

BLU

WHT

GRD

WHT

BLK

BLK

RED

WHT

BLK

NIGHT LIGHT

(ON/OFF)

LIGHT

(ON/OFF)

COM

COM

BLK

BLK

WHT

ORG

WHT

BLK

WHT

BRN

HUMIDITY

CONTROL

FAN

WHT

NIGHT LIGHT

LIGHT

WIRING OPTION #1

 - Allows fan to operate in automatic mode or manual mode 

(for odor control) by cycling ON/OFF switch.

WIRING OPTION #2

 - Fan can be turned ON, OFF, or set to operate automatically.

TAB

Отзывы: