MODEL  QTXN110SL   

WARNING  

TO REDUCE THE RISK OF FIRE, ELECTRIC 

SHOCK, OR INJURY TO PERSONS, OB-

SERVE THE FOLLOWING:

1. Use this unit only in the manner intended

by the manufacturer. If you have questions,

contact the manufacturer at the address or

telephone number listed in the warranty.

2. Before servicing or cleaning unit, switch

power off at service panel and lock the ser-

vice disconnecting means to prevent power

from being switched on accidentally. When

the service disconnecting means cannot be

locked, securely fasten a prominent warning

device, such as a tag, to the service panel.

3. Installation work and electrical wiring must be

GRQHE\DTXDOL¿HGSHUVRQVLQDFFRUGDQFH

with all applicable codes and standards,

LQFOXGLQJ¿UHUDWHGFRQVWUXFWLRQFRGHVDQG

standards.

 6XI¿FLHQWDLULVQHHGHGIRUSURSHUFRPEXVWLRQ

DQGH[KDXVWLQJRIJDVHVWKURXJKWKHÀXH
FKLPQH\RIIXHOEXUQLQJHTXLSPHQWWRSUH

-

vent backdrafting. Follow the heating equip-

ment manufacturer’s guideline and safety

standards such as those published by the

1DWLRQDO)LUH3URWHFWLRQ$VVRFLDWLRQ1)3$

and the American Society for Heating, Re-

frigeration and Air Conditioning Engineers

$6+5$(DQGWKHORFDOFRGHDXWKRULWLHV

5. When cutting or drilling into wall or ceiling, do

notdamageelectricalwiringandotherhidden

utilities.

6. Ducted fans must always be vented to the

outdoors.

7. Acceptableforuseoveratuborshowerwhen

FRQQHFWHGWRD*)&,*URXQG)DXOW&LUFXLW
,QWHUUXSWHUSURWHFWHGEUDQFKFLUFXLW

8. This unit must be grounded.

CAUTION

1. For general ventilating use only. Do not use

to exhaust hazardous or explosive materials

and vapors.

2. This product is designed for installation in

ÀDWFHLOLQJVRQO\'212,6
352'8&7,1$:$//

3. To avoid motor bearing damage and noisy

and/or unbalanced impellers, keep drywall

spray, construction dust, etc. off power unit.

 3OHDVHUHDGVSHFL¿FDWLRQODEHORQSURGXFWIRU

further information and requirements.

HUMIDITY SENSING

FAN / LIGHT / NIGHT LIGHT

READ AND SAVE THESE INSTRUCTIONS

CLEANING & 
MAINTENANCE

Installer: Leave this manual 

with the homeowner.

)RUTXLHWDQGHI¿FLHQWRSHUDWLRQORQJOLIH

and attractive appearance - lower or remove

grille and vacuum interior of unit with the

dusting brush attachment.
The motor is permanently lubricated and

never needs oiling. If the motor bearings are

making excessive or unusual noises, replace

the motor with the exact service motor. The

impeller should also be replaced.

SENSOR CLEANING

The humidity sensor is mounted in the grille.

The sensor will operate most reliably when

cleaned occasionally as follows:

1. Disconnect power at service entrance.
2. Remove the grille. Use a dry dustcloth,

clean toothbrush, or lightly vacuum to

FOHDQVHQVRUDQGJULOOH'212786(
$%5$6,9( &/27+ 67((/ :22/
3$'6256&285,1*32:'(56

'212786(FOHDQLQJVSUD\VVROYHQWV

or water on or near the sensor!

OPERATION

The humidity control and fan can be 

oper-ated separately. Use a 1- or 2-func-

tion wall control. Do not use a dimmer 

switch to operate the humidity control or 

light. See “Connect Wiring” for details.
SENSOR OPERATION

This humidity-sensing fan responds to:     

D UDSLG WR PRGHUDWH KXPLGLW\ LQFUHDVHV
DQGEKXPLGLW\DERYHDUHOD

-

WLYHKXPLGLW\VHWSRLQWDDQGEDUHVHW

with “SENSITIVITY” adjustment. Fan may

occasionally turn on when environ-mental

conditions change. If the fan contin-uously

responds to changing environ-mental condi-

tions, “SENSITIVITY” adjust-ment may be

UHTXLUHGVHHVHFWLRQEHORZ

STATUS INDICATOR

This indicator can only be seen by looking

directly at it. Normal mode is 5-seconds  on

and off.  If it blinks rapidly for 5-seconds and

then off, check sensor connections on grille

and fan housing.

MANUAL ON WITH TIMED OFF

For odor or vapor control, the fan can be en-

ergized by cycling its wall-mounted switch

LIRQHLVLQVWDOOHG2QFHWKHIDQKDVEHHQ

turned on in this manner, it will remain on

IRUWKHVHW³7,0(5´SHULRG

To manually energize the fan:

1. Go to Step 2 if switch is already on;

otherwise, turn switch on for more than

1 second.

2. Switch off for less than 1 second.
3. Switch back on and fan will turn on.

SENSITIVITY ADJUSTMENT

“SENSITIVITY” has been factory set for

most shower applications. If the fan is in a

tub area or is used for dampness control,

the “SENSITIVITY” may need to be in-

FUHDVHGWRZDUGPD[LPXP³0$;´,IWKH

control is responding too often to changing

environmental conditions, adjustment to-

ZDUGOHVV³0,1´³6(16,7,9,7<´PD\EH

required. To adjust the “SENSITIVITY”:

1. Turn power off at electrical service

panel.

2.  T h r o u g h t h e g r i l l e , l o c a t e t h e

“SENSITIVITY” screwdriver slot.

8VLQJ D VPDOO ÀDWEODGH VFUHZGULYHU

carefully rotate “SENSITIVITY” adjust-

PHQWWRZDUG³0$;´RU³0,1´

4. Turn power on and check operation

by turning on shower or other humidity

source until fan turns on.

5. Repeat above steps if necessary.

TIMER  ADJUSTMENT

7KLVKXPLGLW\VHQVLQJIDQKDVD³7,0(5´,W
LVXVHUDGMXVWDEOHIURPWRPLQXWHVDQG
LVIDFWRU\VHWDWPLQXWHV7KH³7,0(5´
FRQWUROV KRZ ORQJ WKH IDQ UHPDLQV RQ D
DIWHUULVHLQKXPLGLW\DQGEKXPLGLW\OHYHO

are both below the user-adjustable “SEN-

SITIVITY” setting or after being energized

by cycling power switch.

7RDGMXVWWKH³7,0(5´

1. Disconnect power at electrical service

panel.

7KURXJKWKHJULOOHORFDWHWKH³7,0(5´

screwdriver slot.

8VLQJ D VPDOO ÀDWEODGH VFUHZGULYHU

FDUHIXOO\URWDWH³7,0(5´DGMXVWPHQWWR
GHVLUHGVHWWLQJWRPLQXWHV

4. Check operation by cycling power

VZLWFK DV LQVWUXFWHG XQGHU ³0$18$/
21:,7+7,0('2))´RUE\WXUQLQJRQ

a humidity source until fan turns on.

&KHFN ³7,0(5´ VHWWLQJ ZLWK ZDWFK RU

clock after turning humidity source off

if it was turned on it Step 4.

6. Repeat above steps if necessary.