Page 1
MODEL QTXN110SL
WARNING
TO REDUCE THE RISK OF FIRE, ELECTRIC
SHOCK, OR INJURY TO PERSONS, OB-
SERVE THE FOLLOWING:
1. Use this unit only in the manner intended
by the manufacturer. If you have questions,
contact the manufacturer at the address or
telephone number listed in the warranty.
2. Before servicing or cleaning unit, switch
power off at service panel and lock the ser-
vice disconnecting means to prevent power
from being switched on accidentally. When
the service disconnecting means cannot be
locked, securely fasten a prominent warning
device, such as a tag, to the service panel.
3. Installation work and electrical wiring must be
GRQHE\DTXDOL¿HGSHUVRQVLQDFFRUGDQFH
with all applicable codes and standards,
LQFOXGLQJ¿UHUDWHGFRQVWUXFWLRQFRGHVDQG
standards.
6XI¿FLHQWDLULVQHHGHGIRUSURSHUFRPEXVWLRQ
DQGH[KDXVWLQJRIJDVHVWKURXJKWKHÀXH
FKLPQH\RIIXHOEXUQLQJHTXLSPHQWWRSUH
-
vent backdrafting. Follow the heating equip-
ment manufacturer’s guideline and safety
standards such as those published by the
1DWLRQDO)LUH3URWHFWLRQ$VVRFLDWLRQ1)3$
and the American Society for Heating, Re-
frigeration and Air Conditioning Engineers
$6+5$(DQGWKHORFDOFRGHDXWKRULWLHV
5. When cutting or drilling into wall or ceiling, do
notdamageelectricalwiringandotherhidden
utilities.
6. Ducted fans must always be vented to the
outdoors.
7. Acceptableforuseoveratuborshowerwhen
FRQQHFWHGWRD*)&,*URXQG)DXOW&LUFXLW
,QWHUUXSWHUSURWHFWHGEUDQFKFLUFXLW
8. This unit must be grounded.
CAUTION
1. For general ventilating use only. Do not use
to exhaust hazardous or explosive materials
and vapors.
2. This product is designed for installation in
ÀDWFHLOLQJVRQO\'212,6
352'8&7,1$:$//
3. To avoid motor bearing damage and noisy
and/or unbalanced impellers, keep drywall
spray, construction dust, etc. off power unit.
3OHDVHUHDGVSHFL¿FDWLRQODEHORQSURGXFWIRU
further information and requirements.
HUMIDITY SENSING
FAN / LIGHT / NIGHT LIGHT
READ AND SAVE THESE INSTRUCTIONS
CLEANING &
MAINTENANCE
Installer: Leave this manual
with the homeowner.
)RUTXLHWDQGHI¿FLHQWRSHUDWLRQORQJOLIH
and attractive appearance - lower or remove
grille and vacuum interior of unit with the
dusting brush attachment.
The motor is permanently lubricated and
never needs oiling. If the motor bearings are
making excessive or unusual noises, replace
the motor with the exact service motor. The
impeller should also be replaced.
SENSOR CLEANING
The humidity sensor is mounted in the grille.
The sensor will operate most reliably when
cleaned occasionally as follows:
1. Disconnect power at service entrance.
2. Remove the grille. Use a dry dustcloth,
clean toothbrush, or lightly vacuum to
FOHDQVHQVRUDQGJULOOH'212786(
$%5$6,9( &/27+ 67((/ :22/
3$'6256&285,1*32:'(56
'212786(FOHDQLQJVSUD\VVROYHQWV
or water on or near the sensor!
OPERATION
The humidity control and fan can be
oper-ated separately. Use a 1- or 2-func-
tion wall control. Do not use a dimmer
switch to operate the humidity control or
light. See “Connect Wiring” for details.
SENSOR OPERATION
This humidity-sensing fan responds to:
D UDSLG WR PRGHUDWH KXPLGLW\ LQFUHDVHV
DQGEKXPLGLW\DERYHDUHOD
-
WLYHKXPLGLW\VHWSRLQWDDQGEDUHVHW
with “SENSITIVITY” adjustment. Fan may
occasionally turn on when environ-mental
conditions change. If the fan contin-uously
responds to changing environ-mental condi-
tions, “SENSITIVITY” adjust-ment may be
UHTXLUHGVHHVHFWLRQEHORZ
STATUS INDICATOR
This indicator can only be seen by looking
directly at it. Normal mode is 5-seconds on
and off. If it blinks rapidly for 5-seconds and
then off, check sensor connections on grille
and fan housing.
MANUAL ON WITH TIMED OFF
For odor or vapor control, the fan can be en-
ergized by cycling its wall-mounted switch
LIRQHLVLQVWDOOHG2QFHWKHIDQKDVEHHQ
turned on in this manner, it will remain on
IRUWKHVHW³7,0(5´SHULRG
To manually energize the fan:
1. Go to Step 2 if switch is already on;
otherwise, turn switch on for more than
1 second.
2. Switch off for less than 1 second.
3. Switch back on and fan will turn on.
SENSITIVITY ADJUSTMENT
“SENSITIVITY” has been factory set for
most shower applications. If the fan is in a
tub area or is used for dampness control,
the “SENSITIVITY” may need to be in-
FUHDVHGWRZDUGPD[LPXP³0$;´,IWKH
control is responding too often to changing
environmental conditions, adjustment to-
ZDUGOHVV³0,1´³6(16,7,9,7<´PD\EH
required. To adjust the “SENSITIVITY”:
1. Turn power off at electrical service
panel.
2. T h r o u g h t h e g r i l l e , l o c a t e t h e
“SENSITIVITY” screwdriver slot.
8VLQJ D VPDOO ÀDWEODGH VFUHZGULYHU
carefully rotate “SENSITIVITY” adjust-
PHQWWRZDUG³0$;´RU³0,1´
4. Turn power on and check operation
by turning on shower or other humidity
source until fan turns on.
5. Repeat above steps if necessary.
TIMER ADJUSTMENT
7KLVKXPLGLW\VHQVLQJIDQKDVD³7,0(5´,W
LVXVHUDGMXVWDEOHIURPWRPLQXWHVDQG
LVIDFWRU\VHWDWPLQXWHV7KH³7,0(5´
FRQWUROV KRZ ORQJ WKH IDQ UHPDLQV RQ D
DIWHUULVHLQKXPLGLW\DQGEKXPLGLW\OHYHO
are both below the user-adjustable “SEN-
SITIVITY” setting or after being energized
by cycling power switch.
7RDGMXVWWKH³7,0(5´
1. Disconnect power at electrical service
panel.
7KURXJKWKHJULOOHORFDWHWKH³7,0(5´
screwdriver slot.
8VLQJ D VPDOO ÀDWEODGH VFUHZGULYHU
FDUHIXOO\URWDWH³7,0(5´DGMXVWPHQWWR
GHVLUHGVHWWLQJWRPLQXWHV
4. Check operation by cycling power
VZLWFK DV LQVWUXFWHG XQGHU ³0$18$/
21:,7+7,0('2))´RUE\WXUQLQJRQ
a humidity source until fan turns on.
&KHFN ³7,0(5´ VHWWLQJ ZLWK ZDWFK RU
clock after turning humidity source off
if it was turned on it Step 4.
6. Repeat above steps if necessary.