MODEL  QTNLEDB

4. Connect electrical wiring.

Run 120 VAC house wiring to installation location. Use
proper UL approved connector to secure house wiring to
wiring plate. Connect wires as shown in wiring diagrams.

CONNECT WIRING

2. Attach

damper/duct

connector.

Snap damper /

duct connector

onto housing. 

Make sure

connector is flush

with top of housing

and damper flap

falls closed.

3. Install

6-inch or

4-inch round

ductwork.

Connect 6-inch 

or 4-inch round 

ductwork to 

damper / duct 

connector or 

reducer. Run 

ductwork to a roof 

cap or wall cap. 

Tape all ductwork 

connections to make them secure and air tight.

1b. Mount housing anywhere between 

trusses, joists, or 

I

-joists using hanger 

bars.

Sliding hanger bars are provided to allow for accurate 

positioning of housing anywhere between framing. They can 

be used on all types of framing (

I

-joist, standard joist, and 

truss construction) and span up to 24”.

Attach the MOUNTING CHANNELS to the housing using 

the SCREWS supplied. Make sure TABS face “up” as shown. 

Use the set of channel mounting holes (marked “STD”) to 

mount the housing flush with the bottom of the drywall. Use 

the other set of holes (not marked) to mount the housing 

flush with the top of the drywall.

HANGER

BAR (4)

SCREWS (4)

TAB

Extend HANGER BARS to the width of the framing.
Hold ventilator in place with the hanger bar tabs wrapping 

around the BOTTOM EDGE OF THE FRAMING.
NAIL ventilator to framing or fasten with screws (not provided) 

through HOLES near nails.

*

 To ensure a noise-free mount: Secure hanger bars together

with  SCREWS or use a pliers to crimp mounting channels

tightly around hanger bars.

HOLE FOR OPTIONAL 

SCREW MOUNTING (4)

STD

MOUNTING

CHANNEL (2)

NAIL (4)

BOTTOM EDGE 

OF FRAMING

*

SCREW (2)