FIGURE 15

FIGURE 16

MODEL 365

DOUBLE FLANGED

TEE

WALL
INLET

MOUNTING

BRACKET

SHORTEN

WALL

FIGURE 13

FIGURE 14

WALL INLET INSTALLATION

MODEL 360 WALL INLET(361 Rough in)

1. Once the walls have been finished, install the wall inlets.
2. Remove the cardboard plaster guard.
3. 

Refer to Figure 13. 

For some dry wall or panel construction,

the plaster frame will extend beyond the finished wall. In this
case, remove plaster frame from mounting bracket by
removing mounting screws.

4. 

Refer to Figure 14. 

Connect 2-conductor low voltage wire to

terminal screws on back of wall inlet.

5. Guide excess wire back through hole in inlet bracket and

make sure seal is secure between mounting bracket and
flanged fitting.

6. 

Refer to Figure 15. 

Place inlet into mounting bracket and

secure.

NOTE: When wall inlets are installed in 1/2" thick walls or
less, the tube of the wall inlet may extend into elbow area of
the flanged fitting and cause blockage. Shorten the wall
inlet tube to prevent this condition. See Figure 16.

For extra thick walls, use Model 399 extension sleeves to

connect inlet to the flanged fitting.

MODEL 330 WALL INLET (329 Rough in)

See Figure 17.
1. Connect 2-conductor low voltage wire to terminal screws on

back of wall inlet.

2. Align inlet mounting holes with holes in mounting plate.
3. Place inlet into mounting plate and secure with two provided

screws.

MOUNTING

PLATE

INLET

FIGURE 17

Содержание CV-352

Страница 1: ...In 4 Installing the Tubing 4 Installation Hints 4 Tubing Installation 5 Wall Inlet Installation 6 Model 360 Wall Inlet 6 Model 330 Wall Inlet 6 Power Unit Installation 7 Dimensional Chart 7 Mounting 7...

Страница 2: ...in the basement conveniently located for shop use and messy cleaning jobs The intake tubing runs up the basement wall and connects to the main trunk line which runs along the unfinished basement ceil...

Страница 3: ...unit should be exhausted to the outside The exhaust should not be vented into a wall a ceiling or a concealed space in the house The exhaust line should be terminated outside the home using Model 393...

Страница 4: ...nlet bracket See Figure 5A Spacer may be made from plywood masonite etc Contact cement may be used to hold spacer in place during assembly MODEL 329 SIDE MOUNTING FACE MOUNTING MODEL 361 23 8 113 16 F...

Страница 5: ...eck for proper length 6 Refer to Figure 10 Apply cement Model 379 to outside of tubing Coat tubing approximately 1 back Take care to keep cement from inside of tube 7 Refer to Figure 11 Insert tubing...

Страница 6: ...e back through hole in inlet bracket and make sure seal is secure between mounting bracket and flanged fitting 6 Refer to Figure 15 Place inlet into mounting bracket and secure NOTE When wall inlets a...

Страница 7: ...ctric shock This appliance is equipped with a cord having an equipment grounding conductor and grounding plug The plug must be plugged into an appropriate outlet that is properly installed and grounde...

Страница 8: ...ften find a hollow space behind these appliances If this space lines up with an obstruction free interior wall above or a closet this might be a key to your installation In a ranch style home this key...

Страница 9: ...e from mounting bracket Pull low voltage wire through hole in bracket and insert bracket into cutout Secure bracket to flanged fitting with four screws provided Be sure seal is secure between flange f...

Страница 10: ...of inlet must be located at least 21 2 from wall to allow cover to be opened when hose is inserted 2 Determine direction of tubing and attach appropriate flanged fitting to mounting bracket with four...

Страница 11: ...anual on off operation Check each wall inlet to be sure contacts activate power unit when hose is inserted A short piece of wire can be used to short contacts in wall inlet together to activate power...