background image

MODELS  CFO52BQ • CFO52WB • CFO52WH

Page 6

ATTACH FAN BLADES

Caution:  Remove  5  rubber  packing  mounts  and  discard  before 

installation.

Your  fan  is  equipped  with  2-sided  reversible  blades  (except  Model 

CFO52BQ). Select the finish and install the blade brackets over the 

side of the blades that will be visible.

1.  Attach the blade to the blade bracket using the screws and fiber 

washers as shown in Figure 12. Start screw into bracket. Repeat 

for the two remaining screws.

2.  Tighten each screw. Make sure the blade is straight.

3.  Fasten blade assembly to motor using the screws supplied. (Fig. 

12)

4.  Attach decorative fob to pull chain.

OPERATION

Turn on the power and check the operation of your fan.

3-SPEED PULL CHAIN

Controls the fan speed as follows: 1 pull - High, 2 pulls - Medium, 3 

pulls - Low, and 4 pulls - Off.
Speed settings for warm or cool weather depend on factors such as the 

room size, ceiling height, and number of fans.

SLIDE SWITCH

Controls directions: forward (switch down) or reverse (switch up).

NOTE:  Wait  for  fan  to  stop  before  changing  the  setting  of  the 

slide switch.

Warm weather - (Forward) A downward airflow creates a cooling effect 

as shown in Fig. 13. This allows you to set your air conditioner on a 

warmer setting without affecting your comfort.
Cool weather - (Reverse) An upward airflow moves warm air off the 

ceiling area as shown in Fig. 14. This allows you to set your heating 

unit on a cooler setting without affecting your comfort.

WALL SWITCH (OPTIONAL)

Your fan is also designed to operate with a wall switch (sold separately). 

Refer to wall switch instructions for installation and wiring information.

SCREWS

FIBER

WASHERS

BLADE

BLADE BRACKET

SCREWS

FIGURE 12

FIGURE 13

FIGURE 14

Содержание CFO52BQ

Страница 1: ...0 After marking electrical connections spliced conductors should be turned upward and pushed carefully up into outlet box The wires should be spread apart with the grounded conductor and the equipment...

Страница 2: ...directly to the building structure Use appropriate fasteners and building materials The outlet box and its support must be able to fully support the moving weight of the fan at least 50 lbs Do not use...

Страница 3: ...canopy and then through the ball downrod and rubber ball cover Fig 6 5 Align the holes at the bottom of the downrod with the holes in the collar on top of the motor housing Carefully insert the hange...

Страница 4: ...the wiring connections for optional wall control The wire color out of wall control may vary see wall control s installation manual for correct wire connections WARNING TO REDUCE THE RISK OF FIRE ELE...

Страница 5: ...TALLATION 1 Slide canopy up to the ceiling as shown in Figure 11 Make sure you place the wires safely into the outlet box 2 Secure the canopy to the hanger bracket with the four screws with your fan F...

Страница 6: ...s 1 pull High 2 pulls Medium 3 pulls Low and 4 pulls Off Speed settings for warm or cool weather depend on factors such as the room size ceiling height and number of fans SLIDE SWITCH Controls directi...

Страница 7: ...lade bracket to the motor hub is tight 3 Make sure wire nut connections are not rubbing against each other or the interior wall of the switch housing CAUTION Make sure main power is off 4 Allow a 24 h...

Страница 8: ...WNROD W BALL 6 CFO52WB S77000894 DOWNROD W BALL 6 CFO52BQ 6 S77000919 REVERSING SWITCH 7 WIRES WHITE S77000920 REVERSING SWITCH 7 WIRES BLACK 7 S77000921 PULL CHAIN SWITCH POLISHED BRASS CHAIN S770009...

Страница 9: ...natural elements g damage in transit h finish on any metal portion of the fan or accessory i Fans in commercial or nonresidential use or j damage caused by fire flood or other act of God This warrant...

Страница 10: ...10 Despu s de realizar las conexiones el ctricas debe girar los conductores empalmados hacia arriba e introducirlos con cuidado en la caja de distribuci n Deber separar los cables con el conductor a t...

Страница 11: ...las abrazaderas y los materiales de armado correspondientes La caja de distribuci n y su soporte deben soportar el peso total del ventilador en movimiento por lo menos 50 libras 22 kg No utilice caja...

Страница 12: ...bierta de pelota de goma Fig 6 5 Alinee los orificios de la parte inferior de la barra descendente con los orificios del aro en la parte superior de la carcasa del motor Con cuidado inserte el pivote...

Страница 13: ...cables para un control de pared opcional el color de los cables fuera del control de pared puede variar lea el manual de instalaci n del control de pared para conocer las conexiones correctas de los c...

Страница 14: ...asa hacia el techo como lo muestra la figura 11 Aseg rese de colocar los cables con seguridad en la caja de distribuci n 2 Sujete la carcasa al soporte de suspensi n con los cuatro tornillos incluidos...

Страница 15: ...aja y 4 tirones apagado La configuraci n de las velocidades para temperaturas c lidas o fr as depende de diversos factores como el tama o de la habitaci n la altura del techo y la cantidad de ventilad...

Страница 16: ...el motor est n bien ajustados 3 Aseg rese de que no haya fricci n entre las conexiones de las tuercas para alambres o con la pared interior de la carcasa de interruptores PRECAUCI N Aseg rese de que e...

Страница 17: ...7000894 BARRA DESCENDENTE CON BOLA DE 6 CFO52BQ 6 S77000919 INVERSOR 7 CABLES BLANCO S77000920 INVERSOR 7 CABLES NEGRO 7 S77000921 INTERRUPTOR DE CADENILLA DE TIRO CADENA DE BRONCE PULIDO S77000922 IN...

Страница 18: ...el ventilador o el accesorio i ventiladores en uso comercial o no residencial o j da os ocasionados por incendio inundaci n u otro caso fortuito Esta garant a cubre nicamente los ventiladores vendidos...