1.  Use this unit only in the manner intended by the manufacturer. If 

you have questions, contact the manufacturer at the address or 

telephone number listed in the warranty.

2.  Before servicing or cleaning unit, or installing a light kit, switch power 

off at service panel and lock service panel to prevent power from 

being switched on accidentally. When the service disconnecting 

means  cannot  be  locked,  securely  fasten  a  prominent  warning 

device, such as a tag, to the service panel.

3.  Installation work and electrical wiring must be done by a qualified 

person(s) in accordance with all applicable codes and standards, 

including fire-rated construction codes and standards.

4.  When cutting or drilling into wall or ceiling, do not damage electrical 

wiring and other hidden utilities.

5.  This unit must be grounded.
6.  Do not use this fan with any solid-state fan speed control device.
7.  Most outlet boxes commonly used for the support of lighting fixtures 

are not acceptable for fan support and may need to be replaced, 

consult a qualified electrician if in doubt.

 

Use only UL Listed outlet boxes marked “FOR FAN SUPPORT”. 

The outlet box and support structure must be securely mounted 

and capable of reliably supporting a minimum of 50 pounds. Use 

only the two steel screws (and lock washers) provided with the 

outlet box for mounting the ceiling fan to the outlet box The outlet 

box must not twist or work loose. DO NOT USE PLASTIC OUTLET 

BOXES.

8.  Use  only  with  light  kit  marked  “SUITABLE  FOR  USE  IN  WET 

LOCATIONS”.

9.  Damp-rated  light  kits  can  be  used  with  this  fan  ONLY  if  fan  is 

mounted in damp or dry location. Consult with a qualified electrician 

if in doubt.

10.  After  marking  electrical  connections,  spliced conductors  should 

be  turned  upward  and  pushed  carefully  up  into  outlet  box.  The 

wires should be spread apart with the grounded conductor and the 

equipment-grounding conductor on one side of the outlet box.

11.  Electrical diagrams are for reference only. Light kits that are not 

packed with the fan must be UL Listed and marked suitable for use 

with the model fan you are installing. Switches must be UL General 

Use Switches. Refer to the instructions packaged with the light kits 

and switches for proper assembly.

12.  After installation is complete, make sure that all connections are 

secure to prevent the fan from falling. Make sure all wire connections 

are secure, and that there are no exposed conductor strands.

13.  Do not use water or detergents when cleaning the fan or fan blades. 

A dry dust cloth or lightly dampened cloth will be suitable for most 

cleaning.

CAUTION  

TO REDUCE THE RISK OF PERSONAL INJURY, OBSERVE THE 

FOLLOWING: 

1.  To  avoid  motor  bearing  damage  and  noisy  and/or  unbalanced 

impellers, keep drywall spray, construction dust, etc. off power unit.

2.  The fan must be mounted with at least 7 feet of clearance between 

fan blades and floor.

3.  Make sure that your installation will not allow the fan to come into 

contact with any adjacent obstacles such as doors, hanging lamps, 

etc.

4.  If you are installing more than one ceiling fan, do not mix the blade 

sets.

5.  Do not bend the blade brackets.
6.  Do not operate reversing switch while fan blades are in motion. 

Fan must be turned off and blades stopped before reversing blade 

direction.

7.  Do not insert objects in between rotating fan blades.
8.  Be careful when working around or cleaning the fan.
9.  Please read specification label on product for further information 

and requirements.

WEIGHT OF FAN

The weight of your fan is 17.8 lbs. The weights of light kits, down rods, 

and ceiling adapters are listed in the instructions packed with those 

accessories.

INSTALLER: 

Leave this manual with the 

homeowner. 
HOMEOWNER: 

Use and care instructions on 

pages 7 & 8.

Содержание CFO52BQ

Страница 1: ...0 After marking electrical connections spliced conductors should be turned upward and pushed carefully up into outlet box The wires should be spread apart with the grounded conductor and the equipment...

Страница 2: ...directly to the building structure Use appropriate fasteners and building materials The outlet box and its support must be able to fully support the moving weight of the fan at least 50 lbs Do not use...

Страница 3: ...canopy and then through the ball downrod and rubber ball cover Fig 6 5 Align the holes at the bottom of the downrod with the holes in the collar on top of the motor housing Carefully insert the hange...

Страница 4: ...the wiring connections for optional wall control The wire color out of wall control may vary see wall control s installation manual for correct wire connections WARNING TO REDUCE THE RISK OF FIRE ELE...

Страница 5: ...TALLATION 1 Slide canopy up to the ceiling as shown in Figure 11 Make sure you place the wires safely into the outlet box 2 Secure the canopy to the hanger bracket with the four screws with your fan F...

Страница 6: ...s 1 pull High 2 pulls Medium 3 pulls Low and 4 pulls Off Speed settings for warm or cool weather depend on factors such as the room size ceiling height and number of fans SLIDE SWITCH Controls directi...

Страница 7: ...lade bracket to the motor hub is tight 3 Make sure wire nut connections are not rubbing against each other or the interior wall of the switch housing CAUTION Make sure main power is off 4 Allow a 24 h...

Страница 8: ...WNROD W BALL 6 CFO52WB S77000894 DOWNROD W BALL 6 CFO52BQ 6 S77000919 REVERSING SWITCH 7 WIRES WHITE S77000920 REVERSING SWITCH 7 WIRES BLACK 7 S77000921 PULL CHAIN SWITCH POLISHED BRASS CHAIN S770009...

Страница 9: ...natural elements g damage in transit h finish on any metal portion of the fan or accessory i Fans in commercial or nonresidential use or j damage caused by fire flood or other act of God This warrant...

Страница 10: ...10 Despu s de realizar las conexiones el ctricas debe girar los conductores empalmados hacia arriba e introducirlos con cuidado en la caja de distribuci n Deber separar los cables con el conductor a t...

Страница 11: ...las abrazaderas y los materiales de armado correspondientes La caja de distribuci n y su soporte deben soportar el peso total del ventilador en movimiento por lo menos 50 libras 22 kg No utilice caja...

Страница 12: ...bierta de pelota de goma Fig 6 5 Alinee los orificios de la parte inferior de la barra descendente con los orificios del aro en la parte superior de la carcasa del motor Con cuidado inserte el pivote...

Страница 13: ...cables para un control de pared opcional el color de los cables fuera del control de pared puede variar lea el manual de instalaci n del control de pared para conocer las conexiones correctas de los c...

Страница 14: ...asa hacia el techo como lo muestra la figura 11 Aseg rese de colocar los cables con seguridad en la caja de distribuci n 2 Sujete la carcasa al soporte de suspensi n con los cuatro tornillos incluidos...

Страница 15: ...aja y 4 tirones apagado La configuraci n de las velocidades para temperaturas c lidas o fr as depende de diversos factores como el tama o de la habitaci n la altura del techo y la cantidad de ventilad...

Страница 16: ...el motor est n bien ajustados 3 Aseg rese de que no haya fricci n entre las conexiones de las tuercas para alambres o con la pared interior de la carcasa de interruptores PRECAUCI N Aseg rese de que e...

Страница 17: ...7000894 BARRA DESCENDENTE CON BOLA DE 6 CFO52BQ 6 S77000919 INVERSOR 7 CABLES BLANCO S77000920 INVERSOR 7 CABLES NEGRO 7 S77000921 INTERRUPTOR DE CADENILLA DE TIRO CADENA DE BRONCE PULIDO S77000922 IN...

Страница 18: ...el ventilador o el accesorio i ventiladores en uso comercial o no residencial o j da os ocasionados por incendio inundaci n u otro caso fortuito Esta garant a cubre nicamente los ventiladores vendidos...

Страница 19: ......

Страница 20: ...79040060A...

Отзывы: