ALLURE

®

 WS3 SERIES

RANGE HOOD  

INSTALL HOOD

KEYHOLE (4)

MOUNTING SCREW (4)

Hang hood from (4) 

Mounting Screws

. Slide hood towards 

wall until mounting screws are engaged in narrow end of 
(4) 

 Keyholes

. Tighten mounting screws securely. A long 

screwdriver works best.

Replace filters, turn on power at service panel, and test for 
proper operation.

Connect ductwork to hood. Use 

Duct Tape

 to make joints 

secure and air tight.

DUCT

TAPE

Replace bottom cover.

PAR20,

50W MAX.

HALOGEN

BULB (2)

- or -
R16,

40W MAX.

INCANDESCENT 

BULB (2)

Install (2) PAR20, 50 W Maximum 

Halogen Bulbs 

or (2) 

R16, 40 W Maximum 

Incandescent Bulbs

. Purchase bulbs 

separately.

!

CAUTION: 

Bulbs may be hot! Refer to bulb packaging 

for further information.

CONNECT WIRING

WARNING: To reduce the risk of electric shock, 
make sure power is switched off at the service 
panel. Lock or tag service panel to prevent power 
from being switched on accidentally.

HOUSE

WIRING

(120 VAC)

CARDBOARD

(Use to protect 

cooktop)

1 Connect 

House Wiring

 (120 VAC) to hood. Use a piece of 

Cardboard

 to protect the cooktop, if necessary.

Connect house black to hood black wire, house white to hood 
white wire, and house ground under 

Green Ground Screw

Securely tighten cable clamp onto house wiring.

GREEN 

GROUND 

SCREW

Содержание ALLURE WS3 Series

Страница 1: ...e cookware appropriate for the size of the surface element TO REDUCE THE RISK OF INJURY TO PERSONS IN THE EVENT OF A RANGE TOP GREASE FIRE OBSERVE THE FOLLOWING 1 SMOTHER FLAMES with a close fitting l...

Страница 2: ...ork between the hood location and a roof cap or wall cap For best results use a minimum number of transitons and elbows 2 Use diagrams below for proper placement of ductwork and electrical cutout in c...

Страница 3: ...SCREWS LIGHT PANEL 2 8 SCREWS 6 Remove Air Chute held in place with one 1 screw NOTE Be care ful not to discon nect any wires AIR CHUTE 8 Rotate baffle Reinsert baffle into air chute as shown so that...

Страница 4: ...Discharge TOP RECTANGULAR DUCT KNOCKOUT Remove for 3 x 10 Vertical 12 Horizontal Discharge Only Remove the Plate in front of the horizontal discharge knockout Cut the Ties lift plate out and discard...

Страница 5: ...4 Install 2 PAR20 50 W Maximum Halogen Bulbs or 2 R16 40 W Maximum Incandescent Bulbs Purchase bulbs separately CAUTION Bulbs may be hot Refer to bulb packaging for further information CONNECT WIRING...

Страница 6: ...d au tomatically adjust the fan to the appropriate setting 1 If the fan is on the Heat Sentry system will increase the fan setting when the temperature is elevated If the temperature continues to rise...

Страница 7: ...R111630 Lamp Socket Assembly 23 R7201731 Light Panel 30 in White R7201751 Light Panel 36 in White R7201771 Light Panel 42 in White R7201734 Light Panel 30 in Black R7201754 Light Panel 36 in Black R7...

Страница 8: ...mplied warranty is limited to the one year period as specified for the express warranty Some states do not allow limitation on how long an implied warranty lasts so the above limitation may not apply...

Отзывы: