POWER/BLOWER UNIT INSTALLATION

1.

Refer to Figure 1. 

Place power/blower unit into housing so that mounting

plate's tabs insert into slots in housing.

2. Press other end of mounting plate down until it is firmly seated over scroll and

plug-in receptacles.

3. Secure mounting plate to housing with provided screw.
4. Insert motor plug into junction box receptacle.

COMPLETING INSTALLATION

1. Insert lamp plug into junction box receptacle and secure reflector assembly to

motor frame with wing nut provided.

2. Install lamps 100 watt (maximum) for light, and 7 watt (maximum) for 

night light (Night light not provided on 8664RP).

3. Squeezing the grille assembly's mounting springs together, insert springs into

slots on both sides of housing.

4. Press grille assembly firmly into place against ceiling.

INSTALLATION IN EXISTING CONSTRUCTION

Locate fan between ceiling joists.
Plan ducting wiring before proceeding with installation. 

Refer to Figure 4 for

wiring. CAUTION: Check area above planned location to be sure that:

1. Ducting can be installed.
2. Wiring can be run to the planned location.
3. No wiring or other obstruction might interfere with installation.

I

NSTALLATION FROM ACCESSIBLE AREA ABOVE

1. After determining desired location for fan, drill a small hole in the ceiling. Place

a coat hanger or other stiff wire up through hole to help in locating from above.

2. Place fan housing on top of ceiling surface and use the housing as a template

to mark area to be cut out. Cut round hole 13

1

8

" in diameter for rough opening.

3. After cutting out opening, mount housing in the opening using the hanger bars

provided.

A. Insert hanger bars in slots in housing.
B. Position housing in opening so that bottom of housing is flush with ceiling.
C. Use screws or nails (not provided) to secure hanger bars to ceiling joists.

4. Install ducting and wiring as described above.

INSTALLATION FROM AREA BELOW CEILING

Note: If you do not have access to the area above the installation location, make
sure that the installation will not interfere with existing wiring, plumbing, etc. and
that the wiring and ducting can be run to the desired location. It will be necessary
to use flexible duct when installing the unit from below.

1. The fan must be mounted between ceiling joists. Decide where you want to

locate the fan, and then determine where the nearest joists are.

Locating Joists –

Lightly tap the ceiling. A hollow sound means no joist; a

solid sound means a joist is present. To be sure you have located a joist, drill a
small hole (1/16") and probe into the ceiling with a wire.

2. Locate the joists. Drill a starter hole in the ceiling between the joists.
3. To exactly locate the edge of joist, saw a line from hole to joist.
4.

Refer to page 1. 

Remove power/blower unit from housing.

5. Use the housing pan as a template to mark cutout: place pan centered

between joist and trace around pan.

6. Make cutout along outside of marked line.
7.

Refer to Figure 5. 

Install 2 x 4 cleats to both ceiling joists. In some cases it

may be necessary to use more than a single cleat on one side. The distance
between cleats must be at least 9

1

8

" but not more than 10". 

8. Remove side wiring knockout and insert and secure an approved box

connector into the wiring entrance hole.

9. Use pliers to bend both mounting tabs as flush as possible to the side of the

housing.

10. Install duct collar.
11. String wiring through box connector and connect 4" flexible duct to duct collar.
12. Carefully push ductwork and wiring back into cutout. Place housing into

cutout.

13. Use wood screws to secure housing to cleats through four holes in housing's

pan. Make sure pan is flush to finished ceiling.

14. Install Power/Blower Unit and complete installation.

FIGURE 5

FIGURE 6

11-1/2"

9-1/8" - 10"

Joist

2"

4"

5-3/4"

4" Flexible
Duct

120vAC
House Wiring

Duct
Collar

Wiring
Knockout

Bend
Mounting
Tabs
Flush To
Side of
Housing

Mounting
Holes

CLEANING AND RELAMPING

1. Pull grille assembly away from ceiling.
2. Squeezing the grille assembly's mounting springs together, remove grille

assembly from housing to expose socket for relamping.

3. Clean grille and lens assembly using a mild soap and water solution.

Assemblies with wood frames should not be immersed.

4. Replace grille assembly flat against ceiling after cleaning or relamping.

Cleat

Содержание 8663RP

Страница 1: ... shower it must be marked as appropriate for the application F NEVER place a switch where it can be reached from a tub or shower G For installation in sloped ceilings up to 12 12 pitch H Ductwork must point up FOR BEST RESULTS When installing the Exhaust Fan Light in a new construction site install housing during the rough in construction of the building The blower unit reflector and grille should...

Страница 2: ...be properly grounded IMPORTANT Use wire suitable for 90 C 1 Run 120vAC house wiring from wall switches to fan location neutral white ground bare copper and three switched hot leads See Figure 4 2 Insert and secure an approved box connector into wiring entrance hole 3 Pull wires through box connector and into junction box Tighten box connector 4 Refer to Figure 4A For 8663RP or 8673RP Connect white...

Страница 3: ...g wiring plumbing etc and that the wiring and ducting can be run to the desired location It will be necessary to use flexible duct when installing the unit from below 1 The fan must be mounted between ceiling joists Decide where you want to locate the fan and then determine where the nearest joists are Locating Joists Lightly tap the ceiling A hollow sound means no joist a solid sound means a jois...

Страница 4: ...ncastrée C Lorsque vous coupez ou percez dans un mur ou un plafond n abîmez pas le câblage électrique ou tout autre installation encastrée D Les ventilateurs avec gaine doivent toujours avoir une une évacuation extérieure E Si cette unité doit être installé au dessus d une baignoire ou d une douche une stipulation spécifique pour cette utilisation est nécessaire F N installez JAIMAIS un interrupte...

Страница 5: ...collier de gaine du ventilateur CABLAGE Tout le câblabe doit respecter les règlements locaux et le ventilateur doit être convenablement relié à la terre IMPORTANT Utiliser un câble qui supporte une chaleur de 75 C 1 Amener un câble de 120 V CA avec terre de l interrupteur mural à l emplacement du ventilateur Voir Figure 4 2 Placer un raccord agréé dans le trou d entrée du câblage 3 Tirer les câble...

Страница 6: ...on inclus pour fixer les barreaux de montage aux solives du plafond 4 Procédez à l installation des conduits d aération et du câblage comme décrit ci dessus INSTALLATION À PARTIR DE LA ZONE SE TROUVANT EN DESSOUS DU PLAFOND NOTA Si vous n avez pas accès à la zone se trouvant au dessus de l endroit d installation veuillez vous assurer que l installation ne viendra pas interférer avec le câblage et ...

Страница 7: ...le la lámpara ventilador aspirante en una construcción nueva instale la caja durante la etapa de enterramiento de la instalación eléctrica de la construcción La unidad de potencia el reflector y la rejilla deben de instalarse después de que el techo acabado esté en su sitio Consulte las instrucciones de la página 7 para instalar la lámpara ventilador aspirante en un edificio acabado existente PLAN...

Страница 8: ...ubicación del ventilador neutro blanco puesto a tierra cobre desnudo y tres conductores conmutados con corriente Vea la Figura 4 2 Inserte y fije el conectador de caja aprobado en el agujero de entrada del cableado 3 Tire de los cables a través del conectador de caja y dentro de la caja de empalme Aprete el conectador de caja 4 Consulte la Figura 4A para modelo 8663RP o 8673RP Conecte los cables b...

Страница 9: ...e plomería etc y que tanto los conductos como el cableado puedan traerse hasta el lugar desado Será necesario usar conductos flexibles cuando la unidad se instala desde abajo 1 El ventilador se puede montar entre viguetas del techo Decida dónde quiere colocar el ventilador y luego determine dónde están las viguetas más cercanas Localización de las viguetas Golpee ligeramente el techo Un sonido hue...

Страница 10: ...arranty lasts so the above limitation may not apply to you NUTONE S OBLIGATION TO REPAIR OR REPLACE AT NUTONE S OPTION SHALL BE THE PURCHASER S SOLE AND EXCLUSIVE REMEDY UNDER THIS WARRANTY NUTONE SHALL NOT BE LIABLE FOR INCIDENTAL CONSEQUENTIAL OR SPECIAL DAMAGES ARISING OUT OF OR IN CONNECTION WITH PRODUCT USE OR PERFORMANCE Some states do not allow the exclusion or limitation of incidental or c...

Страница 11: ...RP 86933 000 3 32787 MOTOR ISOLATION MOUNT 8663RP 8673RP 8664RP 32787 000 4 32788 GROUND CLIP 8663RP 8673RP 8664RP 32788 000 5 51919 BLOWER WHEEL 8663RP 8673RP 8664RP 5900A 000 NOTE Always order by current part number NuTone Attn Parts Department 4820 Red Bank Rd Cincinnati OH 45227 1599 Phone 513 527 5426 Fax 513 527 5173 8663RP 8673RP 8664RP I I 19 4 7 8 1 5 4 3 2 6 EARLY PRODUCTION 12 9 11 13 1...

Страница 12: ...461B GRILLE LENS ASSEMBLY 8663RP 8664RP 0461B 000 11b 0462B GRILLE LENS BEZEL ASSEMBLY 8673RP 0462B 000 12 85968 GRILLE SPRING ASSEMBLY 8663RP 8673RP 8664RP 85968 000 13 85937 LENS 8663RP 8673RP 8664RP 85937 000 14 57000 GRILLE SPRING SET 8663RP 8673RP 8664RP 0444A 000 15 16133 WING NUT 8663RP 8673RP 8664RP 16133 000 16 10034 FAN RECEPTACLE 8663RP 8673RP 8664RP 10034 000 17 36892 LIGHT RECEPTACLE ...

Отзывы: