READ & SAVE THESE INSTRUCTIONS!

INSTALLATION INSTRUCTIONS

Bathroom Exhaust
Fan/Light Combination

Suitable for use in insulated ceilings.
WARNING: To reduce the risk of fire or electrical shock, do not use this
fan with any solid-state speed control device. Do not install in a ceiling
insulated to a value greater than R-40.

IMPORTANT SAFETY INSTRUCTIONS

WARNING – TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR
INJURY TO PERSONS, OBSERVE THE FOLLOWING:

A. Use this unit only in the manner intended by the manufacturer. 

If you have questions, contact the manufacturer.

B. Before servicing or cleaning unit, switch power off at Service Panel and

lock Service Panel to prevent power from being switched on accidentally.
When the service disconnecting means cannot be locked, securely fasten
a prominent warning device, such as a tag, to the service panel.

CAUTION:

For general ventilating use only. Do not use to exhaust hazardous or

explosive materials and vapors.

INSTALLATION INSTRUCTIONS

WARNING – TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR
INJURY TO PERSONS, OBSERVE THE FOLLOWING:

A. Installation work and electrical wiring must be done by qualified person(s)

in accordance with all applicable codes and standards, including fire-rated
construction.

B. Sufficient air is needed for proper combustion and exhausting of gases

through the flue (chimney) of fuel burning equipment to prevent back
drafting. Follow the heating equipment manufacturer's guideline and safety
standards such as those published by the National Fire Protection
Association (NFPA), 
and the American Society for Heating, Refrigeration and Air Conditioning
Engineers (ASHRAE), and the local code authorities.

C. When cutting or drilling into wall or ceiling, do not damage electrical wiring

and other hidden utilities.

D. Ducted fans must always be vented to the outdoors.
E. If this unit is to be installed over a tub or shower, it must be marked as

appropriate for the application.

F. NEVER place a switch where it can be reached from a tub or shower.
G. For installation in sloped ceilings up to 12/12 pitch.
H. Ductwork must point up.

FOR BEST RESULTS

When installing the Exhaust Fan/Light in a new construction site, install

housing during the rough-in construction of the building. The blower unit,
reflector and grille should be installed after the finished ceiling is in place.

Refer to instructions on page 3

to install the Exhaust Fan/Light in an

existing finished building.

PLANNING DUCTWORK AND WIRING

1. Use 4" round duct.
2. Plan duct run from discharge opening of fan to the outside. For best fan

performance, make duct run as short as possible and use minimum
number of elbows.

3. Use optional NuTone ducting accessories as needed.

Wiring
Knockouts

FIGURE 1

MODEL: 8663RP, 8673RP, 8664RP

Suitable for use in shower or tub enclosure when used
with GFI protected branch circuit.

IMPORTANT: 

Use wire suitable for 90°C.

Plan to run 120vAC house wiring (with ground) from power source, through

wall switches, to junction box in fan. For separate control of fan, light, and
night light three wall switches are required. See NuTone Catalog for accessory
switches. For separate control of fan, light, and night light, five conductors are
needed between the wall switch box and the fan's junction box. (Night light
not provided on 8664RP).

INSTALLATION IN A NEW
CONSTRUCTION SITE

PREPARATION

1.

Refer to Figure 1. 

Remove power unit/blower assembly from housing.

A. Unplug power unit.
B. Remove screw (located next to plug-in receptacle) which holds

power/blower unit mounting plate in place. Save screw.

C. Lift mounting plate at end near the plug-in receptacle until blower

wheel clears the scroll.

D. Remove plate by pulling its tabs out of slots in housing. Set

power/blower unit aside until needed.

2. Remove one of the wiring knockouts from housing.

Housing

Scroll

Slots

Power/Blower

Unit

Reflector
Assembly

Night Light
Socket
(not provided
on 8664RP)

Wing Nut

Grille/Lens

Assembly

Mounting

Springs (2)

Duct
Collar

Tabs

Содержание 8663RP

Страница 1: ... shower it must be marked as appropriate for the application F NEVER place a switch where it can be reached from a tub or shower G For installation in sloped ceilings up to 12 12 pitch H Ductwork must point up FOR BEST RESULTS When installing the Exhaust Fan Light in a new construction site install housing during the rough in construction of the building The blower unit reflector and grille should...

Страница 2: ...be properly grounded IMPORTANT Use wire suitable for 90 C 1 Run 120vAC house wiring from wall switches to fan location neutral white ground bare copper and three switched hot leads See Figure 4 2 Insert and secure an approved box connector into wiring entrance hole 3 Pull wires through box connector and into junction box Tighten box connector 4 Refer to Figure 4A For 8663RP or 8673RP Connect white...

Страница 3: ...g wiring plumbing etc and that the wiring and ducting can be run to the desired location It will be necessary to use flexible duct when installing the unit from below 1 The fan must be mounted between ceiling joists Decide where you want to locate the fan and then determine where the nearest joists are Locating Joists Lightly tap the ceiling A hollow sound means no joist a solid sound means a jois...

Страница 4: ...ncastrée C Lorsque vous coupez ou percez dans un mur ou un plafond n abîmez pas le câblage électrique ou tout autre installation encastrée D Les ventilateurs avec gaine doivent toujours avoir une une évacuation extérieure E Si cette unité doit être installé au dessus d une baignoire ou d une douche une stipulation spécifique pour cette utilisation est nécessaire F N installez JAIMAIS un interrupte...

Страница 5: ...collier de gaine du ventilateur CABLAGE Tout le câblabe doit respecter les règlements locaux et le ventilateur doit être convenablement relié à la terre IMPORTANT Utiliser un câble qui supporte une chaleur de 75 C 1 Amener un câble de 120 V CA avec terre de l interrupteur mural à l emplacement du ventilateur Voir Figure 4 2 Placer un raccord agréé dans le trou d entrée du câblage 3 Tirer les câble...

Страница 6: ...on inclus pour fixer les barreaux de montage aux solives du plafond 4 Procédez à l installation des conduits d aération et du câblage comme décrit ci dessus INSTALLATION À PARTIR DE LA ZONE SE TROUVANT EN DESSOUS DU PLAFOND NOTA Si vous n avez pas accès à la zone se trouvant au dessus de l endroit d installation veuillez vous assurer que l installation ne viendra pas interférer avec le câblage et ...

Страница 7: ...le la lámpara ventilador aspirante en una construcción nueva instale la caja durante la etapa de enterramiento de la instalación eléctrica de la construcción La unidad de potencia el reflector y la rejilla deben de instalarse después de que el techo acabado esté en su sitio Consulte las instrucciones de la página 7 para instalar la lámpara ventilador aspirante en un edificio acabado existente PLAN...

Страница 8: ...ubicación del ventilador neutro blanco puesto a tierra cobre desnudo y tres conductores conmutados con corriente Vea la Figura 4 2 Inserte y fije el conectador de caja aprobado en el agujero de entrada del cableado 3 Tire de los cables a través del conectador de caja y dentro de la caja de empalme Aprete el conectador de caja 4 Consulte la Figura 4A para modelo 8663RP o 8673RP Conecte los cables b...

Страница 9: ...e plomería etc y que tanto los conductos como el cableado puedan traerse hasta el lugar desado Será necesario usar conductos flexibles cuando la unidad se instala desde abajo 1 El ventilador se puede montar entre viguetas del techo Decida dónde quiere colocar el ventilador y luego determine dónde están las viguetas más cercanas Localización de las viguetas Golpee ligeramente el techo Un sonido hue...

Страница 10: ...arranty lasts so the above limitation may not apply to you NUTONE S OBLIGATION TO REPAIR OR REPLACE AT NUTONE S OPTION SHALL BE THE PURCHASER S SOLE AND EXCLUSIVE REMEDY UNDER THIS WARRANTY NUTONE SHALL NOT BE LIABLE FOR INCIDENTAL CONSEQUENTIAL OR SPECIAL DAMAGES ARISING OUT OF OR IN CONNECTION WITH PRODUCT USE OR PERFORMANCE Some states do not allow the exclusion or limitation of incidental or c...

Страница 11: ...RP 86933 000 3 32787 MOTOR ISOLATION MOUNT 8663RP 8673RP 8664RP 32787 000 4 32788 GROUND CLIP 8663RP 8673RP 8664RP 32788 000 5 51919 BLOWER WHEEL 8663RP 8673RP 8664RP 5900A 000 NOTE Always order by current part number NuTone Attn Parts Department 4820 Red Bank Rd Cincinnati OH 45227 1599 Phone 513 527 5426 Fax 513 527 5173 8663RP 8673RP 8664RP I I 19 4 7 8 1 5 4 3 2 6 EARLY PRODUCTION 12 9 11 13 1...

Страница 12: ...461B GRILLE LENS ASSEMBLY 8663RP 8664RP 0461B 000 11b 0462B GRILLE LENS BEZEL ASSEMBLY 8673RP 0462B 000 12 85968 GRILLE SPRING ASSEMBLY 8663RP 8673RP 8664RP 85968 000 13 85937 LENS 8663RP 8673RP 8664RP 85937 000 14 57000 GRILLE SPRING SET 8663RP 8673RP 8664RP 0444A 000 15 16133 WING NUT 8663RP 8673RP 8664RP 16133 000 16 10034 FAN RECEPTACLE 8663RP 8673RP 8664RP 10034 000 17 36892 LIGHT RECEPTACLE ...

Отзывы: