background image

BE0004A

BLK

VENT
SWITCH

BLU

BLK

WH T

WH T

WH T

LIGHT

(WHITE)

GRD

VENT

(BLACK)

UNIT

SWITCH BOX

LIGHT
SWITCH

LINE

IN

BLK

RED

WHT

GRD

SCHEMATIC WIRING DIAGRAM

FINISH THE  INSTALLATION

INSTALL THE  DUCTWORK

NOTE:

 The duct connector has a counter-balanced damper 

flap. The flap will be “open” approx. 1” when duct connector 
is attached to housing. This design permits insulation to be 
in direct contact with fan/light housing per UL (Underwriters 
Laboratories) standards. The slightest backdraft, however, 
will close the damper flap, preventing air from entering unit 
or finished space.

CONNECT THE WIRING

1.  Connect 4” round 

duct to damper/
duct connector 
and extend duct 
to outside through 
a roof or wall cap. 
Check damper to 
make sure that it 
opens freely. Tape 
all duct connections to make them secure and air tight.

1.  Wire unit as shown. Re-install wiring plate removed in 

Step 2 under “PREPARE THE HOUSING”.

2.  Run electrical cable as direct as possible to unit. Do not allow 

cable to touch sides or top of unit after installation is complete. 

3. Locate grille pan 

over fan housing and 
connect light plug into 
WHITE receptacle in fan 
housing.

4. Attach grille pan to 

mounting brackets with 
(2) screws (included).

5. Thread rod onto 

threaded stud in center 
of grille pan. Tighten rod 
securely.

SWITCH BOX

LIGHT

FAN

DUAL CONTROL

(purchase separately)

WHITE

BLACK

RED

GROUND
(bare)

120 VAC LINE IN

BLUE

BLACK

RECEPTACLE

(FAN)

WHITE

RECEPTACLE

(LIGHT)

4. Place housing in 

opening so that 
its bottom edge is 
flush  with finished 
ceiling. Screw 
housing to joist 
through holes in 
housing as shown.

5. Seal between 

ceiling material and 
housing to prevent 
air leakage.

SEAL BETWEEN CEILING

MATERIAL & HOUSING

MOUNTING SCREWS

2. Attach grille pan 

mounting brackets to 
housing with screws 
(included). Make sure 
brackets face inward.

1. Re-install blower 

assembly removed 
in Step 1 under 
“PREPARE THE 
HOUSING”. Plug blower 
into BLACK receptacle.

BD0031

BD0030

6. Install bulbs. Use 13-watt 

(maximum), GU24 type, 
fluorescent bulbs. 

7.  Place washers and glass 

shade over mounting 
rod and align shade over 
grille pan. Secure shade 
to grille pan with washer 
and finial nut as shown.

8. Restore electrical power 

and check operation of 
the unit.

METAL

WASHER

FELT

WASHERS

FELT

WASHER

FINIAL

NUT