BE0004A
BLK
VENT
SWITCH
BLU
BLK
WH T
WH T
WH T
LIGHT
(WHITE)
GRD
VENT
(BLACK)
UNIT
SWITCH BOX
LIGHT
SWITCH
LINE
IN
BLK
RED
WHT
GRD
SCHEMATIC WIRING DIAGRAM
FINISH THE INSTALLATION
INSTALL THE DUCTWORK
NOTE:
The duct connector has a counter-balanced damper
flap. The flap will be “open” approx. 1” when duct connector
is attached to housing. This design permits insulation to be
in direct contact with fan/light housing per UL (Underwriters
Laboratories) standards. The slightest backdraft, however,
will close the damper flap, preventing air from entering unit
or finished space.
CONNECT THE WIRING
1. Connect 4” round
duct to damper/
duct connector
and extend duct
to outside through
a roof or wall cap.
Check damper to
make sure that it
opens freely. Tape
all duct connections to make them secure and air tight.
1. Wire unit as shown. Re-install wiring plate removed in
Step 2 under “PREPARE THE HOUSING”.
2. Run electrical cable as direct as possible to unit. Do not allow
cable to touch sides or top of unit after installation is complete.
3. Locate grille pan
over fan housing and
connect light plug into
WHITE receptacle in fan
housing.
4. Attach grille pan to
mounting brackets with
(2) screws (included).
5. Thread rod onto
threaded stud in center
of grille pan. Tighten rod
securely.
SWITCH BOX
LIGHT
FAN
DUAL CONTROL
(purchase separately)
WHITE
BLACK
RED
GROUND
(bare)
120 VAC LINE IN
BLUE
BLACK
RECEPTACLE
(FAN)
WHITE
RECEPTACLE
(LIGHT)
4. Place housing in
opening so that
its bottom edge is
flush with finished
ceiling. Screw
housing to joist
through holes in
housing as shown.
5. Seal between
ceiling material and
housing to prevent
air leakage.
SEAL BETWEEN CEILING
MATERIAL & HOUSING
MOUNTING SCREWS
2. Attach grille pan
mounting brackets to
housing with screws
(included). Make sure
brackets face inward.
1. Re-install blower
assembly removed
in Step 1 under
“PREPARE THE
HOUSING”. Plug blower
into BLACK receptacle.
BD0031
BD0030
6. Install bulbs. Use 13-watt
(maximum), GU24 type,
fluorescent bulbs.
7. Place washers and glass
shade over mounting
rod and align shade over
grille pan. Secure shade
to grille pan with washer
and finial nut as shown.
8. Restore electrical power
and check operation of
the unit.
METAL
WASHER
FELT
WASHERS
FELT
WASHER
FINIAL
NUT
Page 3
MODEL 788CHNTC