background image

INSTALLATION INSTRUCTIONS

READ & SAVE THESE INSTRUCTIONS!

Bathroom Exhaust
Fan/Fluorescent Light
Combination

MODEL: 769RF

FOR BEST RESULTS

When installing the Exhaust Fan/Light in a new

construction site, install housing during the rough-in
construction of the building. The blower unit and grille should
be installed after the finished ceiling is in place.

To install the Exhaust Fan/Light in an existing finished

building see instructions page 4.

FIGURE 1

IMPORTANT SAFETY INSTRUCTIONS

WARNING: TO REDUCE THE RISK OF FIRE.

ELECTRIC SHOCK, OR INJURY TO PERSONS,
OBSERVE THE FOLLOWING:

A. Use this unit only in the manner intended by the

manufacturer. If you have questions, contact the
manufacturer.

B. Before servicing or cleaning unit, switch power off at

service panel and lock service panel to prevent power from
being switched on accidentally.
When the service disconnecting means cannot be locked,
securely fasten a prominent warning device, such as a tag, 
to the service panel.

CAUTION:

For general ventilating use only. Do not use to exhaust

hazardous or explosive materials and vapors.

INSTALLATION INSTRUCTIONS

WARNING: TO REDUCE THE RISK OF FIRE,

ELECTRIC SHOCK, OR INJURY TO PERSONS,
OBSERVE THE FOLLOWING:

A. Installation work and electrical wiring must be done by

qualified person(s) in accordance with all applicable codes
and standards, including fire-rated construction.

B. Sufficient air is needed for proper combustion and

exhausting of gases through the flue (chimney) of fuel
burning equipment to prevent back drafting. Follow the
heating equipment manufacturer's guideline and safety
standards such as those published by the National Fire
Protection Association (NFPA), and the American Society
for Heating, Refrigeration and Air Conditioning Engineers
(ASHRAE), and the local code authorities.

C. When cutting or drilling into wall or ceiling, do not damage

electrical wiring and other hidden utilities.

D. Ducted fans must always be vented to the outdoors.
E. If this unit is to be installed over a tub or shower, it must be

marked as appropriate for the application.

F. NEVER place a switch where it can be reached from a tub

or shower.

The exhaust fan consists of the housing, power unit/blower
assembly (motor, wheel, mounting plate,) grille/lens
assembly, reflector/lamp plug assembly (lamps not
furnished) and duct collar.

WARNING: To reduce the risk of fire or electric shock,
do not use this fan with any solid-state speed control
device.

Not for use in kitchens.

For installation in sloped ceilings up to 12/12 pitch.

Ductwork must point up.

DUCT COLLAR

HOUSING

SLOTS

TABS

POWER UNIT/
BLOWER
ASSEMBLY

GRILLE

REFLECTOR

LENS

• SUITABLE FOR USE OVER A TUB OR 

SHOWER WHEN INSTALLED IN A G.F.C.I. 
PROTECTED BRANCH CIRCUIT.

• DO NOT INSTALL IN A CEILING INSULATED TO A

VALUE GREATER THAN R-40.

Содержание 769RF

Страница 1: ...ccordance with all applicable codes and standards including fire rated construction B Sufficient air is needed for proper combustion and exhausting of gases through the flue chimney of fuel burning eq...

Страница 2: ...NG THE HOUSING USING SIDE MOUNTING TABS Refer to Figure 2 1 Locate housing next to ceiling joist 2 Use wood screws not provided to loosely attach housing to ceiling joist through keyhole slots in moun...

Страница 3: ...BLOWER UNIT INSTALLATION Refer to Figure 7 1 Place power blower unit into housing so that mounting plate s tabs insert into slots in housing 2 Press other end of mounting plate down until it is firml...

Страница 4: ...PRESS OR IMPLIED INCLUDING BUT NOT LIMITED TO IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE During this one year period NuTone will at its option repair or replace without...

Страница 5: ...EEL 769RF 82403 000 4 87549 REFLECTOR ASSEMBLY 769RF 87549 000 5 30652 DUCT ADAPTER ASSEMBLY 769RF 30652 000 6 85315 GRILLE AND LENS ASSEMBLY 769RF 85315 000 7 16133 WING NUT 769RF 16133 000 8 10034 F...

Страница 6: ...s ou des vapeurs INSTRUCTIONS D INSTALLATION MISE EN GARDE POUR REDUIRE LE RISQUE D INCENDIE D ELECTROCUTION OU DE BLESSURE PHYSIQUE RESPECTEZ LES OBSERVATIONS SUIVANTES A L installation et les c blag...

Страница 7: ...f rer la figure 2 1 Placez le bo tier c t de la solive du plafond 2 Utilisez des visses en bois non fournies pour attacher le bo tier l chement la solive du plafond travers les fentes dans les pattes...

Страница 8: ...rer la figure 7 1 Placez l unit de courant ventilateur dans le bo tier pour monter les pattes de la plaque dans les fentes du bo tier 2 Poussez l autre extr mit de la plaque de montage vers le bas ju...

Страница 9: ...pour une p riode d un 1 an compter de la date d achat AUCUNE AUTRE GARANTIE IMPLICITE OU EXPRESSE N EST DONN E Y COMPRIS MAIS SANS S Y LIMITER GARANTIE DE MARCHANDIBILIT OU D ADAPTATION UN USAGE PARTI...

Страница 10: ...RF 82403 000 4 87549 ASSEMBLAGE DU REFLECTEUR 769RF 87549 000 5 30652 ASSEMBLAGE DE L ADAPTATEUR DE LA GAINE 769RF 30652 000 6 85315 ASSEMBLAGE GRILLE ET LENTILLE 769RF 85315 000 7 16133 ECROU A AILET...

Отзывы: