IMPORTANT SAFETY INSTRUCTIONS

WARNING: TO REDUCE THE RISK OF FIRE, 

ELECTRIC SHOCK, OR INJURY TO PERSONS, OBSERVE THE
FOLLOWING:

A. Use this unit only in the manner intended by the manufacturer. If you

have questions, contact the manufacturer.

B. Before servicing or cleaning unit, switch power off at service panel and

lock service panel to prevent power from being switched on accidentally.
When the service disconnecting means cannot be locked, securely
fasten a prominent warning device, such as a tag, to the service panel.

CAUTION:

For general ventilating use only. Do not use to exhaust hazardous or

explosive materials and vapors

.

INSTALLATION INSTRUCTIONS

WARNING: TO REDUCE THE RISK OF FIRE, 

ELECTRIC SHOCK, OR INJURY TO PERSONS, OBSERVE THE
FOLLOWING:

A. Installation work and electrical wiring must be done by qualified

person(s) in accordance with all applicable codes and standards,
including fire-rated construction.

B. Sufficient air is needed for proper combustion and exhausting of gases

through the flue (chimney) of fuel burning equipment to prevent back
drafting. Follow the heating equipment manufacturer's guideline and
safety standards such as those published by the National Fire
Protection Association (NFPA), and the American Society for Heating,
Refrigeration and Air Conditioning Engineers (ASHRAE), and the local
code authorities.

C. When cutting or drilling into wall or ceiling, do not damage electrical

wiring and other hidden utilities.

D. Ducted fans must always be vented to the outdoors.
E. If this unit is to be installed over a tub or shower, it must be marked as

appropriate for the application.

F. NEVER place a switch where it can be reached from a tub or shower.

Unit consists of the housing, power unit/blower assembly (motor, wheel
mounting plate, grille, reflector, lens and duct collar).

• WARNING: To reduce the risk of fire or electric shock, do not use

this fan with any solid-state speed control device.

• WARNING: To reduce the risk of shock, disconnect power before

servicing.

Not for use in kitchens.

Do not install in a ceiling insulated to a value greater than R-40.

For installation in sloped ceilings up to 7/12 pitch.

Ductwork must point up.

FOR BEST RESULTS

For new construction install the housing during the rough-in stage of

construction. The blower unit, light and grille should be installed after the
finished ceiling is in place.

To install the Exhaust Fan-Light in an existing finished building requires

an accessible area (attic or crawl space) above the planned location.

PLANNING DUCTWORK AND WIRING

DUCTWORK

1. Use 4" round duct.
2. Plan to run duct from the fan's discharge opening to the outside. For

best fan performance, make duct run as short as possible and use
minimum number of elbows.

3. Use optional NuTone ducting accessories as needed (refer to NuTone's

catalog for a complete listing of optional accessories).

WIRING

Plan to run 120vAC house wiring (with ground) from a power source,

through a standard wall switch or an optional NuTone double FAN/LIGHT
switch, to the junction box in the Fan-Light's housing.

INSTALLATION IN A NEW
CONSTRUCTION SITE

PREPARATION

1. Unplug the power unit.
2. 

Refer to Figure 1.

Remove power unit/blower assembly from the

housing. Remove screw and pull power unit assembly tabs out of slots
in housing. Set unit aside until needed.

3. Remove one of the wiring knockouts from housing.

MOUNTING THE HOUSING

USING SIDE MOUNTING TABS

Refer to Figure 2.

1. Locate housing next to ceiling joist.
2. Use wood screws (not provided) to loosely attach housing to ceiling

joist through keyhole slots in mounting tabs.

3. Adjust housing so that it will be flush with the finished ceiling.
4. When housing is properly adjusted, tighten screws in slots.

USING HANGER BARS

(Hanger bars sold separately, order model HB4)
Refer to Figure 3.

1. Insert hanger bars in slots provided in housing.
2. Locate fan housing between ceiling joists so that bottom of fan housing

is even with the planned finished ceiling.

3. Use screws or nails to secure mounting brackets to ceiling joists.

INSTALLING DUCTWORK

1. 

Refer to Figure 1.

Place duct collar over flanges at discharge opening

of fan. Secure collar by snapping tabs into slots in flanges.

2. 

Refer to Figure 4.

Run 4" round duct from outside to fan's discharge

opening.

3. Connect duct to duct collar.

INSTALLATION INSTRUCTIONS

READ & SAVE THESE INSTRUCTIONS!

Ceiling Fan-Light

MODEL: 763RLN & 769RL

SUITABLE FOR USE OVER TUB OR SHOWER ENCLOSURE 
WHEN INSTALLED IN A GFCI PROTECTED BRANCH CIRCUIT.

Содержание 763RLN

Страница 1: ...pitch Ductwork must point up FOR BEST RESULTS For new construction install the housing during the rough in stage of construction The blower unit light and grille should be installed after the finished ceiling is in place To install the Exhaust Fan Light in an existing finished building requires an accessible area attic or crawl space above the planned location PLANNING DUCTWORK AND WIRING DUCTWORK...

Страница 2: ...f its products that such products will be free from defects in materials or workmanship for a period of one 1 year from the date of original purchase THERE ARE NO OTHER WARRANTIES EXPRESS OR IMPLIED INCLUDING BUT NOT LIMITED TO IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE During this one year period NuTone will at its option repair or replace without charge any product...

Страница 3: ...tale la caja durante la etapa de enterramiento de la instalación eléctrica de la construcción La unidad del soplador la lámpara y la rejilla deben de instalarse después de que el techo acabado esté en su sitio Para instalar la Lámpara Ventilador Aspirante en un edificio acabado ya existente se requiere un área accesible ático o sótano de pequeña altura que queda entre el primer piso y el terreno n...

Страница 4: ...re un agujero pequeño 1 16 y explore dentro del techo con un cable Deje el cable en el agujero para poder localizarlo en el ático o en el sótano de pequeña altura 2 Localice el agujero en el ático o en el sótano de pequeña altura 3 Utilizando la caja como una plantilla marque el techo para el recorte Dimensiones del recorte 91 8 x 91 8 4 Haga el recorte a lo largo de la línea marcada 5 Consulte Mo...

Страница 5: ...URS RÉSULTATS Dans une nouvelle construction installez l habitacle lors de l étape préléminaire de la construction L unité de ventilation l éclairage et la grille devront être montés après la finition du plafond Pour installer le Ventilateur d Évacuation avec Éclairage dans un bâtiment déjà terminé l installation nécessitera un espace accessible grenier ou espace réduit au dessus de l endroit prév...

Страница 6: ...pour mieux trouver le trou dans le grenier ou l espace réduit 2 Trouvez le trou dans le grenier ou l espace réduit 3 En utilisant l habitacle comme gabarit tracez le plafond pour la découpe Dimensions de découpe 9 1 8 de po 9 1 8 de po 4 Faites la découpe le long du traçage 5 Voir Montage de l Habitacle page 2 Garantie limitée d un an GARANTIE DU PROPRIÉTAIRE NuTone garantie à l acheteur original ...

Страница 7: ...DOUBLE WHITE Blanco BLANC WHITE Blanco BLANC BLACK Negro NOIR 120vAC 120vCA 120v CA GROUND Conexion A Tierra TERRE GROUND Conexion A Tierra TERRE 120vAC 120vCA 120v CA BLACK Negro NOIR BLACK Negro NOIR HANGER BARS SOLD SEPARATELY La Barras De Suspensión Se Vende Por Separado LES BARRES DE SUSPENSION SONT VENDUES SÉPARÉMENT FIGURE 1 FIGURA 1 DUCT COLLAR Collarin Del Conducto COL DE GAINE HOUSING Ca...

Страница 8: ...ASSEMBLY 763RLN 769RL 30652 000 7 85316 GRILLE 763RLN 769RL 85316 000 8 89108 LENS 763RLN 769RL 89108 000 9 16133 WING NUT 763RLN 769RL 16133 000 10 10034 FAN RECEPTACLE 763RLN 769RL 10034 000 11 82304 LIGHT RECEPTACLE 763RLN 769RL 82304 000 NOTE Always order by current part number NuTone Attn Parts Department 4820 Red Bank Rd Cincinnati OH 45227 1599 Phone 513 527 5426 Fax 513 527 5173 763RLN 769...