ERROR
CODE
ERROR TYPE
ERROR DESCRIPTION
RECOMMENDED ACTION
0
OK
During printing, it shows that welding has
been successfully completed.
No action required.
2
AMBIENT
TEMPERATURE
OFF LIMITS
Ambient temperature is either lower than
-10°C or higher than 45°C.
Check that the temperature reading on
the welding unit screen is consistent
with the actual room temperature.
Prevent direct exposure to sunlight. If
the room temperature read by the
welding unit is not correct, contact our
Customer Service Representative staff.
4
SHORT CIRCUIT/
OVERLOAD
Current has exceeded limit
(partial fitting short-circuit or fitting made
by other manufacturers).
Replace fitting.
5
OPEN CIRCUIT
Fitting might be faulty or welding cables
not correctly connected to the fitting.
Check connection to the fitting.
Check connectors efficiency.
6
ADJUSTMENT
Extension cable out of tolerance range.
Check that extension diameter and
length are within the recommended
range of values.
12
MAX
INSIDE
TEMPERATURE
Polyvalent welder inside temperature
over 80°C.
Wait for the welding unit to cool down.
13
POWER FAILURE
A power failure has occurred during
welding.
After restoring normal power input
parameters, wait for the fitting to cool
down completely before repeating the
welding procedure from the start.
22
MANUAL STOP
ESC has been pressed during the
welding cycle.
Wait for the fitting to cool down
completely
before
repeating
the
welding procedure from the start.
23
INPUT VOLTAGE
OFF LIMITS
Input voltage is higher or lower than the
rated operating voltage by 20%.
Make sure that the power source or the
generator are operating efficiently.
101
RAM MEMORY
RAM memory data and date/time not
valid
Internal battery could be flat.
Re-enter date/time and if problem
persists contact customer care
102
WELDING CABLE
BREAK
Welding cable is damaged
Do not weld and replace damaged part.
103
INTERNAL
TEMPERATURE
PROBE
Internal Temperature Probe failure
Contact our After-Sale Service staff.