background image

 

Power Supply 

 
The NM-11ETH can be powered within the range of 10-32 Volt DC. The nominal voltage of 24 Volt DC is advised 

for powering the device in normal operation. 

Power input port features protection for incorrect polarity connection of the supplying voltage and a PTC 

resettable Fuse in case of overload. 
 

Composite Layout 

 

 

 

LED Indicators and Jumper Configuration

 

 

LED indicator 

Jumper 

Setting 

Functionality Description 

LED RX 

J1-1: open 

J1-2: closed 

OFF: No data received/connected in the input port 

Blinking: Data received from input port 

J1-1: closed 

J1-2: open 

OFF: No data received/connected in the expansion connector K5 

Blinking: Data received/connected in the expansion connector K5 

LED TX 

OFF: No data transmitted from RS-422/RS-232 output port 

Blinking: Data transmitted from RS-422/RS-232 output port 

LED 3V3 

ON: 3,3 VDC power  supply section OK 

OFF: Malfunction in the 3.3 VDC power supply section 

Notes: 

1.  Jumper array J1 is used to select between the optically isolated input Port and the expansion connector 

K5. The K5 connector is used to interconnect the NM-11ETH to other nuova marea products (power/data 

connection) 

J1-2 closed: Selects the optically isolated port (connector RX) for input 

J1-1 closed: Selects the K5 expansion connector data lines for input 

J1-1 & J1-2 closed: Not applicable, data corruption may occur 

 

2.  Jumper MD is used for selecting the  service mode (initial firmware programming for the Serial over 

Ethernet interface). It should always be open (default).  

   

nuova marea ltd

 

marine electronics & design 

 

Address: 26 Mirtidiotissis str, Kastella, 18533 Piraeus, Greece  

Tel.: +30.210.4134628, +30.210.4134698, Fax: +30.210.4134814 

website 

www.nuovamarea.com

  support site   

www.nuovamarea.net

  

(c) nuova marea ltd 

 