background image

Confirm it or set the number of the desired program by means of the numerical buttons: by pressing button 
START positioning will start, otherwise the first position, or positions,  to reach will appear on the display of 
position by confirming with ENTER; press ENTER again and visualization will show the second cycle and so 
on.
Then press START button and positining will start from the visualized positioning.
If before pressing START or during the execution of the program  You press again AUTOMATIC button, the 
led , already light up on this button, will start flashing, thus showing that the program will be executed in 
CONTINUOUS mode; at the end of program, it will be carried out again until You press button AUTOMATIC 
and the relative led will stop flashing.
When the positioning of the first programmed cycle has been carried out, according to the installed software , 
PRG 920 awaits that the INCREASE CYCLE contact   closes so many times as programmed in the cycle 
repetitions , in order to position itself according to the second cycle and so on, or in automatic mode after 
positioning of the first cycle has been completed, it passes to the positioning of the second cycle and so on.
When choosing the number of program, in case the selected number   is not accepted, it means that the 
requested program is without any data.
By using button STOP it is possible to interrupt positioning in every moment and the display of cycles and 
programs will start flashing.
By pressing button START it's possible to start the program again.
By pressing again button STOP , the execution of the program will be interrupted and display of programs will 
show the number of  the last executed program,  thus allowing the new execution of  the program  or the 
selection of a new one.
By pressing again button STOP , it is possible to return in manual mode.
In every moment, when the program is being carried out, the display of cycles shows the number of cycle 
which is being executed and the display of programs will show the number of program.

END OF PROGRAM

This   is   a   contact   that   closes   for   about   0,5   seconds   each   time   that   a   program   in   execution   has   been 
concluded , it means it concludes its last cycle.

OK POSITION

Ok position is a contact  that during movements opens and closes after the positioning has been executed. It 
remains open if the positioning has not reached a positive result, in semiautomatic mode if the counter of cuts 
has reached the value prevously setted, in automatic way at the end of each program in programming mode 
and when entering the machine constants.

MANUAL-SEMIAUTOMATIC/AUTOMATIC

This is a contact which opens its own contact when PRG 920 is in MANUAL and SEMIAUTOMATIC mode 
and closes it when positioner is in AUTOMATIC mode.

CYCLE INCREASE

When this input is closed all the programmed repetitions are counted.
At each closing, the counter is increased of one unit.

EXTERNAL START

This input repeats the function of the button placed on the frontal.

EXTERNAL STOP

It repeats the function of the button placed on the frontal , with the only difference that each time this input is 
gated, the positioner returns on manual mode.
This input must be connected to a contact normally closed.

GATING

Gating a contact which closes each time a movement starts and opens about 0,5 seconds after the end of 
the movement.
Each axis may be equipped with this contact.

6

Содержание PRG 920

Страница 1: ...LE POSITIONER PRG 920 MANUAL FOR USE AND PROGRAMMING SOFTWARE TYPE P01 HARDWARE TYPE C01 NUOVA ELETTRONICA s n c Via S Lucia 40 06062 Città della Pieve Perugia IT Tel 39 0578 298066 Fax 39 0578 297007 FRONTAL POSITIONER PRG 920 ...

Страница 2: ...inosity led display 2 digits for the number of program High luminosity led display 2 digits for the number of cycle Water and abrasion proof polycarbonate keyboard with tactile sensitivity Electronical circuit completely realized with CMOS Technology RISC Micro Controller Technology Memory for machine constants and programs on EEPROM thus without buffer battery Memory capacity up to 99 programs ea...

Страница 3: ...INE CONSTANTS for about 5 seconds The cycle display will show the number of parameter whereas the dispaly of position will show the relative value By pressing button ENTER it s possible to read the different parameters and in order to correct or write them press the button of the axis to write on write the requested value press ENTER to memorize and then pass to the following parameter By pressing...

Страница 4: ...xis by means of the relative button thus making its led flashing write the desired position by using numerical buttons When making a mistake press C to cancel the content of the display that will show again 00000 Once the correct value has been written select the other axis if You want to write or deselect it by means of the relative button thus making the led switch off confirm with ENTER to pass...

Страница 5: ...g the beginning of positioning In this condition the led on button START will be on to show that a positioning is taking place If for every reason positioning or positionings if selected axis are more than one doesn t occur within the limits of the programmed tolerance PRG 920 will try to carry it out again max for three times and if also after the last attempt positioning has not been carried out...

Страница 6: ...ogram will be interrupted and display of programs will show the number of the last executed program thus allowing the new execution of the program or the selection of a new one By pressing again button STOP it is possible to return in manual mode In every moment when the program is being carried out the display of cycles shows the number of cycle which is being executed and the display of programs...

Страница 7: ...ed on the machine constants is stored on the counter and this value is the new position of the controlled axis This happens only if the output of 0 of the encoder is not connected to the INPUT 0 Each axis may be equipped with this input 0 ENCODER INPUT Each time this input is gated from the encoder output the value of reset memorized on the machine constants is stored on the counter and this is th...

Страница 8: ...O K OF THE INCREASE CYCLE INPUT MANUAL OUTPUT SEMIAUTOMATIC AUTOMATIC END OF PROGRAM OUTPUT EXTERNAL STOP INPUT NORMALLY OPEN TABLE OF OPTIONS ON EACH SINGLE AXIS Axis X Axis Y THE AXIS REACHES RESET VALUE AFTER EVERY POSITIONING GATING OUTPUT DEVIATION INPUT RESET INPUT 0 ENCODER INPUT 8 ...