User’s guide CANICOM 500 PRO – indice B

7/12

Retro-lightning of the LCD screen

You can light the LCD screen for approximately 6 seconds by pressing briefly the On/Off red button

(approx. ½

second).

How to use the remote control with a CANIBEEP RADIO PRO beeper collar

From the remote control you can:

Locate the dog

: briefly or continuously press the yellow button

on the remote control to activate a beep

sound on the collar whenever your dog is pointing or moving.

Deactivate temporarily the collar

: briefly press (1 to 2 seconds) the yellow button

:the collar is in

stand-by (it is temporarily switched Off: no beep sounds whether the dog is pointing or moving). The red

indicator LED is still flashing to indicate that the collar is not definitely turned Off.

Reactivate the collar after it was temporarily deactivated

: if your collar has been temporarily

deactivated, press the yellow button

, you reactivate your collar on the last selected mode.

Completely switch off the collar

: if you continuously press the yellow button

(approx. 5 seconds),

you will completely switch Off your collar (Warning: you will not be able to remotely reactivate it).

For further information regarding the CANIBEEP RADIO PRO beeper collar
(operation, settings, cautions for use, technical specifications), please read the
user’s guide provided with the collar.

Checking/replacing battery of remote control

Performance (radio range) of the remote control may deteriorate as battery becomes weak. Be prepared to replace

the battery.

To check the condition of the battery, turn On the remote control and look at the battery level indicator on the LCD

screen.

The symbols which appear indicate the following:

Battery fully charged
Weak battery: prepare to replace the battery

Dead battery: your CANICOM 500 PRO switches to safety mode and the system locks up. The battery must be

replaced.

NUM’AXES advises to use the same type and same brand of batteries as those supplied in your new

purchased product. Other brands of batteries may not operate, or may not be completely compatible

with your product. You can purchase the suitable batteries from NUM’AXES or from your distributor.

Replace the old battery with a new one as follows:

On the back of the remote control, unscrew the screw and remove the battery cover.

Remove the old battery.

Insert the new battery (3-V Lithium CR2)

paying attention

to follow polarity indicated on the battery housing

(ref. Diagram 8).

Put the battery cover back in place.

Retighten the screw.

Check the remote control operates correctly.

WARNING

Make sure the polarity is correct

Diagram 8

Replacing battery of CANICOM 500 PRO

Содержание Canicom 500 Pro

Страница 1: ...llator must take precautions when they use CANICOM 500 PRO This device emits some static magnetic fields a magnet is located in the remote control Frequency 869 MHz at 250 mW The device complies with...

Страница 2: ...lar equipped with short contact points 3 V Lithium CR2 battery for the collar CANICOM 500 PRO remote control equipped with a 3 V Lithium CR2 battery screwdriver neon test lamp pair of long contact poi...

Страница 3: ...life of the remote control and receiver collar you should deactivate the units if you are not using them for a long period Activate deactivate the CANICOM training collar A magnet located in the remot...

Страница 4: ...the coding first use of receiver collar or re coding make sure no other person is using his CANICOM 500 PRO or other products from the NUM AXES range close by your receiver collar could accidentally...

Страница 5: ...r by testing the operation of the CANIBEEP RADIO PRO 7 Once you have finished the coding put the top back in place paying attention to the rubber seal It must be clean well positioned in its groove an...

Страница 6: ...the remote control The indicator light on the collar goes from flashing green to permanent red while the stimulations are being sent If you press the C button for more than 8 seconds the collar will...

Страница 7: ...lar operation settings cautions for use technical specifications please read the user s guide provided with the collar Checking replacing battery of remote control Performance radio range of the remot...

Страница 8: ...receiver collar Press the F or C button and modify the level of intensity of the stimulations the test lamp will come on with more or less intensity Getting the best results The training instructions...

Страница 9: ...ildren with reduced physical sensory or mental capabilities or lack of experience and knowledge unless they have been given supervision or instruction concerning use of the appliance by a person respo...

Страница 10: ...r product for service and repair For all repairs please supply the following the complete product the proof or purchase invoice or sales receipt If you omit one of these items the After Sales Service...

Страница 11: ...uctions or not envisioned therein repairs performed by unauthorized persons loss or theft 3 If the product is found to be defective NUM AXES will either decide to repair or to replace it 4 No claim ma...

Страница 12: ...s guide CANICOM 500 PRO indice B 12 12 NUM AXES ZAC des Aulnaies 745 rue de la Bergeresse BP 30157 45161 OLIVET CEDEX FRANCE Tel 33 0 2 38 63 64 40 Fax 33 0 2 38 63 31 00 www numaxes com export numaxe...

Отзывы: