LCD Display
Fault
Possible Cause
Ef
fect on Product
Investigate the Following
Action Required
I
f Fault
Persists
Blank
* No power
* Key switched of
f
* Emergency stop pressed
* Machine will not operate
* Key switched of
f
* Emergency stop pressed
* Switch key on
* Release emergency stop
‘OVER CURRENT’
* Brush over current
* Brush pressure too great.
* Brush current exceeds 32A
* W
rong type of brush for surface
* V
ac. Brush, water &
Detergent motors / pump
will not operate
* Brush LED’
s all flash in
unison until the Pedal is
released
* Release brush pressure
* Change type of brush
* Restart machine
‘UNDER VOL
TS’
* Battery voltage dropped below
21 V
olts
* Left most Battery LED flashes
* Batteries require recharging
* Faulty cell on battery
* Machine will not operate
* Battery leads and connections
* Charge Batteries
* Replace battery (if cell damaged)
‘ T
ANK FULL
’
* W
aste (T
op)
Tank full requires
emptying
* W
aste
Tank Float switch activated
whilst cleaning or of
f-aisle mode
selected
* Faulty Float switch
* V
ac, Brush, water &
Detergent motors / pump
will not operate
* W
aste (T
op)
Tank full LED illuminated
* T
op waste tank full
* Empty W
aste (T
op)
Tank
* Replace float switch
‘INHIBITED’
MACHINE INHIBITED - NO OPERA
TION
Contact Service Agent
To view
TRO 650 / 200T
run-time information turn the key to position (
1
) ‘ON’.
Press the run-time information button to cycle between the dif
ferent modes.
T =
Total run-time.
V =
Vacuum total run-time.
B =
Brush total run-time.
W=
W
ater Pump total run-time.
LCD Display
Содержание TRO 650/200T
Страница 3: ...Machine Overview 13 14 6 12 22 21 18 19 20 16 17 11 10 9 2 3 4 5 6 7 8 15 23 ...
Страница 27: ...EU Declaration of Conformity 27 T 01460 68600 ...
Страница 28: ...Warranty 28 www numatic co uk ...
Страница 29: ...Notes 29 T 01460 68600 ...
Страница 30: ...Notes 30 www numatic co uk ...
Страница 31: ...Notes 31 T 01460 68600 ...