19
for setting temperature, checking & setting parameters, etc.
2.3.2.3 Temperature Setting:
When the wired controller is on, press“
”or“
”
,
the temperature
data on the screen will show up, then press “
”or“
”to add or reduce
,
then press“
” to confirm the
modifying, or after 20 seconds without any operation, it will automatically quit from the temperature
setting, and store the current modified data, press“
” or “
” without stop for over 0.5 second to start
quick adding or substracting.
2.3.2.4 Key locked function:
First press “
”, then press “
” for 3s to enter or exit key locked
function, when “
”symbol show up means wired controller locked.
2.3.2.5 Inquiry running parameters
2.3.5.1 Enter inquiry:
first press “
”then press “
” for 3 s to enter parameters setting status,
temperature display area display parameter number, setting temperature area display parameters
content.
2.3.5.2 Inquiry operation and exit:
after entering running parameters, press “
”or “
”to display
each running parameter; press “
”to exit inquiring parameters status or if there is not any pressing
keys operation will automatically exit inquiring parameters status after 20s.
2.3.2.6 Common parameters setting
1.3.6.1 Enter setting
; first pressing “
” then press “
” for 3 secs,the temperature display area
display “00” and blinking display ,input the password (default password “Fb”),then press “
”or “
”to
add or subtract ,press “
”or “
” to confirm ,if the password is wrong then exit current status ; if the
password is correct then enter parameter modification status ,temperature display area display
parameters number and blinking display ,setting temperature area display parameter content ;
1.3.6.2 Setting operation :
after entering setting parameters, the parameter number blinking
display ,press “
”or “
”switch line to display each setting parameters number ,then press “
”the
parameters content blinking display ,press “
”or “
” to modify current content ,after finishing press
“
” to save current modification then back to parameters number display status .
1.3.6.3 Exit setting;
press “
”to exit parameters setting status or if there is not any pressing keys
Содержание New Energy BKDX30-95I/1/S
Страница 4: ...3 BKDX50 200I 1 S BKDX60 220I 1 S BKDX80 280I 1 S...
Страница 6: ...5 3 3 BKDX80 280I 1 S 1521 5 1556 5 587 592 620 104 2 964 6 G1 5 G1 5 62 1507 591 8 1052...
Страница 11: ...10 2 Connection diagram 1 BKDX30 95I 1 S 2 BKDX50 200I 1 S BKDX60 220I 1 S BKDX80 280I 1 S...
Страница 13: ...12 4 Circuit diagram 1 BKDX30 95I 1 S 220V 2 BKDX50 200I 1 S BKDX60 220I 1 S 220V...