Button instruction
Fault code and instruction table
Code No. Fault Name
E01
Outdoor unit current protection
E02
Flow switch protection
E03
EEPROM error indication (indoor board) / EEPROM error indication (operation
panel)
E04
Return water temperature over high when heating or output water temperature
over low when cooling
E05
DC link voltage is over high / low protection
E06
IPM failure
E08
Output and input water temperature different too large protection
E09
Communication error ( indoor board and outdoor board)
E10
Return water temp sensor fault
E11
Output water temp sensor fault
E12
Tank temp sensor fault
E13
Ambient temp sensor fault
E14
Evaporator temp sensor fault
E18
Compressor outlet gas temp sensor fault
E21
Compressor outlet gas temperature over high
E25
Evaporator coil temperature too high when cooling model
E31
System pressure over high protection
E32
Communication error (operation panel & indoor board)
E33
Communication error (IPM & outdoor board)
E41
System pressure over low protection
E44
Winter unit standby antifreeze protection
E45
Return gas temp sensor fault
E46
Temp sensor fault after throttle
E47
Water tank temperature sensor abnormal protection
E48
Antifreeze switch disconnect failure
d10
Gas return temperature
℃
-30
~
999
d11
After throttling temperature
℃
-30
~
999
d12
Opening of EXV(shown as the actual opening )
P
0
~
500
Pulse count
Содержание New Energy BKDX30-95I/1/S
Страница 4: ...3 BKDX50 200I 1 S BKDX60 220I 1 S BKDX80 280I 1 S...
Страница 6: ...5 3 3 BKDX80 280I 1 S 1521 5 1556 5 587 592 620 104 2 964 6 G1 5 G1 5 62 1507 591 8 1052...
Страница 11: ...10 2 Connection diagram 1 BKDX30 95I 1 S 2 BKDX50 200I 1 S BKDX60 220I 1 S BKDX80 280I 1 S...
Страница 13: ...12 4 Circuit diagram 1 BKDX30 95I 1 S 220V 2 BKDX50 200I 1 S BKDX60 220I 1 S 220V...