ADVERSE REACTIONS

•   Some users may experience skin irritation or hypersensitivity due to the 

electrical stimulation or electrical conductive medium (e.g., the NuFACE primer). 
The irritation can usually be reduced by using an alternate conductive medium.

•   Skin irritation and burns beneath the electrodes have been reported with the 

use of other powered muscle stimulators. If you experience skin irritation or 
burning, discontinue use immediately. 

•   If you experience a persistent headache and/or other persistent painful 

sensations during or following the use of the Trinity device, you should stop 
using the device and consult your doctor.

WARNINGS

•   Do not use over swollen, infected, or inflamed areas or skin eruptions, e.g., 

phlebitis, thrombophlebitis, broken capillaries, varicose veins, etc. 

•   Do not use in the eye area (circular muscle within the orbital rim), on the 

temples, on the mid-line of the neck (bone of neck), or in the breast or  
groin area.

•   Do not apply stimulation across your chest as the introduction of electrical 

current into the chest may cause rhythmic disturbances to your heart, which 
could be lethal. 

•   Do not use while driving, operating machinery or during any activity in which 

involuntary muscle contractions may put the user at undue risk of injury.

•   Never operate this device if it is not working properly, if it has been dropped or 

damaged, or submerged in water. 

•   Never drop or insert any object into any openings on the device. Return the 

device to NuFACE for examination and repair if you believe that the device is 
not properly working. 

•   Do not use the device when it is on the charging cradle.

•   Use of controls or adjustments, or the performance of procedures other than 

those specified herein, may result in injury. 

•   Keep all electrical appliances (including the Trinity device and treatment 

attachments) away from water (including baths, showers, and sinks). 

•  If the device begins to overheat, turn off immediately. 

•   Stop using the device immediately if you suspect the device to be 

malfunctioning, or not operating properly. 

•   Do not disassemble the device and attachment as this may cause damage, 

malfunction, electrical shock, fire or injury. There are no user-serviceable parts 
inside. 

Note: Disassembly voids the warranty.

•   Use of accessories, transducers and cables other than those specified, with the 

exception of transducers and cables sold by the manufacturer of the Trinity 
device as replacement parts for internal components, may result in increased 
emissions or decreased immunity of the system.

9

Содержание Trinity PRO

Страница 1: ...ENSURE YOUR BEST RESULTS Get the NuFACE App at myNuFACE com app facial toning device ...

Страница 2: ...nline at www myNuFACE com Please visit our website at www myNuFACE com to see the full assortment of devices treatment attachments and skin care products available for your skin care needs Thank you Carol Cole Co Founder TRINITY DEVICE FACIAL TRAINER ATTACHMENT The Trinity device is an FDA cleared multi solution skin care device innovatively designed with interchangeable treatment attachments to h...

Страница 3: ...t the purchase date 1 POWER ON OFF BUTTON 2 INTENSITY CONTROL UP 3 INTENSITY CONTROL DOWN 4 INTENSITY LEVEL INDICATOR 5 FACIAL TRAINER ATTACHMENT 6 ATTACHMENT RELEASE BUTTON 7 SOFT TOUCH GRIP 8 CHARGING CRADLE 9 SPHERE 10 EXTERNAL POWER ADAPTER NOT SHOWN 11 SPEAKER NOT SHOWN a Ascending beep Device is turning on b Descending beep Device is turning off c Single beep Move to a new position on face T...

Страница 4: ...hizate Disodium EDTA Polysorbate 20 WRINKLE REDUCER ATTACHMENT NOT INCLUDED Red LED treatment attachment FDA cleared for the treatment of full face wrinkles Delivers a precise combination of red amber and infrared lights to naturally reduce the appearance of fine lines and wrinkles ELE ATTACHMENT NOT INCLUDED Targeted microcurrent treatment attachment FDA cleared for facial stimulation Gently stim...

Страница 5: ...e with an oil free cleanser Men should shave before treatment as facial hair can interfere with the conductivity of the spheres Note Any make up and or oil based products left on the skin can block the penetration of microcurrent 3 Ensure that you have no allergic reaction to the NuFACE primer before proceeding Refer to Before Using Your Device 4 Apply the NuFACE primer section by section as you t...

Страница 6: ...re to the side of the nose both spheres should be on the nasolabial fold Slowly glide to the hairline at the upper ear until the beep sounds 5 seconds DO NOT PLACE THE SPHERES IN THE EYE AREA GLIDE ALONG THE ORBITAL BONE Return to Position 1 and repeat series 2 more times FOREHEAD 1 THICK OF BROW Place both spheres horizontally above the thick of the eyebrow Slowly glide upward to the hairline unt...

Страница 7: ...on skin type and skin damage Most users experience instant facial stimulation benefits while others take longer Best results are achieved with regular use ADVANCED TREATMENT HOLDS OPTIONAL These optional holds are stationary and isolate the delivery of microcurrent do not glide Select the holds that target your area s of concern Lift and hold each position for 1 2 beeps 5 10 seconds JAW Under jawl...

Страница 8: ...ries and should be recycled or disposed of per state and local guidelines Do not dispose of this product which contains NiMH Li Ion batteries in fire TROUBLESHOOTING If your Trinity device is not turning on please make sure all of the following are true The Trinity device is completely secured to the attachment and fits snugly Make sure to firmly press the attachment release button on the back of ...

Страница 9: ...d epilepsy when there is a tendency to hemorrhage following acute trauma or fracture over areas of the skin which lack normal sensation A slight tingling sensation may occur while using the Facial Trainer Lowering the intensity may reduce or eliminate this sensation There may be a perception of flashing lights during the use of your Facial Trainer resulting from the stimulation of your optic nerve...

Страница 10: ...ery or during any activity in which involuntary muscle contractions may put the user at undue risk of injury Never operate this device if it is not working properly if it has been dropped or damaged or submerged in water Never drop or insert any object into any openings on the device Return the device to NuFACE for examination and repair if you believe that the device is not properly working Do no...

Страница 11: ...ed warranties of merchantability or fitness for a particular purpose are limited in duration to the duration of this warranty Some states do not allow limitations on how long an implied warranty lasts so the above limitation may not apply to you Repair or replacement of the product is the exclusive remedy available to the consumer under this warranty NuFACE shall not be liable for any incidental o...

Страница 12: ...0 days we recommend at least 5 times per week after 60 days or once desired results are achieved 2 3 times per week for maintenance following the instructions in the User Manual Can I use my favorite skin care products with the Facial Trainer YES The Facial Trainer works synergistically with many skin care lines However do not use oil based skin care products prior to your microcurrent treatment a...

Отзывы: