CAUTION
& SAFETY
READ THE ENTIRE MANUAL BEFORE OPERATING THE FAN. Ensure that all safety practices and instructions are followed during the installation, operation and servicing of the fan. Failure to
apply these safety practices could result in death or serious injury. If you do not understand the instructions please call our Technical department for guidance.
The fan installation should follow the recommendations outlined in this manual. MacroAir is not responsible for any injury or damage to people or property as a result of not complying with the
recommendations outlined in this manual.
IMPROPER ELECTRICAL INSTALLATION CAN CAUSE DAMAGE TO THE FAN AND INTERFERE WITH OTHER ELECTRONIC EQUIPMENT. IN ADDITION TO STANDARD ELECTRICAL SAFETY
CONSIDERATIONS, PLEASE OBSERVE THE FOLLOWING:
•
THE WIRING FROM THE CONTROL PANEL TO THE FAN MOTOR MUST BE MACROAIR-SUPPLIED SHEILDED CABLE.
•
SEPARATE INCOMING POWER AND MOTOR CONTROL CABLES BY A MINIMUM OF (6) INCHES.
•
RUN WIRING FOR EACH FAN SEPARATELY.
•
DO NOT ATTEMPT TO CONTROL MULTIPLE FANS WITH ONE CONTROL PANEL.
•
ALWAYS GROUND PROPERLY. CONNECT THE SUPPLIED CABLE GLANDS TO EACH END OF THE MOTOR CONTROL CABLE AND TIGHTEN THEM SECURELY AT BOTH THE FAN MOTOR
AND CONTROL PANEL ENDS. CONNECT THE GROUND BAR IN THE CONTROL PANEL TO GROUND AT THE MAIN BREAKER BOX.
•
PLEASE REFER TO THE INSTALLATION INSTRUCTIONS FOR MORE INFORMATION.
All fan controls should only be installed by qualified technicians familiar with the requirements of the NEC and local codes. Refer to appropriate portions of this manual for other important
requirements. Failure to follow these guidelines will void the manufacturer’s warranty.
NOTICE:
All electrical controls are configured at the factory and are ready to use. No user adjustments are available. Follow the included wiring schematics and installation instructions when installing
this device to ensure proper operation. Do not make any changes to any part of the motor control panel without first consulting MacroAir.
Installation is to be in accordance with the national electrical code, ANSI/NFPA 70-1999 and local codes.
HAZARD OF ELECTRIC SHOCK, EXPLOSION, OR ARC FLASH
Read and understand this manual before installing or operating
a fan unit. Installation, adjustment, repair, maintenance must be
performed by qualified personnel.
The user is responsible for compliance with all international and
national electrical code requirements with respect to grounding of
all equipment.
Many of the parts of this unit operate at line voltage. DO NOT
TOUCH.
Install all covers before applying power or starting and stopping
the unit.
DAMAGED EQUIPMENT
Do not operate or install any fans or fan accessories that appear to be damaged.
Failure to follow this instruction can result in death, serious injury, or equipment damage.
MAINTENANCE AND SERVICE:
If the fan does not operate properly using the procedures in this manual, BE CERTAIN TO REMOVE ALL POWER TO THE
UNIT and contact our technical department for futher assistance.
Keep all body parts clear of moving part at all times.
All electrical troubleshooting and repair must be done by a qualified technician and meet all applicable codes.
Содержание AIRSPAN
Страница 2: ...2 2015 MacroAir Technologies 1 800 347 9575 www nueraheat com...
Страница 11: ...2015 MacroAir Technologies 1 800 347 9575 www nueraheat com 11 FAN MOUNTING...
Страница 23: ...2015 MacroAir Technologies 1 800 347 9575 www nueraheat com 23 CONTROL PANEL SCHEMATICS...
Страница 28: ...28 2015 MacroAir Technologies 1 800 347 9575 www nueraheat com...
Страница 29: ...2015 MacroAir Technologies 1 800 347 9575 www nueraheat com 29 GUY WIRE INSTALLATION...
Страница 33: ...2015 MacroAir Technologies 1 800 347 9575 www nueraheat com 33 BLADE INSTALLATION...