Installation
•
19
The internal voltage is -5V or -10V which can is selected by JP1 of ACL-
8112DG/HG or JP8 of ACL-8112PG. The possible configurations are
specified as Figure 2.9. Note that the internal reference voltage is used
only when the JP2 of ACL-8112DG/HG or JP6 nd JP7 of ACL-8112PG is
set to internal reference.
Reference Voltage is
-5V (default setting)
JP1 /
JP8
-10V
-5V
Reference Voltage is
-10V
JP1 /
JP8
-10V
-5V
Figure 2.9 Internal Reference Voltage Setting
2.12 A/D Input Range Setting
(This section is for ACL-8112PG only)
The A/D input range of ACL-8112PG can be set to
±
5V or
±
10V by jumper
JP9.