Warranty Information

Immunity test

80 MHz to 2.5

GHz

3A/m

3A/m

survey,a should be less than the 

compliance level in each frequency range.b

Interference may occur in the vicinity of 

equipment marked with the following 

symbol:

NOTE 1       At 80 MHz and 800 MHz, the higher frequency range applies.

NOTE 2       These guidelines may not apply in all situations. Electromagnetic propagation is 

affected by absorption and reflection from structures, objects and people.

Field strengths from fixed transmitters, such as base stations for radio (cellular/cordless) 

telephones and land mobile radios, amateur radio, AM and FM radio broadcast and TV 

broadcast cannot be predicted theoretically with accuracy. To assess the electromagnetic 

environment due to fixed RF transmitters, an electromagnetic site survey should be 

considered. If the measured field strength in the location in which the Digital Blood Pressure 

Monitor is used exceeds the applicable RF compliance level above, the Digital Blood 

Pressure Monitor should be observed to verify normal operation. If abnormal performance is 

observed, additional measures may be necessary, such as reorienting or relocating the 

Digital Blood Pressure Monitor.

Radiated RF

IEC 61000-4-3

IEC 60601 test  Compliance 

level

level

Electromagnetic environment - guidance

                                Recommended separation distances between 

portable and mobile RF communications equipment and the Digital Blood Pressure Monitor. 

output power 

of transmitter

For transmitters rated at a maximum output power not listed above, the recommended 

separation distance d in metres (m) can be estimated using the equation applicable to the 

frequency of the transmitter, where P is the maximum output power rating of the transmitter 

in watts (W) according to the transmitter manufacturer.

Separation distance 

 (m)

according to frequency of transmitter

Pressure Monitor is intended for use in an electromagnetic environment in which radiated 

RF disturbances are controlled. The customer or the user of the Digital Blood Pressure 

Monitor can help prevent electromagnetic interference by maintaining a minimum distance 

between portable and mobile RF communications equipment (transmitters) and the Digital 

Blood Pressure Monitor as recommended below, according to the maximum output power 

of the communications equipment.

80 MHz to 800 MHz

0.117

0.233

0.369

0.738

1.167

2.333

3.689

7.379

11.667

23.333

80 MHz to 800 MHz

0.01

0.1

1

10

100

Содержание BA2110

Страница 1: ...Model No BA2110 VER A00...

Страница 2: ...t 4 5 IHB Introduction 6 Before Taking A Measurement 7 Quick Reference Guide 8 Battery lnstallation Replacement 9 Adjusting Settings 10 Proper Use of the Arm Cuff 11 12 Take a Measurement 13 Use the M...

Страница 3: ...or moderate injury to the user or patient or damage to the equipment or other property Read all information in the instruction manual and any other literature included in the box before using the unit...

Страница 4: ...ff A new arm cuff does not include an air plug Please continue to use the old air plug on the new arm cuff Hose Air Plug Insert to Air Socket Metal Arm Cuff Warning 1 Do not use rechargeable batteries...

Страница 5: ...d bathing for 30 minutes before taking a measurement 2 Stress raises blood pressure Avoid taking measurements during stressful times 3 The cuff can be applied to your left or right wrist Always measur...

Страница 6: ...tive polarities match the polarities of the battery compartment as indicated Remove the battery cover from the battery compartment Replace the battery cover Press the START STOP button All symbols app...

Страница 7: ...heart 3 Remove all clothes from your upper arm allowing the cuff to fit directly on the skin 2 Make sure the air plug is inserted properly in the main unit 1 10 Press the MEM button about 10 seconds u...

Страница 8: ...3 The blood pressure and pulse rate are displayed when the measurement completed All display symbols appear on the screen The cuff starts to inflate automatically Press the START STOP button 1 Measur...

Страница 9: ...d to save the latest measurement value when more than 60 sets The unit also calculates an average reading based on the values of the latest 3 times measurement taken To delete the memory value In the...

Страница 10: ...nts the blood pressure produced by relaxation of the heart muscle Blood Circulation 17 About Blood Pressure Note When a person s systolic and diastolic pressures fall into different categories the hig...

Страница 11: ...ve your arm and body and keep quiet Error Indicators 18 The following symbol will appear on the display when measuring abnormally 19 Care and Maintenance Do not clean the body and cuff with naphtha th...

Страница 12: ...c and heart rate from the upper arm by using the oscillometric method The unit is intended for usingin only adult population not applied to the other populations such as neonatal baby It can t be used...

Страница 13: ...60601 1 2 Medical electrical equipment Part 1 2 General requirements for basic safety and essential performance Collateral standard Electromagnetic compatibility Requirements and tests EN1060 1 Non in...

Страница 14: ...1000 4 8 6 kV contact 8 kV air 6 kV contact 8 kV air 3A m 3A m Floors should be wood concrete or ceramic tile If floor are covered with synthetic material the relative humidity should be at least 30 P...

Страница 15: ...be necessary such as reorienting or relocating the Digital Blood Pressure Monitor Radiated RF IEC 61000 4 3 IEC 60601 test Compliance level level Electromagnetic environment guidance Recommended sepa...

Отзывы: