Installation Manual

1.2 Important Information

This manual contains important information on the safe and 
appropriate assembly, transport, commissioning, operation, 
maintenance, disassembly and simple troubleshooting of the product.

While the product has been manufactured according to the accepted 
rules of current technology, there is still a danger of personal injury or 
damage to equipment if the following general safety instructions and 
the warnings contained in these instructions are not complied with.

Read these instructions completely and thoroughly before 
working with the product.

Keep these instructions in a location where they are accessible 
to all users at all times.

Always include the operating instructions when you pass the 
product on to third parties.

1.3 Personal Protective Equipment

The following minimum Personal Protective Equipment (PPE) is 
recommended when interacting with Nuaire product:

Protective Steel Toed Shoes - 

when handling heavy objects.

 

Full Finger Gloves (Marigold PU800 or equivalent) - 

when 

handling sheet metal components. 

Semi Fingerless Gloves (Marigold PU3000 3DO or equivalent) 

- when conducting light work on the unit requiring tactile 
dexterity. 

Safety Glasses

 - when conducting any cleaning/cutting operation 

or exchanging filters. 

Reusable Half Mask Respirators 

- when replacing filters which 

have been in contact with normal room or environmental air.

Nuaire would always recommend a site specific risk assessment by a 
competent person to determine if any additional PPE is required. 

2.0 INTRODUCTION

The Nuaire SVTC8 unit comprising fan/motor assembly shall be 
certified for high temperature operation at 400°C for 2 hours. The 
range shall have been type tested to EN12101-3. 

The units shall be either 2 speed or inverter driven providing, low speed 
for day to day environmental ventilation and one off operation for 
emergency ventilation (S1 duty).

The Nuaire SVTC8 unit shall have an inlet guard for safety purposes and 
also to prevent debris being sucked through the fan.

EN12101-3 compliant.

2.1 Code Description:

SVTC8 - 50 T8 G

     |            |    | |   |

     1           2   34  5

1. Range:   

 

Induction Centrifugal Fans, 400°C for   

   2 

hrs

2. Performance Size:  

50 = 50N 

   100 

100N

3. Motor Speed: 

 

No Affix = Single Speed (Suitable For   

   Frequency 

Inverter) 

   T 

Speed

4. Motor Poles: 

 

No Affix = 4 Pole   

 

 

 

 

 

8 = 8 Pole

5. Electrical Motor Details: 

No Suffix = 400V / 50Hz 

 

 

 

G = 460V / 60Hz 

 

 

 

J = 380V / 60Hz

Inlet

Discharge

Unit Airflow Directions

3.0 DELIVERY & HANDLING

All equipment is inspected prior to despatch and leav

es the fa

ctory in 

good condition. Upon receipt of the equipment an inspection should 
be made and any damage indicated on the delivery note. Particulars of 
damage and/or incomplete delivery should be endorsed by the driver 
delivering the goods before offloading by the purchaser. 

No responsibility will be accepted for damage sustained during the 
offloading from the vehicle or on the site thereafter. All claims for 
damage and/or incomplete delivery must be reported to Nuaire within 
two days of receipt of the equipment.

Always handle the units carefully to avoid damage and distortion. If 
mechanical aids are used to lift the unit, spreaders should be employed 
and positioned so as to prevent the slings, webbing etc. making contact 
with the casing.

Содержание SVTC8

Страница 1: ...urer its service agent or similarly qualified persons in order to avoid a hazard Precautions must be taken to avoid the back flow of gases into the room from the open flue of gas or other fuel burning appliances This appliance should not be used by children or persons with reduced physical sensory or mental capabilities or lack of experience and knowledge unless they have been given supervision or...

Страница 2: ... competent person to determine if any additional PPE is required 2 0 INTRODUCTION The Nuaire SVTC8 unit comprising fan motor assembly shall be certified for high temperature operation at 400 C for 2 hours The range shall have been type tested to EN12101 3 The units shall be either 2 speed or inverter driven providing low speed for day to day environmental ventilation and one off operation for emer...

Страница 3: ...e below states the main characteristics of the SVTC8 fan range certified for operation at 400 c for 2 hours The unit Is thermally uninsulated May be located in the smoke reservoir Is dual purpose i e suitable for day to day operation and one off emergency use Suitable for mounting in horizontal orientation only 4 1 Fitting Unit to Ceiling Raise the SVTC8 unit up into the chosen mounting position U...

Страница 4: ... with EN12101 3 2015 Note the requirements for maintenance of the motor Failure to comply with the recommendations will invalidate any warranty claim For good EMC engineering practice any sensor cables or switched live cables should not be placed within 50mm of other cables or on the same metal cable tray as other cables 6 1 Wiring Electrical supply wiring connection is to an externally mounted is...

Страница 5: ...eed of the motor supplied by the mains and that the delivered power corresponds to the previous definitions These qualifications ensure the qualification of the driven fan by the manufacturer Maintenance Constraints Regular service visits must be performed on the installation AT LEAST EVERY 6 MONTHS incorporating the following checks i Checking insulation resistance R 100 MOhms 500V DC If the drai...

Страница 6: ...ons The remaining two years covers replacement parts only This warranty is void if the equipment is modified without authorisation is incorrectly applied misused disassembled or not installed commissioned and maintained in accordance with the details contained in this manual and general good practice The product warranty applies to the UK mainland and in accordance with Clause 14 of our Conditions...

Страница 7: ...01 09 21 Document Number 671711 7 Nuaire Western Industrial Estate Caerphilly CF83 1NA nuaire co uk NOTES 7 ...

Страница 8: ...ovision for support 4 3 Flanges and connection spigots are provided for the purpose of joining to duct work systems They must not be used to support the ductwork 4 4 Local Environment Humidity Ambient humidity the humidity at the unit s installed location shall be within the range 10 to 95 for controls non condensing Air humidity the humidity of the air passing through the unit shall be within the...

Отзывы: