NuAire SINGLEPAK SP125 Скачать руководство пользователя страница 5

Installation and Maintenance  

SINGLEPAK IN LINE FAN

5

230v 
50Hz
1 ph AC
supply

L

N

L2

N

N

L1

Fan unit

Singlepak with  Auto transformer 
speed control types: 
SPCON-1.5  SPCON-3.5  SPCON-7.5

Not suitable for use with
the following units:      
SP/QSP200
SP/QSP200H
SP/QSP250

Motor

L

N

L

N

230v 
50Hz
1 ph AC
supply

L

N

L2

N

L1

Fan unit

Singlepak with  Electronic 
speed control types: 
ESC1-3A   ESC1-6A   ESC1-10A 

Motor

L

N

L

N

Note on Speed Controls:

A list of setting instructions is supplied 
with each Speed Control unit.

Содержание SINGLEPAK SP125

Страница 1: ... mounting used is the total responsibility of the installer Note that the unit is supplied with flange holes see fig 1 The mounting feet supplied can be attached at any of these points and the unit may be installed at any angle Installation Units should always be positioned with sufficient space to allow removal of the access covers and subsequent removal of fan and motor assemblies etc Note when ...

Страница 2: ...mperature safety cut out rated 13amps Manual reset button located on integral terminal box Constructed from galvanised steel Can be installed at any angle The filter medium is non woven synthetic fibres which are resistant to moisture fungus bacteria and frost Cover retained by quick release toggle clips Constructed from galvanised steel Fitted with a gasket liner X D Q SP125 Q SP200 Q SP200H Q SP...

Страница 3: ... the terminal block provided in the terminal box inside the casing If a control other than NuAires is being installed the design of suitable circuitry is the responsibility of others ESC1 electronic type SP CON transformer type Dims A B C ESC1 3A 83 88 180 ESC1 6A 115 95 195 ESC1 10A 115 95 195 ESC1 3A illustrated SPCCON7 5 illustrated Dims weights A B C kg SP CON 1 5 115 85 180 1 70 SP CON 3 5 20...

Страница 4: ... on rise of temperature simple manual reset from external push button Unit and Run on Timer Singlepak Heaters Single phase single stage SH 100 SH 125 SH 200 SH 250 Motor L N L N SL L N N L T1 T2 L N E L N 230v 50Hz 1 ph AC supply Typical stage switching by others To Heater control circuit by others NB Singlepak Heatwers 3 Phase For 3 phase multi stage wiring information please telephone NuAire Tec...

Страница 5: ...pes SPCON 1 5 SPCON 3 5 SPCON 7 5 Not suitable for use with the following units SP QSP200 SP QSP200H SP QSP250 Motor L N L N 230v 50Hz 1 ph AC supply L N L2 N L1 Fan unit Singlepak with Electronic speed control types ESC1 3A ESC1 6A ESC1 10A Motor L N L N Note on Speed Controls A list of setting instructions is supplied with each Speed Control unit ...

Страница 6: ...ment is the fan motor assembly due to a failed motor or dam aged impeller In either eventuality the complete fan motor assembly must be removed from the unit case NOTE BEFORE COMMENCING WORK ELECTRICALLY ISOLATE THE TWINPAK UNIT AND OR THE ASSOCIATED NUAIRE CONTROL IF FITTED FROM THE MAINS SUPPLY Remove the access cover Disconnect the incoming wiring from the connection box located inside case Sup...

Страница 7: ...ity and Safety of Electrical Equipment Designation of machinery SINGLE IN LINE FAN Machinery Types SINGLEPAK QIUET SINGLEPAK SP QSP Relevant EC Council Directives 89 336 EEC 92 31 EEC EMC 73 23 EEC 93 68 EEC Low Voltage Directive Applied Harmonised Standards EN55014 1 EN55014 2 EN60204 1 EN60335 2 80 Basis of Self Attestation Quality Assurance to BS EN ISO 9001 BSI Registered Firm Certificate No F...

Страница 8: ... installation accessories are supplied with the specified equipment eg wall mounting brackets They are to be used to support the equipment only Other system components must have separate provision for support 4 3 Flanges and connection spigots are provided for the purpose of joining to ductwork systems They must not be used to support the ductwork 5 0 INSTALLATION REQUIREMENTS In addition to the p...

Отзывы: