Rectangular spigots 
(size NALTF 18-24)

Circular  
spigots 
(NALTF 9-17)

D dia

Removable top
panel

Figure 2. NALTF and NALTRF-1 Units Dimensions

A

B

Removable 
top panel

Opposed
outlet
grilles

F

E

Control module
located internally

Bottom inlet

C

Louvred
end outlet

Bottom rectangular 
inlet spigot

F

E

B

A

C

Spigot

Unit

A

B

C

E

F

NALTRF9 to NALTRF10

974

974

622 

457

229

NALTRF11 to NALTRF12

1233

1233

701

762

304 

NALTRF13 to NALTRF17

1430

1635

796

889

381

Unit

A

B

C

D dia

F

NALTF9-10,

NALTRF9-10 

974

974

622

400

-

-

NALTF11-12, 

NALTRF11-12 

1233

1233

701

500

-

-

NALTF13-17,

NALTRF13-17 

1430

1635

796

630

-

-

NALTF18-24,

NALTRF18-24 

2030

2313

1183

-

1200

700

Rect Spigot 

Unit

A

B

C

E

F

NALTRF18 to NALTRF24

2030

2313

1183

1200        700

Figure 1. Lifting unit with slings

via spreaders.

Figure 3. NALTRF Bottom Inlet Units Dimensions

Figure 4. NALTRF Larger Bottom/End Inlet Units Dimensions

1

15. 05. 17. Leaflet Number 671269

NALTF & NALTRF

Belt Drive Roof and Plantroom Twinfans

Installation and Maintenance

The EMC Directive 

2014/30/EU 

 

The Low Voltage 

directive 

2014/35/EU

2.0 Dimensions

Introduction

The Nuaire NALTF and NALTRF Belt Drive Twinfan range

consists of the following units:

NALTF/NALTRF Plantroom/Roof in line mounted unit.

NALTRF Plantroom/Roof bottom inlet unit. 

NALTRF Plantroom/Roof bottom/end inlet unit . 

(Larger sizes).

Units are rectangular in section and the casing is 

manufactured from heavy gauge ‘Aluzinc’ aluminium-zinc

coated mild steel.

A full size internally lined access panel is fitted to the top

face and is fully detachable for inspection purposes. 

The motor plate and frames are supported on the base by

resilient mountings allowing the fan unit to be operated 

without the need for separate anti vibration fan case 

mountings. 

The units incorporate two independent motors with high 

efficiency, forward curved centrifugal impellers running in

metal scrolls.  Taperlocked pulleys and wedge drive belts are

employed. The fans discharge into a common outlet chamber

through a shutter system that prevents ‘blowback through

the standby fan. The motors are manufactured to BS5000

and are suitable for  three phase supply. 

Airflow and failure monitors are standard for sizes 9 to 15.

All motors have Class F insulation and are suitable for 

operation in ambient temperatures up to 40

o

C. 

1.0 Handling

Always handle the units carefully to avoid damage and 

distortion. Eyebolts are provided on some units for lifting. 

If mechanical aids are  used to lift the unit, spreaders should 

be employed and positioned so as

to prevent the slings, webbing etc. 

making contact with the

casing.  

Correctly position slings 

to avoid twisting of the 

unit case and observe 

the centre of gravity 

before the final lift is 

made

. Note: the weight 

of the unit from the 

rating plate.

Nuaire: A Trading Division of Polypipe Limited  

Western Industrial Estate

 

Caerphilly  United Kingdom  CF83 1NA  

T: 029 2088 5911  F: 029 2088 7033  E: [email protected]  W: www.nuaire.co.uk

Содержание NALTF Series

Страница 1: ...sing is manufactured from heavy gauge Aluzinc aluminium zinc coated mild steel A full size internally lined access panel is fitted to the top face and is fully detachable for inspection purposes The motor plate and frames are supported on the base by resilient mountings allowing the fan unit to be operated without the need for separate anti vibration fan case mountings The units incorporate two in...

Страница 2: ...d of mounting used is the total responsibility of the installer The lower edge of the casing has an internal skirt allowing the unit to be located on an upstand or prefabricated curb if desired The units must be securely screw fixed to the upstand curb to prevent vibration and or wind damage It is the installers responsibility to drill the case to provide access for the electrical cables Care shou...

Страница 3: ...TRF 9 15 and NALTF 9 15 only Controls for NALTF NALTRF 9 15 The NALTF NALTRF 9 15 fan units incorporate an integral auto changeover controller which provides 12 hour duty share operation and automatic selection of the standby fan should the duty fan fail Fault indication to an external device is provided via volt free contacts of a relay Note the relay is energised when no fault is present Note It...

Страница 4: ...kg Changing a Drive Belt To replace a belt remove the two bolts from the motor mounting furthest from the fan and slacken the remaining two bolts Lift the motor plate and remove the belt Replacing the belt is the reverse of this procedure Figure 12 Adjusting the Drive Belts larger units Adjusting Drive Belt Tension larger units All belt drive units incorporate belt tensioning devices To adjust the...

Страница 5: ... of the part required 7 0 Warranty The unit has a one year warranty The warranty starts from the date of delivery and covers faulty materials or workmanship and includes parts and labour The labour element is subject to full free and safe access to the equipment as recommended by the CDM regulations This warranty is void if the equipment is modified without authorisation is incorrectly applied mis...

Страница 6: ...s given for the individual product the following general requirements should be noted 5 1 Where access to any part of equipment which moves or can become electrically live are not prevented by the equipment panels or by fixed installation detail eg ducting then guarding to the appropriate standard must be fitted 5 2 The electrical installation of the equipment must comply with the requirements of ...