2

28. 07. 21. Document Number  671856

Nuaire | 

Western Industrial Estate 

Caerphilly 

CF83 1NA 

|

 

nuaire.co.uk

MRXBOXAB-ECO(3/5)-(SC/SW)

Installation Manual

2.0 INTRODUCTION

The ECO(3/5) wall mounted range of units is designed to provide 
mechanical supply and extract ventilation with heat recovery. 

The unit is fitted with two independent fans. Each fan has full speed 
control for background and boost ventilation rates. To recover heat 
from the extract air the heat exchanger block is utilised. The heat 
exchanger can recover up to 95% of the normally wasted heat. Bypass 
operation can be disabled via a manual switch in colder months so the 
unit recovers heat continually.

3.0 MECHANICAL INSTALLATION

Installation must be carried out by competent personnel in accordance 
with the appropriate authority and conforming to all statutory 
governing regulations. All mains wiring must be in accordance with the 
current I.E.E. Regulations, or the appropriate standards. Ensure that the 
mains supply (Voltage, Frequency and Phase) complies with the rating 
label. 

Please note a clear working space is required around the installed unit 
to allow the cover to be removed and provide sufficient access for 
maintenance such as filter change.

Please allow a minimum of 360mm in front of an  
MRXBOXAB-ECO(3/5) unit.

The fan must be installed indoors, on a suitable wall away from direct 
sources of frost, heat and water spray or moisture generation. For a 
vibration-free result the unit must be mounted to a solid wall.

The unit must remain switched on at all times to maintain 
ventilation within the dwelling. Turning the unit off will cause long 
term damage to the unit and building fabric.

 

Airflow Through unit (Standard Unit)

Extract air 
from house

Intake air 

Exhaust air 

from outside

to outside

from house

to house

Supply air 

Intake air 
from outside

Extract air 
from house

Supply air 
to house

Exhaust air 
from house
to outside

Airflow Through OH unit (Opposite Hand Unit)

Extract air 
from house

Intake air 

Exhaust air 

from outside

to outside

from house

to house

Supply air 

Intake air 
from outside

Extract air 
from house

Supply air 
to house

Exhaust air 
from house
to outside

3.1 Wall Mounting

If fitting the MVHR in conjunction with a MRXBOX-AV(3/5) the 
hanging brackets supplied with the MVHR are redundant and 
should not be used. The installation instructions supplied with 
MRXBOX-AV(3/5) should be followed. 

The unit is designed for wall mounting, only on a solid wall. A 
gypsum block or stud/plasterboard wall will not suffice.

1. One part of the mounting bracket (supplied) should be offered up 

to the wall, ensuring it’s located horizontally. Mark the fixing points 
through the pre drilled holes in the bracket and install with screws 
(by others), whilst ensuring the interlock side is at the top (Figure 3).

2. Install the unit on the wall by ensuring the bracket fixed to the rear 

of the unit interlocks over the wall mounted bracket (Figure 4).

Care must be taken to ensure the unit is installed true in all 3 
dimensions. Failure to do so may result in overflow from the 
internal condensation drip tray.

Wall Mounting Bracket

Mounting Unit Onto Bracket

3.1.1 Option 1 - Solid Wall

The MVHR unit fixed to a solid wall construction using the 

mounting bracket provided.

 

Ducting in the 

ceiling void.

Side view of unit 

mounted on the

block wall in a 

cupboard.

MVHR-DRAIN

Condensate drain,

uninsulated drain 

pipe with min 5

o

fall running to SVP.

Valve in ceiling.

Solid Wall Mounted Unit Installation

Содержание MRXBOXAB-ECO3-OHSW

Страница 1: ... or instruction concerning the safe use of the appliance by a person responsible for their safety Children shall not play with the appliance Cleaning and user maintenance shall not be carried out by children 1 1 Hazard Symbols REFER TO INSTRUCTION MANUAL Read and understand the installation and maintenance manual before installing operating or maintaining this product 1 2 Important Information Thi...

Страница 2: ...e unit and building fabric 1 Airflow Through unit Standard Unit Extract air from house Intake air Exhaust air from outside to outside from house to house Supply air Intake air from outside Extract air from house Supply air to house Exhaust air from house to outside 2 Airflow Through OH unit Opposite Hand Unit Extract air from house Intake air Exhaust air from outside to outside from house to house...

Страница 3: ...uld be positioned on a 25mm minimum thickness MDF panel that is vertically fixed across the roof trusses to form a solid false wall Add additional vertical supports if necessary Use the Anti vibration tray assembly MRXBOX AV 3 5 including the angle brackets to be purchased separately 8 Angled Brackets Loft Mounted Installation 3 3 Off Site Cupboard Construction For off site constructed cupboards a...

Страница 4: ...led taut A maximum of 300mm should be used on each leg To prevent condensation on the outside of the outside air inlet duct and the air outlet duct from the unit these ducts should be insulated Ducting must be installed in such a way that resistance to airflow is minimised Bends should be kept to a minimum A minimum distance of 300mm between the appliance and any bends in ductwork is recommended I...

Страница 5: ... as follows The maximum whole dwelling extract ventilation rate e g boost should be at least the greater of step 1 and step 2 Note that the maximum individual room extract rate should be at least those given in ADF 2010 Extract Ventilation Rates table The minimum air supply rate should be at least the whole building ventilation rate found in step 1 For Scotland refer to BRE Digest 398 For further ...

Страница 6: ... Air Valve mounted unit Nuaire wall MVHR DRAIN Condensate drain uninsulated drain pipe with min 5o fall running to SVP Insulated extract duct 3 10 2 Rectangular Ducting 14 Typical Rectangular Ducting Arrangement For Wall Mounted Units Exhaust air from kitchen bathroom to outside via air brick Minimum distance as specified in building regulations Intake air from outside via air brick All duct betwe...

Страница 7: ...connected to the underside of the MVHR unit within The cable should be fed through rubber blanking plug to provide a seal when the cover is re fitted 4 3 Wiring Diagrams 4 3 1 Unit Serving Kitchen And Bathroom 16 Wiring Diagram Unit Serving Kitchen And Bathroom ECO3 3A Fuse BS 1362 ECO5 5A Fuse BS 1362 MAINS 230V 50Hz Light Room Light Switch Double Pole N L 3 Pole Isolator Kitchen Switch Blue Brow...

Страница 8: ... to solely boost the unit Additional switch should be used local to the wet rooms Section 4 3 3 5 2 Status Indication The status of the unit is indicated by a series of LED s on the front cover The variants are listed below The display on the unit control panel will not indicate when a higher speed setting has been triggered by an external source such as an ES PIR2 etc 20 Unit Control On Front Pan...

Страница 9: ...ulations and guidelines taking into account all site based risks 9 0 AFTER SALES AND REPLACEMENT PARTS For technical assistance or further product information including spare parts and replacement components please contact the After Sales Department If ordering spares please quote the serial number of the unit together with the part number if the part number is not known please give a full descrip...

Страница 10: ...10 28 07 21 Document Number 671856 Nuaire Western Industrial Estate Caerphilly CF83 1NA nuaire co uk MRXBOXAB ECO 3 5 SC SW Installation Manual NOTES ...

Страница 11: ...11 28 07 21 Document Number 671856 Nuaire Western Industrial Estate Caerphilly CF83 1NA nuaire co uk MRXBOXAB ECO 3 5 SC SW Installation Manual NOTES ...

Страница 12: ...12 28 07 21 Document Number 671856 Nuaire Western Industrial Estate Caerphilly CF83 1NA nuaire co uk MRXBOXAB ECO 3 5 SC SW Installation Manual NOTES ...

Отзывы: