The EMC Directive

 

2014/30/EU

The Low Voltage 
Directive

2014/35/EU

MRXBOXAB-ECO-LP1SW (Standard Unit)
MRXBOXAB-ECO-LP1-OHSW (Opposite Hand Unit)

Mechanical Ventilation Unit with Heat Recovery for 
Ceiling Void Mounting

Installation and Maintenance

Spigot 3.

Spigot 2.

Spigot 1. 

Spigot 4.

Figure 1.   Airflow through unit (Standard Configuration)

Spigots 1 to 4

1. Intake Air (Fresh air from outside).
2. Supply Air (Supply in to house).
3. Extract Air (Warm stale air from house).
4. Exhaust Air (Waste air to oustide).

Spigot 1.

Spigot 4.

Spigot 3. 

Spigot 2.

Figure 2.   Airflow through unit (Opposite Handing)

Spigots 1 to 4

1. Intake Air (Fresh air from outside).
2. Supply Air (Supply in to house).
3. Extract Air (Warm stale air from house).
4. Exhaust Air (Waste air to oustide).

1.0 INTRODUCTION

The LP1 ceiling void mounted unit is designed to provide mechanical 
supply and extract ventilation with heat recovery and incorporates HX 
bypass.

The unit is fitted with two independent fans. Each fan has full speed 
control for background and boost ventilation rates. To recover heat 
from the extract air the heat exchanger block is utilised. The heat 
exchanger can recover up to 80% of the normally wasted heat.

IMPORTANT

The unit must remain switched on at all times to maintain ventilation 

within the dwelling. Turning the unit off will cause long term damage to 

the unit and building fabric. 

This appliance is not intended for use by persons (including children) with 

reduced physical, sensory or mental capabilities, or lack of experience 

and knowledge, unless they have been given supervision or instruction 

concerning the use of the appliance by a person for their safety. Children 

should be supervised so that they do not play with the appliance.

2.0 INSTALLATION

Installation must be carried out by competent personnel in accordance 
with the appropriate authority and conforming to all statutory 
governing regulations. All mains wiring must be in accordance with the 
current I.E.E. Regulations, or the appropriate standards. Ensure that the 
mains supply (Voltage, Frequency and Phase) complies with the rating 
label.

Please note a clear working space is required around the installed unit 
to allow the cover to be removed and provide sufficient access for 
maintenance such as filter change.

The fan must be installed indoors, in a suitable ceiling void away from 
direct sources of frost, heat, water spray or moisture generation. For a 
vibration-free result the unit must be mounted to a solid surface in the 
void.

The unit is designed for ceiling mounting only (Horizontal surface).

The unit is supplied with a steel mounting bracket.

Position & secure the steel bracket to the ceiling using appropriate 
fixings (supplied by others), ensuring that the two outer fixing holes on 
the unit are accessible (see fig. 2).

Note: The mounting bracket should be on the same side as the 
condensate take off.

3. The unit can now be offered into position & located into the 
mounting bracket.

4. Using appropriate fixings (supplied by others) fix the unit to the 
ceiling. It is recommended that the unit is fixed through three holes on 
the non-bracket side and the two outer holes on the bracket side.

Note: The unit must be installed in an upright position as shown for 
the condensate drain and for compliance with safety regulations 
relating to IP protection for water drip ingress.

Steel mounting bracket

Figure 3. Installing the unit using appropriate fixing bolts  
(shown on standard unit).

IMPORTANT

Isolation - Before commencing work, make sure that the unit, switched 

live and Nuaire control are electrically isolated from the mains supply and 

switched live supply.

Содержание MRXBOXAB-ECO-LP1-OHSW

Страница 1: ...that they do not play with the appliance 2 0 INSTALLATION Installation must be carried out by competent personnel in accordance with the appropriate authority and conforming to all statutory governing...

Страница 2: ...pipe cutter 2 Remove any swarf from the end of the plastic pipe Ream the copper pipe end to remove any burr and file if necessary to remove any external sharp edges Mark the socket depth on the pipe a...

Страница 3: ...imum high rate from Table 1 For sanitary accommodation only as an alternative the purge ventilation provisions given in ADF 2010 can be used where security is not an issue In this case minimum high ex...

Страница 4: ...1 2 3 735 Filter access distance Removable access filter Removable access filter 69 96 4 342 Required working space Supply air to lounge via in ceilings Air Valve Extract air from kitchen via in ceil...

Страница 5: ...mper 1 2 3 735 Filter access distance Removable access filter Removable access filter 69 96 4 342 Required working space Supply air to lounge via in ceilings Air Valve Extract air from kitchen via in...

Страница 6: ...only as the connections above are factory fitted Connection to Remote Fail Indicator Ref MRXBOX95 RFI optional Fuse 2A MAINS 230V 50Hz light Room Light switch Double Pole N L 3 Pole isolator Kitchen...

Страница 7: ...Intake and extract temperatures are monitored at the point the airflows enter the unit if the range falls within the set parameters the bypass damper is opened automatically to target an indoor comfo...

Страница 8: ...on planned maintenance being undertaken This warranty is void if the equipment is modified without authorisation is incorrectly applied misused disassembled or not installed commissioned and maintaine...