Unit must not be switched off during normal operation, the

product is designed to run continuously.

Nuaire Limited

Western Industrial Estate  Caerphilly  United Kingdom  CF83 1NA  

T: 029 2085 8400  F: 029 2085 8444  E: [email protected]  W: www.nuaire.co.uk

1

 

24. 

0

1

. 1

7

. Leaflet Number 671500

MRXBOX95B-LH1/LH2

Mechanical Ventilation Unit with Heat Recovery 

& Summer Bypass for Loft Mounting

Installation and Maintenance

Spigot 2.

Spigot 1.

Spigot 3.

Spigot 4.

21.5mm Condensate drain 

outlet. Optional either side.

M20 & M16 Cable 

Glands. Mains entry 

and Blanking Gland.

Controls

Figure 1. Airflow through unit.

The EMC Directive 

2004/108/EC  

The Low Voltage 

Directive 

2006/95/EC

Two fixing brackets 

should be attached 

on the non-control 

end of the unit via  

the two lower hole 

positions. 

(see figure 2c).

Two fixing brackets 

should be attached 

on the control end of 

the unit via the two 

upper hole positions. 

(see figure 2c).

Figure 2a. Mounting MRXBOX95B-LH1/LH2 onto roof joists using

the ‘L’ shaped fixing brackets and AV mounts with four suitable

screws on the long side of the unit. 

Spigot Location and Ducting references: 

Spigot 1.

Extract air from kitchen/

bathroom.

Spigot 2.

Intake air from outside. 

Spigot 3.

Outside air to house. 

Spigot 4.

Extract air to outside.

1.0 Introduction

MRXBOX95B-LH1/LH2 is designed to provide mechanical

supply and extract ventilation with heat recovery and 

incorporates summer bypass. 

The unit has the facility to commission the supply and extract

fans independently on minimum speed (continuous background

ventilation), boost control will control both fans to the same

volume. 

To recover heat from the extract air the heat exchanger block 

is utilised. This heat exchanger can recover up to 95% of the

normally wasted heat.

The bypass damper opens when a 230V switch signal is

applied to the unit (via a manual switch). This opens the

damper via a wax actuator. When the switch signal is 

de-activated the unit returns to its original state (air through 

the heat exchanger).

Outside air supplied through the bypass is still being filtered,

so the air quality is optimal, irrespective of the bypass setting

(Open or closed).

2.0 Installation

Installation must be carried out by competent personnel in

accordance with the appropriate authority and conforming

to all statutory governing regulations.

All mains wiring must be in accordance with the current I.E.E.

Regulations, or the appropriate standards. Ensure that the

mains supply (Voltage, Frequency and Phase) complies with

the rating label.

Please note a clear working space is required around the

installed unit to allow the cover to be removed and provide 

sufficient access for maintenance such as filter change.

The fan must be installed indoors, away from direct sources of

frost, heat, water spray or moisture generation. 

The unit is designed for mounting on the roof joists in the loft

space using four “L shape” metal brackets and four A.V.

mounts supplied with the unit. Please note that various 

positions for the brackets are available to suit different joist

centres.

Connect the four ‘L’ shape fixing brackets to the unit with the 

M4 screws (provided) they can be attached to the long, or

short sides of the unit depending on requirements. Each pair of

brackets should be mounted at different heights so the fall is

towards the drip tray end of the unit. (see figures 2a, 2b and

2c for fixing details). Lower the unit with the “L” shape fixing

brackets attached onto the joists.  Mark through the brackets

and drill four clearance holes into the top surface of joists.

Locate anti-vibration mounts (supplied) above and below each

bracket fixing point hole and, using 4 suitable screws (not 

provided) and washers, fix the unit to the joists (see fig 2b). 

Do not overtighten the fixings. The distance from the top

washer on the A.V. mount to the joist when installed must

not be less than 30mm.

Содержание MRXBOX95B-LH2

Страница 1: ...switch This opens the damper via a wax actuator When the switch signal is de activated the unit returns to its original state air through the heat exchanger Outside air supplied through the bypass is...

Страница 2: ...MVHR DRAIN outlet and slide the cap and rubber seal onto the pipe 4 Insert the pipe end fully into the socket 5 Slide the rubber seal and screwed cap up against the face of the socket and tighten the...

Страница 3: ...larly supply and extract air grilles should be at least 300mm apart Figure 4 Typical MVHR ducted arrangement for a loft mounted unit using the Nuaire condensation trap 125mm dia CONTRAP 125 Nuaire CON...

Страница 4: ...m spigot 450 VIEW FROM TOP Condensate drain alternative position 21 5mm dia condensate drain 21 5mm dia condensate drain alternative position SIDE VIEW non controls 3 0 Dimensions mm Figure 6 Filter F...

Страница 5: ...ce with current IEE wiring regulations See fuse rating MAINS 230V 50Hz Room light Light switch Double Pole N L 3 Pole isolator Kitchen switch Green yellow Blue Brown Black Summer bypass switch Grey on...

Страница 6: ...de of the unit to allow access for maintenance purposes 1 Replace filters every 5 years Remove the top cover and slide out the two G4 filters fitted either side of the heat exchanger Replace with new...

Страница 7: ...eing affected 3 2 When handling the equipment care should be taken with corners and edges and that the weight distribution within the unit is considered Lifting gear such as slings or ropes must be ar...

Страница 8: ...8 24 01 17 Leaflet Number 671500 Western Industrial Estate Caerphilly United Kingdom CF83 1NA T 029 2085 8400 F 029 2085 8444 E info nuaire co uk W www nuaire co uk...

Отзывы: