MRXBOXAB-ECO3B-1Z(H)SW & MRXBOXAB-ECO5B-1Z(H)(SC/SW)

Installation Manual

2.0 INTRODUCTION

The ECO(3/5)B-1Z wall mounted range of units are designed to offer 
improved sound levels and an aesthetically pleasing installation by 
housing a Mechanical Ventilation with Heat Recovery unit (MVHR) and 
attenuator inside an acoustically lined enclosure. 

The MVHR unit is fitted with two independent fans. Each fan has full 
speed control for background and boost ventilation rates. To recover 
heat from the extract air the heat exchanger block is utilised. The heat 
exchanger can recover up to 95% of the normally wasted heat.

Bypass operation can be disabled via a manual switch in colder months 
so the unit recovers heat continually.

Airflow Through unit (Standard Unit)

Intake air 

from outside

Extract air 

from house

to house

Supply air 

Exhaust air 

from house

to outside

Extract air 

from house

Intake air 

Exhaust air 

from outside

from house

to outside

Supply air 

to house

 

Airflow Through OH unit (Opposite Hand Unit)

Intake air 

from outside

Extract air 

from house

to house

Supply air 

Exhaust air 

from house

to outside

Extract air 

from house

Intake air 

Exhaust air 

from outside

from house

to outside

Supply air 

to house

3.0 MECHANICAL INSTALLATION

Installation must be carried out by competent personnel in accordance 
with the appropriate authority and conforming to all statutory 
governing regulations. All mains wiring must be in accordance with the 
current I.E.E. Regulations, or the appropriate standards. Ensure that the 
mains supply (Voltage, Frequency and Phase) complies with the rating 
label. 

Please allow a minimum of 360m in front of an  
MRXBOXAB-ECO(3/5)B unit.

The fan must be installed indoors, on a suitable wall away from direct 
sources of frost, heat and water spray or moisture generation. For a 
vibration-free result the unit must be mounted to a solid wall.

The unit must remain switched on at all times to maintain 
ventilation within the dwelling. Turning the unit off will cause long 
term damage to the unit and building fabric.

3.1 Transport Fixings

To prevent damage during transportation the product is shipped with 
securing fixings, these can be found front and centre of the enclosure 
top panel (Figure 3). These must be removed before use, failure to do so 
will result in excessive vibration and noise. The screws removed can be 
discarded and replaced with rubber caps provided.

 

Transport Fixings

Spigot fixing plate

Transportation fixings

3.2 Wall Mounting

The unit is designed for wall mounting on a solid wall only, a 
gypsum block/plasterboard wall will not suffice. 

Examples of suitable installation are shown overleaf. The wall brackets 
supplied should be secured to the wall using suitable fixings (supplied 
by others) as per the dimensions given in figure 4. The head of the 
chosen fixing should protrude no more than 8mm from the wall 
bracket. The enclosure assembly can then be lifted using suitable 
equipment and moved into position so it is sitting directly on the wall 
brackets (ensuring the rear panel of the enclosure is not in contact 
with the wall bracket fixings). The enclosure can be secured to the wall 
brackets using the 4x M8 fixings supplied.

No part of enclosure should be in contact with the building structure, 
the only components that should be in contact are the wall mounting 
brackets.

Care must be taken to ensure the unit is installed true in all 3 

dimensions. Failure to do so may result in overflow from the 

internal condensation drip tray. 

Wall Bracket Installation Dimensions

25

25

704 crs

9.1 dia.

30

94

94

33

Содержание MRXBOX-ECO-AE

Страница 1: ...cerning the safe use of the appliance by a person responsible for their safety Children shall not play with the appliance Cleaning and user maintenance shall not be carried out by children 1 1 Hazard...

Страница 2: ...ont of an MRXBOXAB ECO 3 5 B unit The fan must be installed indoors on a suitable wall away from direct sources of frost heat and water spray or moisture generation For a vibration free result the uni...

Страница 3: ...ing the wall MVHR DRAIN brackets Condensate drain uninsulated drain pipe with min 5o fall running to SVP Valve in ceiling Unit weight 76kG 3 3 Condensate Drain The MVHR unit inside the enclosure is fi...

Страница 4: ...s 1 2 13 17 21 25 29 Notes 1 In addition the minimum ventilation rate should be no less than 0 3 l s per m of internal floor area This includes all floors e g for a two story building add the ground...

Страница 5: ...is advisable that if the installation and building works are complete the unit is left running If the building works are not complete please close the air valves or cover up the air valves to prevent...

Страница 6: ...ted drain pipe with min 5 o fall running to SVP MVHR unit Nuaire MVHR DRAIN Condensate drain uninsulated drain pipe with min 5 o fall running to SVP 3 9 2 Rectangular Ducting 13 Typical Rectangular Du...

Страница 7: ...And Bathroom 15 Wiring Diagrams Unit Serving Kitchen And Bathroom ECO3 3A Fuse BS 1362 ECO5 5A Fuse BS 1362 MAINS 230V 50Hz Light Room Light Switch Double Pole N L 3 Pole Isolator Kitchen Switch Blue...

Страница 8: ...rom the wet rooms When the unit senses that the humidity exceeds the set point the unit will boost to that set by the commissioned boost speed The set point can be found behind the front of the unit F...

Страница 9: ...e a full description of the part required The serial number will be found on the identification plate attached to the unit casing Telephone 02920 858 400 aftersales nuaire co uk Technical or commercia...

Страница 10: ...10 19 11 21 Document Number 672009 Nuaire Western Industrial Estate Caerphilly CF83 1NA nuaire co uk MRXBOXAB ECO3B 1Z H SW MRXBOXAB ECO5B 1Z H SC SW Installation Manual NOTES...

Страница 11: ...11 19 11 21 Document Number 672009 Nuaire Western Industrial Estate Caerphilly CF83 1NA nuaire co uk MRXBOXAB ECO3B 1Z H SW MRXBOXAB ECO5B 1Z H SC SW Installation Manual NOTES...

Страница 12: ...12 19 11 21 Document Number 672009 Nuaire Western Industrial Estate Caerphilly CF83 1NA nuaire co uk MRXBOXAB ECO3B 1Z H SW MRXBOXAB ECO5B 1Z H SC SW Installation Manual NOTES...

Отзывы: