3
10. 12. 21. Document Number 672010
Nuaire | Western Industrial Estate | Caerphilly | CF83 1NA | nuaire.co.uk
MR-ECO-COOL-V
Installation Manual
2.0 HANDLING
Offloading and positioning of the equipment is the responsibility of
the purchaser. Items should only be lifted by competent personnel
following appropriate risk assessment.
Cooling Module Weighs 65Kg. Appropriate manual handling
assessments must be conducted before work can commence.
Combined weight of MRXBOXAB-ECO5-AE(OH)CV and Cooling
module = 121 kg. Lifting of assembled Cooling MVHR
should be carried out with genie-lift or similar with assembly being
supported from below.
The cooling module is supplied with a lifting point and a lifting
eyelet. This is for the lifting the cooling module ONLY and should
NOT be used to lift the assembled Cooling MVHR.
Once the Cooling Module has been positioned and secured in place
with the side and top brackets, replace the lifting eyelet with the
supplied plug to ensure the unit is sealed.
1
Airflow Through Unit
STANDARD HAND
OPPOSITE HAND
Condensate Drain
Condensate Drain
EXHAUST
TO
O
UTSIDE
IN
TAKE FRO
M
OUTSIDE
EXTRACT FROM
HO
M
E
SUPPLY TO
HO
USE
EXTRACT
FROM
HO
M
E
SUPPLY TO
HO
USE
EXHAUST
TO
O
UTSIDE
IN
TAKE FRO
M
OUTSIDE
3.0 DIMENSIONS
COOLING MODULE
(MR-ECO-COOL-V)
(SUPPLIED)
MVHR UNIT
(MRXBOXAB-ECO5-AECV)
(AVAILABLE SEPARATELY)
ECO5-AE-1Z-STND
(AVAILABLE SEPARATELY)
Front View
MR-ECO-COOL-V
CONTROLS
(SUPPLIED)
(Standard Hand)
DIGITAL ROOM THERMOSTAT
(CM-THERM-CONTROL)
(SUPPLIED)
SUMMER/WINTER SWITCH
(AVAILABLE SEPARATELY)
Side fixing plate
(X2 supplied)
150mm Spigot
Condensate Drain Position
(Standard Hand)
Top Fixing Brackets
(Standard Hand)
Power Cord
(4M Approx.)
Top bracket reversed fixing
holes for opposite handed installation
458
140
140
51
4
(c
ov
er
s)
14
4
Cooling Module lifting point
(lifting point to be used to lift
cooling module ONLY)
22
7
14
4
738 (cover)
52
65
3
71
6
39
5
150 Spigot
57
11
61
170
225
90.0
92
95
29
86
.0
86.0
10
13
69
16mm (min) Back Box
Not supplied
2
Fully Assembled Dimensions