2
16. 10. 20. Document Number 670901
Nuaire |
Western Industrial Estate
|
Caerphilly
|
CF83 1NA
|
nuaire.co.uk
FLAT2000 L/R
Installation Manual
1.2 Important Information
This manual contains important information on the safe and
appropriate assembly, transport, commissioning, operation,
maintenance, disassembly and simple troubleshooting of the product.
While the product has been manufactured according to the accepted
rules of current technology, there is still a danger of personal injury or
damage to equipment if the following general safety instructions and
the warnings contained in these instructions are not complied with.
•
Read these instructions completely and thoroughly before
working with the product.
•
Keep these instructions in a location where they are accessible
to all users at all times.
•
Always include the operating instructions when you pass the
product on to third parties.
1.3 Personal Protective Equipment
The following minimum Personal Protective Equipment (PPE) is
recommended when interacting with Nuaire product:
•
Protective Steel Toed Shoes -
when handling heavy objects.
•
Full Finger Gloves (Marigold PU800 or equivalent) -
when
handling sheet metal components.
•
Semi Fingerless Gloves (Marigold PU3000 3DO or equivalent)
- when conducting light work on the unit requiring tactile
dexterity.
•
Safety Glasses
- when conducting any cleaning/cutting operation
or exchanging filters.
•
Reusable Half Mask Respirators
- when replacing filters which
have been in contact with normal room or environmental air.
Nuaire would always recommend a site specific risk assessment by a
competent person to determine if any additional PPE is required.
2.0 INTRODUCTION
The Nuaire Drimaster / Flatmaster range has been curing severe
condensation problems for over 20 years in some of the worst affected
properties throughout the world. Its successful operation depends
entirely upon the unit being installed strictly in accordance with these
instructions. We would, therefore, respectfully suggest that you read
through this guide in its entirety before commencing installation
and then go through this guide step by step to ensure a satisfactory
completion.
Units are supplied assembled and include a thermostatically controlled
heater. A unit mounted override switch is provided. A ‘BOOST’ speed
facility for additional ventilation is included, this is operated by a
remote switch (supplied).
The FLAT2000 L/R is a ‘handed’ product, with the L/R signifying the
discharge direction, as viewed from the front. The FLAT2000L unit is
supplied arranged for LEFT HAND discharge of air. The FLAT2000R unit
is supplied arranged for RIGHT HAND discharge of air.
Whilst the installation of the unit may be achieved by a suitable
craftsman, the provision of the electrical supply and the connection
of the unit to the mains must be carried out by a qualified
electrician.
3.0 MECHANICAL INSTALLATION
Installation must be completed by competent persons, in accordance
with good industry practice and should conform to all governing and
statutory bodies i.e. IEE, CIBSE, etc.
Where the systems are installed in flats, ensure all regulatory provisions
are adhered to. Where the systems are installed in flats where these
regulatory provisions do not apply, good installation practice should be
observed.
For more information please refer to the Building Regulations,
Approved Document B (Fire safety) – Volume 1: Dwelling houses (2006
Edition).
The unit is designed to take fresh air from outside, clean the air, and
discharge it into the central hallway via a system of ducting supplied by
the installer.
This unit is
NOT
suitable for ceiling mounting.
The dwelling supply grille is usually installed at high level in a central
location within the hallway, although discharging the air down the
length of the hallway (away from the front door) should also prove
acceptable. Unit performance may be enhanced if an existing heat
source can warm the discharged air e.g. by locating the discharge grille
above a radiator.
Before commencing installation decide the best position for the unit
and where the fresh air is to come from and be discharged to. The unit
can be installed in many different configurations and is supplied with
enough interchangeable spigots to enable it to be used with either
circular (100mm) or rectangular ducting (121mm x 60mm).
The heater outlet MUST NOT be left exposed. A minimum distance
of 500mm is required between the discharge grille and the heater.
500mm
‘Blank off’
plate
Inlet position
Alternative
inlet position
Heater
Discharge grille
Right hand
Flatmaster unit
1
Typical Installation Of Right Handed Unit (FLAT2000R) With
Top Discharge
3.1 Setting Up The Correct Airflow Direction
3.1.1 Fitting The Deflector Plate
Ensure the deflector plate is fitted correctly into scroll cover as
appropriate for the handing of the unit (Figures 2 & 3). Once fitted
the assembly can be slotted into the scroll and clipped firmly in place
(Figure 4).
2
Fitting Deflector Plate For FLAT2000L
Deflector
plate
position
under
scroll
cover
Deflector plate
pinched between guide
posts as shown
Deflector plate
shown fitted in
left hand air discharge
Deflector plate shown fitted for left hand
air discharge (viewed from inside).
Scroll
cover