21. 10. 16. Leaflet Number 671169
Installation and Maintenance
ECOSMART Squrbo Fans
'Net' connection for
Ecosmart devices
RUN FAULT
N
E
L
SL
DP
CL
N
R
E
T
DAMPER
HEAT
DEMAND
Remove link if switched live signal,
an enabler or BMS signal is connected
Damper connection
Heat demand signal
Run signal
Fault signal
Connection for ES - CO
2
0 - 10V BMS Signal
L N E
Mains connection
230V 50Hz 1 phase
Heater temperature
setting range 15 - 30 C
'Net' connection for
Ecosmart devices
RUN FAULT
N
E
L
SL
DP
CL
N
R
E
T
DAMPER
HEAT
DEMAND
Remove link if switched live signal,
an enabler or BMS signal is connected
Damper connection
Heat demand signal
Run signal
Fault signal
Connection for ES - CO2
0 - 10V BMS Signal
Mains connection
230V 50Hz 1 phase
Wiring
Figure 4. ESS1 - 5 LPHW and Extract.
Figure 5. ESS1 - 5E (Electric Coil).
Connections
to Damper
F
A
UL
T R
UN
N
L
SL
DP
CL
N
RET
Remove this link wire if:
1. a switched live signal is connected.
2. A ES-PIR, ES-TC or BMS signal
is connected.
NET connections for
ECOSMART devices
Min Max SL run on
Trickle
Test
0
1
Pwr
Standby
Fan 1
Fan 2
Heating
Cooling
Fault
Frost
Tx
Rx
Ecosmart
Heat demand
signal
L
N
E
230V 50Hz
1ph mains
Earth
Run signal
Fault signal
HEA
T D
AMPER
DEMAND
0V
0-10V
BMS signal
Speed
Controller
Connections
to Damper
F
A
UL
T R
UN
N
L
SL
DP
CL
N
RET
Remove this link wire if:
1. a switched live signal is connected.
2. A ES-PIR, ES-TC or BMS signal
is connected.
NET connections for
ECOSMART devices
Min Max SL run on
Trickle
Test
0
1
Pwr
Standby
Fan 1
Fan 2
Heating
Cooling
Fault
Frost
Tx
Rx
Ecosmart
Heat demand
signal
L
N
E
230V 50Hz
1ph mains
Earth
Run signal
Fault signal
HEA
T D
AMPER
DEMAND
Set air off
temperature.
of LPHW COIL
0V
0-10V
BMS signal
Speed
Controller
Connections
to Damper
F
A
UL
T R
UN
N
L
SL
DP
CL
N
RET
Remove this link wire if:
1. a switched live signal is connected.
2. A ES-PIR, ES-TC or BMS signal
is connected.
NET connections for
ECOSMART devices
Min Max SL run on
Trickle
Test
0
1
Pwr
Standby
Fan 1
Fan 2
Heating
Cooling
Fault
Frost
Tx
Rx
Ecosmart
Heat demand
signal
L3
L2
L1
N
E
400V 50Hz
3ph +N mains
supply for fan
and heater
Earth
Run signal
Fault signal
HEA
T D
AMPER
DEMAND
Adjustment for air off temperature.
Do not set temperature above
30
O
C
Electric heater control
0V
0-10V
BMS signal
Speed
Controller
Figure 6. ESS6 and ESSE6 (No Heater).
Figure 7. ESS6 - L (LPHW Coil).
Figure 8. ESS6 - E (12kW Electric Coil).