NuAire DS1A-EES Скачать руководство пользователя страница 3

3

24. 02. 22. Document Number  671679

Nuaire | Western Industrial Estate | Caerphilly | CF83 1NA | nuaire.co.uk

DAVE Supply (DS)

Installation Manual

4.0 DIMENSIONS (mm) & WEIGHTS (kg)

 

Dia.

A

K

B
L

C

J

H

G

Removable 
weatherproof 
control cover

Airflow
direction

DAVE Supply Unit Dimensions

Unit Code

A

B

C

'D' 

Dia.

G

H

J

K

L

Weight (kg)

DS1A-NES(H)

1005

559

233

150

370

150

100

960

609

30

DS1A-LES(H)

1005

559

233

150

430

175

190

960

609

55

DS1A-EES(H)

1005

559

233

150

430

155

155

960

609

50

DS2A-NES(H)

1005

696

300

200

370

150

100

960

746

40

DS2A-LES(H)

1005

696

300

200

430

175

190

960

746

60

DS2A-EES(H)

1005

696

300

200

430

155

155

960

746

50

DS2HA-NES(H)

1005

696

300

200

370

150

100

960

746

40

DS2HA-LES(H)

1005

696

300

200

430

175

190

960

746

60

DS2HA-EESH)

1005

696

300

200

430

155

155

960

746

50

DS3A-NES(H)

1005

780

345

200

370

150

100

960

830

45

DS3A-LES(H)

1005

780

345

200

430

175

190

960

830

65

DS3A-EES(H)

1005

780

345

200

430

155

155

960

830

55

DS4A-NES(H)

1005

840

370

250

370

150

100

960

890

50

DS4A-LES(H)

1005

840

370

250

430

175

190

960

890

70

DS4A-EES(H)

1005

840

370

250

430

155

155

960

890

60

DS4HA-NES(H)

1005

840

370

250

370

150

100

960

890

70

DS4HA-LES(H)

1005

840

370

250

430

175

190

960

890

70

DS4HA-EES(H)

1005

840

370

250

430

155

155

960

890

60

DS5A-NES(H)

1155

984

410

315

370

150

100

1110

1034

75

DS5A-LES(H)

1155

984

410

315

430

175

190

1110

1034

105

DS5A-EES(H)

1155

984

410

315

430

155

155

1110

1034

90

DS6A-NES(H)

1155

1092

455

400

370

150

100

1110

1142

80

DS6A-LES(H)

1155

1092

455

400

430

175

190

1110

1142

110

DS6A-EES(H)

1155

1092

455

400

430

155

155

1110

1142

90

DS7A-NES(H)

1155

1200

500

400

370

150

100

1110

1250

95

DS7A-LES(H)

1155

1200

500

400

430

175

190

1110

1250

120

DS7A-EES(H)

1155

1200

500

400

430

155

155

1110

1250

105

Removable Weatherproof Control Cover

Unit Code

Width

Height

Depth

DS(1-7)A-NES(H)

470

173

120

DS(1-2)A-LES(H)

649

183

216

DS(3)A-LES(H)

649

243

256

DS(4)A-LES(H)

649

251

256

DS(5-7)A-LES(H)

649

323

281

DS(1-7)A-EES(H)

530

178

175

Содержание DS1A-EES

Страница 1: ...minating close to the fan must be adequately protected by suitable guards This appliance should not be used by children or persons with reduced physical sensory or mental capabilities or lack of exper...

Страница 2: ...sizes with a maximum duty of 1 1m3 s 1100l s Units are manufactured from aluzinc rectangular in section and have circular rigid spigots at each end All units are supplied with fixing brackets designe...

Страница 3: ...5 DS3A EES H 1005 780 345 200 430 155 155 960 830 55 DS4A NES H 1005 840 370 250 370 150 100 960 890 50 DS4A LES H 1005 840 370 250 430 175 190 960 890 70 DS4A EES H 1005 840 370 250 430 155 155 960 8...

Страница 4: ...the pump when the 2 Port PICV is closed It is recommended that all joints are checked for leaks when commissioning and a strainer and isolating valves are fitted by others for ease of maintenance The...

Страница 5: ...4 00 5 2 2 DS3 DS4 DS4H DN25 L h L s GPM 20 340 0 094 1 50 25 425 0 118 1 88 30 510 0 142 2 25 35 595 0 165 2 63 40 680 0 189 3 00 45 765 0 213 3 38 50 850 0 236 3 75 55 935 0 260 4 13 60 1020 0 283 4...

Страница 6: ...e mains supply 6 1 Unit Details Unit details including Full Load Current Voltage fan speed etc can be found on the unit label 6 2 Wiring Diagrams Local isolator by others All inter connections between...

Страница 7: ...e Western Industrial Estate Caerphilly CF83 1NA nuaire co uk DAVE Supply DS Installation Manual 6 2 3 DS1 4 with Electric Heating 9 Wiring DS1 4 with Electric Heating 6 2 4 DS5 7 with Electric Heating...

Страница 8: ...power any external equipment the installer must provide adequate fusing or other protection These contacts are rated at 5A resistive 0 5A inductive Run Connections Contacts are closed when the fan is...

Страница 9: ...50 9 75 10 00 Only available on relevant unit 7 0 MAINTENANCE Isolation Before commencing work make sure that the unit and Nuaire control are electrically isolated from the mains supply It is importan...

Страница 10: ...F C A B D B G C 17 Unit Components No Heater 18 Unit Components LPHW Heater A B A E D B A B C A E D B F C A B A E D B G C 19 Unit Components Electric Heater A B A E D B B A D C A B A E D B G C 8 0 WAR...

Страница 11: ...components can be segregated into mixed plastic and widely recycled Cardboard packaging wood used filters and other paper components can be largely recycled or fully processed in energy from waste cen...

Страница 12: ...and steps taken to prevent ingress of contaminants 4 0 OPERATIONAL LIMITS 4 1 It is important that the specified operational limits for the equipment are adhered to e g operational air temperature air...

Отзывы: