DAVE Supply (DS)

Installation Manual

9.0 END-OF-LIFE AND RECYCLING

Ensure that Nuaire product is made safe from any electrical / water 
/ refrigerant supplies before dismantling commences. This work 
should only be undertaken by a qualified person in accordance with 
local authority regulations and guidelines, taking into account all 
site based risks.

Where possible Nuaire use components which can be largely recycled 
when the product reaches its end-of-life:

Fans, motors, controls, actuators, cabling and other electrical 
components can be segregated into WEEE recycling streams.

Sheet metal parts, aluminium extrusion, heating/cooling coils and 
other metallic items can be segregated and fully recycled.

EPP, plastic ducting, nylon corner pieces, plastic heat exchangers, 
packaging material and other plastic components can be 
segregated into mixed plastic and widely recycled.

Cardboard packaging, wood, used filters and other paper 
components can be largely recycled or fully processed in energy 
from waste centres.

Remaining Items can be further segregated and processed in 
accordance with the zero waste hierarchy. Please call After Sales 
Support for further information on items not listed above.

10.0 AFTER SALES AND REPLACEMENT PARTS

For technical assistance or further product information, including spare 
parts and replacement components, please contact the After Sales 
Department.

If ordering spares please quote the serial number of the unit together 
with the part number, if the part number is not known please give a full 
description of the part required. The serial number will be found on the 
identification plate attached to the unit casing.

Telephone 02920 858 400 

[email protected]

Technical or commercial considerations may, from time to time, 

make it necessary to alter the design, performance and dimensions 

of equipment and the right is reserved to make such changes without 

prior notice.

Содержание DS1A-EES

Страница 1: ...minating close to the fan must be adequately protected by suitable guards This appliance should not be used by children or persons with reduced physical sensory or mental capabilities or lack of exper...

Страница 2: ...sizes with a maximum duty of 1 1m3 s 1100l s Units are manufactured from aluzinc rectangular in section and have circular rigid spigots at each end All units are supplied with fixing brackets designe...

Страница 3: ...5 DS3A EES H 1005 780 345 200 430 155 155 960 830 55 DS4A NES H 1005 840 370 250 370 150 100 960 890 50 DS4A LES H 1005 840 370 250 430 175 190 960 890 70 DS4A EES H 1005 840 370 250 430 155 155 960 8...

Страница 4: ...the pump when the 2 Port PICV is closed It is recommended that all joints are checked for leaks when commissioning and a strainer and isolating valves are fitted by others for ease of maintenance The...

Страница 5: ...4 00 5 2 2 DS3 DS4 DS4H DN25 L h L s GPM 20 340 0 094 1 50 25 425 0 118 1 88 30 510 0 142 2 25 35 595 0 165 2 63 40 680 0 189 3 00 45 765 0 213 3 38 50 850 0 236 3 75 55 935 0 260 4 13 60 1020 0 283 4...

Страница 6: ...e mains supply 6 1 Unit Details Unit details including Full Load Current Voltage fan speed etc can be found on the unit label 6 2 Wiring Diagrams Local isolator by others All inter connections between...

Страница 7: ...e Western Industrial Estate Caerphilly CF83 1NA nuaire co uk DAVE Supply DS Installation Manual 6 2 3 DS1 4 with Electric Heating 9 Wiring DS1 4 with Electric Heating 6 2 4 DS5 7 with Electric Heating...

Страница 8: ...power any external equipment the installer must provide adequate fusing or other protection These contacts are rated at 5A resistive 0 5A inductive Run Connections Contacts are closed when the fan is...

Страница 9: ...50 9 75 10 00 Only available on relevant unit 7 0 MAINTENANCE Isolation Before commencing work make sure that the unit and Nuaire control are electrically isolated from the mains supply It is importan...

Страница 10: ...F C A B D B G C 17 Unit Components No Heater 18 Unit Components LPHW Heater A B A E D B A B C A E D B F C A B A E D B G C 19 Unit Components Electric Heater A B A E D B B A D C A B A E D B G C 8 0 WAR...

Страница 11: ...components can be segregated into mixed plastic and widely recycled Cardboard packaging wood used filters and other paper components can be largely recycled or fully processed in energy from waste cen...

Страница 12: ...and steps taken to prevent ingress of contaminants 4 0 OPERATIONAL LIMITS 4 1 It is important that the specified operational limits for the equipment are adhered to e g operational air temperature air...

Отзывы: