6.0  Fitting the Main Fan Unit

The main fan unit is supplied with eyelets for suspension between
the roof trusses. It is the responsibility of the installer to supply and
fit suitable hanging brackets/wires (See Figure 5).

Install the unit in a position that ensures that all ducting takes the
least complex route.

The main fan unit should be positioned to ease maintenance. Please
note that a clear distance of 500 mm should be available above the
unit to allow access for maintenance.

The fan unit can also be mounted directly onto the roof joists using
an AV mounting kit available from Nuaire (Part No. 771393). 
Screw the battens (not supplied), to the unit via the 5mm dia. holes
in the base under the filters, then lower complete onto the joists.
(See Figure 6). 

Mark and drill the 12mm dia. clearance holes required in the ends of
the battens and place anti-vibration mounts above and below each
batten fixing point.  Using the four large screws and special 
washers, fix the unit to the joists. 

Do not over tighten fixings. The distance from the top washer to
the joist when installed must not be less than 50mm.

7.0  Main fan unit air outlet connection

The main fan single air outlet spigot should be connected to the 
diffuser spigot using a length of 200mm diameter insulated 
ducting and dynotie connector, both supplied by the installer.

8.0 Main fan units air inlet and 

associated sensor connections

As explained previously the unit is capable of drawing in external air
from different roof locations via three air inlet spigots each fitted
with their own low energy open/close damper. Air inlet locations
may include the following:

1.  The loft space at high level through uninsulated ducting 

supplied by the installer, (see 8.1).

2.  The loft space at low level through uninsulated ducting 

supplied by the installer, (see 8.2).

3.  Depending on the property, ONE of the following options:

a) The soffit through a grille and ducting supplied by

the installer, (see 8.3).

b) or wall grille and ducting supplied by the installer, (see 8.4).

c)  or roof tile vents by others and ducting supplied by 

the installer, (see 8.5).

The following installation materials, not supplied with the
unit, can be purchased separately by the installer direct
from Nuaire , Tel: 08705 002555.
Fax: 08705 002666. E-mail: [email protected] 

Part No 

Description

PVC 933WH

3m length of 222mm x 90mm flexible PVC ducting 
for use on soffit inlets (See 8.3). This length 
should be sufficient for 3 average installations. 

775229

128mm x 260mm soffit grille (See 8.3).

FDC 200

200mm duct connector for connecting 222 x 90 
flexible duct to 200 dia. insulated duct (See 8.3).

FB250

199 x 215 x 20mm white plastic wall grille (See 8.4).  

GB250-T200

150mm dia. pipe for wall grille (See 8.4).

541044

Dynotie Zip ties, used for connecting 200mm 
ducting to spigots. 8 off should be sufficient 
for all types of installation.

FLDI 200

5m length of 200mm dia. 

insulated

ducting. 

FLD 200

5m length of 200mm dia. 

un-insulated

ducting. 

011740

200mm dia. outlet spigot. 
For use with “Fireblock” (See figure 4).

771393

AV mounting kit (See figure 6).

Please note that Nuaire do not supply any timber for the AV
mounts or the installation of the plenum to the rear of the rafters.

Typical installation details of each of the aforementioned air inlet 
arrangements using the material above are detailed on the 
following page. The installer may use alternative materials to
those above. In these circumstances Nuaire cannot take 
responsibility for their suitability.

Installation and Maintenance

Low Energy Positive Input Ventilation Unit

Figure 6.  Fan unit shown mounted on roof joists using AV mounts.

Figure 5.  Fan unit shown suspended. 

3

Leaflet Number 671347 October 2007

Washer

3” Woodscrew

A.V. mount

A.V. 
mount

Batten 25x50

Ceiling
joist

50mm
min.

12mm
clearance
hole

Содержание DRIMASTER 365

Страница 1: ...he unit however the provision of the electrical supply and the connection of the unit to the mains supply should only be carried out by a qualified electrician The unit can be installed in a home with...

Страница 2: ...2 or more storey dwellings As can be seen Figure 2 the diffuser discharges air from all four sides along the underside of the ceiling The majority of the air is discharged through the two longer open...

Страница 3: ...ng supplied by the installer see 8 2 3 Depending on the property ONE of the following options a The soffit through a grille and ducting supplied by the installer see 8 3 b or wall grille and ducting s...

Страница 4: ...by the installer 8 3 Via the soffit through a grille and ducting supplied by the installer Installation and Maintenance Low Energy Positive Input Ventilation Unit Figure 7 Figure 8 8 4 Via a wall gril...

Страница 5: ...opriate connector block on the main unit Fit the fourth temperature sensor in a suitable location in the home Select a position unaffected directly by heating radiators or possible draughts from openi...

Страница 6: ...re the power light is on green and the status light is either green or amber If the power light is not on check the wiring and connections between the fan unit and the user control Function The user c...

Страница 7: ...lids f Reset the LED light that was flashing by i Turn the power to the unit on ii Press and hold the black push button switch on master control switch iii A number of LED patterns will show iv When...

Страница 8: ...ling the equipment care should be taken with corners and edges and that the weight distribution within the unit is considered Lifting gear such as slings or ropes must be arranged so as not to bear on...

Отзывы: